background image

CANopen

®

 is a registered Community Trademark of CAN in Automation e.V.

DeviceNet

 and EtherNet/IP

 are trademarks of ODVA.

Go!, SensorDAQ, and Vernier are registered trademarks of Vernier Software & Technology. Vernier Software & Technology 

and 

vernier.com

 are trademarks or trade dress.

Xilinx is the registered trademark of Xilinx, Inc.
Taptite and Trilobular are registered trademarks of Research Engineering & Manufacturing Inc.
FireWire

®

 is the registered trademark of Apple Inc.

Linux

®

 is the registered trademark of Linus Torvalds in the U.S. and other countries.

Handle Graphics

®

, MATLAB

®

, Simulink

®

, Stateflow

®

, and xPC TargetBox

®

 are registered trademarks, and 

Simulink Coder

, TargetBox

, and Target Language Compiler

 are trademarks of The MathWorks, Inc.

Tektronix

®

, Tek, and Tektronix, Enabling Technology are registered trademarks of Tektronix, Inc.

The Bluetooth

®

 word mark is a registered trademark owned by the Bluetooth SIG, Inc.

The ExpressCard

 word mark and logos are owned by PCMCIA and any use of such marks by National Instruments is under 

license.
The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft 

Corporation in the United States and other countries.
Other product and company names mentioned herein are trademarks or trade names of their respective companies.
Members of the National Instruments Alliance Partner Program are business entities independent from NI and have no 

agency, partnership, or joint-venture relationship with NI.

Patents

For patents covering NI products/technology, refer to the appropriate location: 

Help»Patents

 in your software, 

the

patents.txt

 file on your media, or the 

National Instruments Patent Notice

 at 

ni.com/patents

.

Export Compliance Information

Refer to the 

Export Compliance Information

 at 

ni.com/legal/export-compliance

 for the NI global trade compliance 

policy and how to obtain relevant HTS codes, ECCNs, and other import/export data.

WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS

YOU ARE ULTIMATELY RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY AND 

RELIABILITY OF THE PRODUCTS WHENEVER THE PRODUCTS ARE INCORPORATED IN YOUR SYSTEM OR 

APPLICATION, INCLUDING THE APPROPRIATE DESIGN, PROCESS, AND SAFETY LEVEL OF SUCH SYSTEM 

OR APPLICATION.
PRODUCTS ARE NOT DESIGNED, MANUFACTURED, OR TESTED FOR USE IN LIFE OR SAFETY CRITICAL 

SYSTEMS, HAZARDOUS ENVIRONMENTS OR ANY OTHER ENVIRONMENTS REQUIRING FAIL-SAFE 

PERFORMANCE, INCLUDING IN THE OPERATION OF NUCLEAR FACILITIES; AIRCRAFT NAVIGATION; AIR 

TRAFFIC CONTROL SYSTEMS; LIFE SAVING OR LIFE SUSTAINING SYSTEMS OR SUCH OTHER MEDICAL 

DEVICES; OR ANY OTHER APPLICATION IN WHICH THE FAILURE OF THE PRODUCT OR SERVICE COULD 

LEAD TO DEATH, PERSONAL INJURY, SEVERE PROPERTY DAMAGE OR ENVIRONMENTAL HARM 

(COLLECTIVELY, “HIGH-RISK USES”). FURTHER, PRUDENT STEPS MUST BE TAKEN TO PROTECT AGAINST 

FAILURES, INCLUDING PROVIDING BACK-UP AND SHUT-DOWN MECHANISMS. NI EXPRESSLY DISCLAIMS 

ANY EXPRESS OR IMPLIED WARRANTY OF FITNESS OF THE PRODUCTS OR SERVICES FOR HIGH-RISK 

USES.

Содержание PXI-1036

Страница 1: ...PXI PXI 1036 PXI 1036DC User Manual PXI 1036 PXI 1036DC User Manual December 2019 371550F 01...

Страница 2: ...port phone numbers email addresses and current events National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin Texas 78759 3504 USA Tel 512 683 0100 For further support informat...

Страница 3: ...e encouraged to try to correct the interference by one or more of the following measures Reorient the antenna of the receiver the device suffering interference Relocate the transmitter the device gene...

