A-32
|
ni.com
Appendix A
Specifications
Physical
Dimensions
10.0 cm × 16.0 cm (3.9 in. × 6.3 in.)
Maximum cable length
7 m
Slot requirements
One PXI Express system slot
Compatibility
Fully compatible with the
PXI-5 Express
Hardware Specification
, Revision 1.0
Weight
0.17 kg (0.37 lb) typical
Power Requirements
Environment
Maximum altitude
2,000 m
Pollution Degree
2
Indoor use only.
Operating Environment
Ambient temperature range
0 to 55 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2. Meets MIL-PRF-28800F
Class 3 low temperature limit and
MIL-PRF-28800F Class 2 high temperature
limit.)
Operating relative humidity
10 to 90%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
Power Rail
Typical Current
Maximum Current
+3.3 V
2.5 A
3 A
+5 V
10 µA
3 mA
+12 V
750 µA
1 mA
+5 VAux
0.3 A
0.4 A
-12 V
0 A
0 A