ch0
ch1
ch127
com0
Both the scanning command, ch2->com0;, and the immediate operation, niSwitch
Connect Channels VI or the niSwitch_Connect function with parameters ch2 and
com0, result in the following connection:
■
signal connected to CH2 is routed to COM0
1-Wire Dual 64×1 Multiplexer Topology
ch0
ch1
ch63
com0
ch64
ch65
ch127
com4
Both the scanning command, ch2->com0;, and the immediate operation, niSwitch
Connect Channels VI or the niSwitch_Connect function with parameters ch2 and
com0, result in the following connection:
© National Instruments