Страница 4: ...TLE OR NON INFRINGEMENT AND ANY WARRANTIES THAT MAY ARISE FROM USAGE OF TRADE OR COURSE OF DEALING NI DOES NOT WARRANT GUARANTEE OR MAKE ANY REPRESENTATIONS REGARDING THE USE OF OR THE RESULTS OF THE...

Страница 5: ...ependent from NI and have no agency partnership or joint venture relationship with NI Patents For patents covering NI products technology refer to the appropriate location Help Patents in your softwar...

Страница 6: ...with CompactPCI 1 6 System Controller Slot 1 6 Star Trigger Slot 1 7 Peripheral Slots 1 7 Local Bus 1 7 Trigger Bus 1 8 System Reference Clock 1 8 Chapter 2 Installation and Configuration Safety Infor...

Страница 7: ...Trigger Configuration in MAX 2 10 Using System Configuration and Initialization Files 2 10 Chapter 3 Maintenance DC Fuse Replacement PXI 1036DC Only 3 1 Service Interval 3 1 Preparation 3 1 Cleaning 3...

Страница 8: ...ed Documentation The following documents contain information that you might find helpful as you read this manual PXI 1031DC 1036DC DC Cable Kit Installation Guide CompactPCI Specification PICMG 2 0 R...

Страница 9: ...s are undamaged Inspect the inner chassis for any possible damage debris or detached components If damage appears to have been caused during shipment file a claim with the carrier Retain the packing m...

Страница 10: ...e of applications The key features of the chassis include the following Accepts 3U PXI and CompactPCI PICMG 2 0 R 3 0 modules 6 slot chassis with universal AC input and automatic voltage frequency ran...

Страница 11: ...s name stenciled on the face plate Figure 1 2 shows the rear view of the PXI 1036 Figure 1 3 shows the rear panel of the PXI 1036DC Figure 1 4 shows the bottom of the chassis both types of chassis wil...

Страница 12: ...is 1 Rear Exhaust Vents 2 AC Input 3 Power Supply Fan Exhaust 4 Chassis Ground Screw 5 AUTO HIGH Fan Speed Selector Switch 6 Rubber Foot 1 Rear Exhaust Vents 2 DC Fuse Socket 3 DC Input 4 AC Input 5 P...

Страница 13: ...C Filler Panels Optional EMC filler panel kits are available from National Instruments Rack Mount Kits A rack mount kit option is available for mounting the PXI 1036 or PXI 1036DC chassis into a 19 in...

Страница 14: ...sis The signals on the backplane P1 connectors meet the requirements of the CompactPCI specification for both peripheral and system modules Refer to Appendix A Pinouts for pinout information The PXI s...

Страница 15: ...y chained bus that connects each peripheral slot with adjacent peripheral slots to the left and right refer to Figure 1 5 For example the right local bus of slot 2 connects to the left local bus of sl...

Страница 16: ...lling System Reference Clock The PXI 1036 PXI 1036DC supplies the PXI 10 MHz system clock signal PXI_CLK10 independently to each peripheral slot An independent buffer having a source impedance matched...

Страница 17: ...ircuits Operating personnel and service personnel must not remove protective covers when operating or servicing the chassis Adjustments and service to internal components must be undertaken by qualifi...

Страница 18: ...power supply enters the front and left side of the chassis which is shown in Figure 1 1 Front View of the PXI 1036 Chassis then exits through the rear of the chassis which is shown in Figure 1 2 Rear...

Страница 19: ...an instrument rack Note You may want to remove the feet from the chassis when rack mounting To do so remove the screws holding the feet in place Connecting Safety Ground Caution The PXI 1036 PXI 1036D...

Страница 20: ...able supplied Refer to Figure 1 2 Rear View of the PXI 1036 Chassis or to Figure 1 3 Rear View of the PXI 1036DC Chassis to locate the AC inlet The power switch allows you to power on the chassis or p...

Страница 21: ...contacts part number FS4008D choice of solder cup or crimp terminals Use of UL listed AWG 10 wire is recommended maximum length 216 in Install an F30A 500 VDC 600 VAC 1 5 in 41 in 10 mm 38 mm Midget...

Страница 22: ...assis power switch is in the Off Standby position Caution To protect both yourself and the chassis from electrical hazards leave the chassis off until you finish installing the controller 2 Install th...

Страница 23: ...that the controller boots If the controller does not boot refer to your controller user manual Figure 2 4 shows a PXI controller installed in the system controller slot of a PXI 1036 PXI 1036DC chass...

Страница 24: ...5 Slide the module to the rear of the chassis making sure that the injector ejector handle is pushed down as shown in Figure 2 3 3 When you begin to feel resistance push up on the injector ejector han...

Страница 25: ...to expand it 3 If the PXI system controller has not yet been configured it will be labeled PXI System Unidentified Right click this entry to display the context menu and then select the appropriate c...

Страница 26: ...ws many combinations of PXI chassis and system modules To assist system integrators the manufacturers of PXI chassis and system modules must document the capabilities of their products The minimum doc...

Страница 27: ...t out from the chassis Service Interval Clean dust from the chassis exterior and interior as needed based on the operating environment Periodic cleaning increases reliability Preparation The informati...

Страница 28: ...xterior Cleaning Cautions Avoid getting moisture inside the chassis during exterior cleaning especially through the top vents Use just enough moisture to dampen the cloth Do not wash the front or rear...

Страница 29: ...oller slot Table A 2 shows the P2 J2 connector pinout for the System Controller slot Table A 3 shows the P1 J1 connector pinout for the star trigger slot Table A 4 shows the P2 J2 connector pinout for...

Страница 30: ...GND SERR GND 3 3 V PAR C BE 1 GND 17 GND 3 3 V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3 V FRAME IRDY GND TRDY GND 12 14 Key Area 11 GND AD 18 AD 17 AD 16 GND C...

Страница 31: ...G7 GND 15 GND PXI_BRSVA15 GND FAL REQ5 GNT5 GND 14 GND BP I O BP I O BP I O GND BP I O GND 13 GND BP I O GND V I O BP I O BP I O GND 12 GND BP I O BP I O BP I O GND BP I O GND 11 GND BP I O GND V I O...

Страница 32: ...SERR GND 3 3 V PAR C BE 1 GND 17 GND 3 3 V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3 V FRAME IRDY BD_SEL TRDY GND 12 14 Key Area 11 GND AD 18 AD 17 AD 16 GND C B...

Страница 33: ...LK10 GND 16 GND PXI_TRIG1 PXI_TRIG0 RSV GND PXI_TRIG7 GND 15 GND PXI_BRSVA15 GND RSV PXI_STAR6 PXI_LBR6 GND 14 GND RSV RSV RSV GND RSV GND 13 GND RSV GND V I O RSV RSV GND 12 GND RSV RSV RSV GND RSV G...

Страница 34: ...ND SERR GND 3 3 V PAR C BE 1 GND 17 GND 3 3 V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3 V FRAME IRDY BD_SEL TRDY GND 12 14 Key Area 11 GND AD 18 AD 17 AD 16 GND C...

Страница 35: ...XI_CLK10 GND 16 GND PXI_TRIG1 PXI_TRIG0 RSV GND PXI_TRIG7 GND 15 GND PXI_BRSVA15 GND RSV PXI_LBL6 PXI_LBR6 GND 14 GND RSV RSV RSV GND RSV GND 13 GND RSV GND V I O RSV RSV GND 12 GND RSV RSV RSV GND RS...

Страница 36: ...y your systems accuracy and reliability requirements and provides warranty sparing and calibration services to help you maintain accuracy and minimize downtime over the life of your system Visit ni co...

Страница 37: ...tions Engineers make sure every question submitted online receives an answer Software Support Service Membership The Standard Service Program SSP is a renewable one year subscription included with alm...

Страница 38: ...ake figure 2 2 filler panel installation 2 3 setting fan speed 2 2 D DC power cable 1 6 power up testing 2 4 documentation conventions used in manual ix related documentation x E EMC filler panel kit...

Страница 39: ...overview 1 7 P1 J1 connector pinouts table A 6 P2 J2 connector pinouts table A 7 pinouts A 1 P1 J1 connector peripheral slot table A 6 star trigger slot table A 4 system controller slot table A 2 P2 J...

Страница 40: ...s 1 2 optional equipment 1 5 P1 DC input connector figure 2 4 rack mount kits 1 5 rack mounting 2 3 rear view of chassis 1 4 safety ground connecting 2 3 R rack mount kits 1 5 rack mounting 2 3 relate...

Отзывы: