background image

Getting Started with NI 7340/7350 Controllers and AKD Drives

|

© National Instruments

|

23

reappears, refer to the 

AKD Fault and Warning Messages Card

 that came with the 

drive for more information about the fault, including possible solutions. After 
resolving the cause of the fault, click the 

Clear Faults

 button on the toolbar again. 

Figure 19 shows the location of the 

Clear Faults

 toolbar button in the AKD 

WorkBench software.

Software Installation and Configuration

This section covers installing and configuring the software for the AKD servo drive and 
NI 7340/7350 motion controller.

Step 1: Update Firmware on the Motion Controller

Firmware is software that is loaded onto the motion controller. Firmware allows you to update 
the motion controller with new features and updates. The latest firmware is automatically 
installed on the computer when you install the latest version of NI-Motion. You must download 
the firmware to the motion controller.

Complete the following steps to download firmware to an NI motion controller:

1.

Click the MAX icon on the desktop (

), or select 

Start»All Programs»

National Instruments»Measurement & Automation

 to open MAX.

2.

Expand 

Devices and Interfaces

, and then expand 

NI Motion Devices

 in the configuration 

tree. 

3.

Select the motion controller for which you want to download firmware. An exclamation 
point on the NI 7340/7350

 

motion controller icon (

) indicates that the firmware is 

outdated and must be updated.

4.

Click the 

Firmware

 tab at the bottom of the window. An exclamation point appears for 

each firmware sector that requires an update.

5.

Click the 

Update Firmware

 button at the top of the window to update all the firmware files 

on your device.

Step 2: Configure the NI Motion Controller

Complete the following steps to configure the NI 7340/7350 motion controller for use with the 
AKD servo drive.

1.

Open MAX, if it is not already open.

2.

Expand 

Devices and Interfaces

, expand 

NI Motion Devices

, and then select the 

appropriate motion controller in the configuration tree. 

3.

Expand 

Default xxxx Settings

, and then expand the axis associated with the AKD servo 

drive.

4.

Click 

Axis Configuration

 and set 

Type

 to 

Servo

.

5.

Click 

Motion I/O Settings

 and select 

Disabled

 for the 

Forward Limit Switch

Reverse 

Limit Switch

, and 

Home Switch

.

Содержание PCI-7352

Страница 1: ...PCI 7352...

Страница 2: ...and Installation 8 Step 1 Connect and Configure the NI UMI 8 Step 2 Mount the Drive and Connect the Protective Earth 14 Step 3 Connect the NI UMI to AKD Cable to the AKD Servo Drive 15 Step 4 Connect...

Страница 3: ...ing items to get started Hardware A computer with an available PXI or PCI slot NI 7340 or NI 7350 motion controller UMI 7764 or UMI 7772 74 68 pin cable to connect your NI UMI and motion controller UM...

Страница 4: ...Visual C Microsoft Visual Basic AKD WorkBench software Figures 1 and 2 show the hardware connections using a UMI 7772 74 and UMI 7764 respectively Figure 1 UMI 7772 74 to AKD Drive Connections Host PC...

Страница 5: ...designing a basic move designing a multi axis move incorporating image and data acquisition into motion applications and working with common motion concepts such as contouring and breakpoints This doc...

Страница 6: ...ing steps to install the NI Motion driver software 1 Insert the NI Motion CD into the CD ROM drive to display the NI Motion installation screen 2 If you have autorun enabled autorun exe runs automatic...

Страница 7: ...e reverse order 6 Plug in and power on the chassis PCI Controllers 1 Power off and unplug the computer Caution To protect yourself and the computer from electrical hazards the computer must remain unp...

Страница 8: ...to the network using DHCP If DHCP is not available the controller connects to the network with a link local IP address Tip You can connect a monitor to the PXI to display startup messages such as the...

Страница 9: ...your VIs on the host and then download them to the remote system when you are ready All you need to change is the board ID in your VI from the locally assigned Board ID to the ID assigned by the remot...

Страница 10: ...Connector 25 pin DSUB connector containing encoder limit and home sensor signals UMI 7772 74 Control Connector 15 pin DSUB connector containing drive command and drive enable signals X8 10 Pin Connec...

Страница 11: ...Active Low Table 1 UMI 7772 74 to AKD Drive Cable Screw Terminal Pinout Pin Signal Name 1 Forward Limit 2 Home 3 Reverse Limit 4 COM 5 24 V OUT 6 COM 7 NC 8 NC 9 NC 10 Digital Ground 11 5 V Output 12...

Страница 12: ...e AKD servo drive 4 Connect the positive lead of the 24 V external power supply to the V terminal and the negative lead to the C terminal then connect the V terminal to the Viso terminal and the C ter...

Страница 13: ...n the NI 7340 7350 motion controller and the Motion I O connector on the UMI 7764 2 Connect the UMI 7764 to AKD Drive cable to the UMI 7764 by connecting the leads from the cable to the correct screw...

Страница 14: ...olarity configuration for the AKD servo drive Inhibit Input S2 Active High Inhibit Output S1 Active Low The UMI 7764 DIP switch configuration is shown in Figure 7 Figure 7 UMI 7764 Inhibit Input and I...

Страница 15: ...n the drive BP4 BP3 BP2 BP1 GND 5 V TRIG4 TRIG3 TRIG2 TRIG1 ASSY186343A 01 UMI 7764 FWDLIM1 HOME1 REVLIM1 INHIN1 GND AOUT1 AOGND INHOUT1 STEP CW 1 DIR CCW 1 5 V GND ENCA1 ENCA1 ENCB1 ENCB1 INDEX1 INDE...

Страница 16: ...vo drive Refer to Figure 9 for the location of the connectors Figure 9 AKD Servo Drive Connectors 1 24 V Supply STO X1 2 Motor Brake X2 3 AC Input Power X3 4 Encoder Emulation X9 5 Drive Grounding Lug...

Страница 17: ...ect the 24 V power supply terminal to the 24V connection on the X1 3 pin connector 2 Connect the 24 V power supply return terminal to the GND connection on the X1 3 pin connector The X1 connector is c...

Страница 18: ...ower supply to the UMI 7764 to AKD cable Figure 6 shows the UMI 7764 to AKD Drive Cable 24V power supply leads Note Do not plug in or turn on the 24 V power supply until after you complete Step 7 Conn...

Страница 19: ...he STO and 24V wires are internally connected in the UMI 7774 to AKD cable You must insulate the STO wire if you disconnect it from the X1 connector 2 Connect the STO terminal and GND terminal to the...

Страница 20: ...r the location of the connectors 1 Connect the motor 6 pin connector to the AKD servo drive X2 motor connector Note The X2 connector also provides connection for the drive to control the 24 V holding...

Страница 21: ...g these terminals Note Do not turn on AC power until after you complete Step 7 Connect the Drive Communication in the NI UMI and AKD Servo Drive Configuration and Installation section Figure 13 shows...

Страница 22: ...ips and Troubleshooting section for instructions about direct connection using a static IP address 1 Set S1 and S2 on the drive to 0 to configure the drive for DHCP mode The drive obtains an IP addres...

Страница 23: ...hes in the LED indicators Figure 9 shows the location of the LED indicators on the AKD servo drive a b c Drive IP address flashed sequentially d Drive status either current operation mode or the fault...

Страница 24: ...ick the MAX icon on the desktop or select Start All Programs National Instruments Measurement Automation to open MAX 2 Expand Devices and Interfaces and then expand NI Motion Devices in the configurat...

Страница 25: ...une Main tab to tune the control loop settings and determine the relative stability of the servo axis Refer to Manually Tuning a System From Scratch in the Measurement Automation Explorer Help for Mot...

Страница 26: ...the AKD servo drive and is also available from ni com updates Complete the following steps to install AKD WorkBench 1 Insert the AKD WorkBench CD in the CD ROM drive 2 Double click Full Setup exe to...

Страница 27: ...com Getting Started with NI 7340 7350 Controllers and AKD Drives Figure 18 shows the AKD WorkBench start page Figure 18 AKD WorkBench Start Page 1 Available Drives 2 Specify Address 3 Connect to Drive...

Страница 28: ...AKD WorkBench Overview Page 4 Configure the command source and operation mode a Open the Settings page and set the Command Source to 3 Analog b Set the Operation Mode to 0 Torque Mode 1 Software Enabl...

Страница 29: ...ines rev Note The encoder resolution output value determines the equivalent resolution of an incremental encoder in pulses per revolution PPR A resolution of 2 000 lines rev is the same as 8 000 quadr...

Страница 30: ...rkBench Encoder Emulation page Figure 21 AKD WorkBench Encoder Emulation Page 6 Configure the analog input command scaling a Expand the Settings tree item and open the Motor page b Write down the moto...

Страница 31: ...page Figure 22 AKD WorkBench Motor Page c Expand the Settings tree item and open the Analog Input page d Set the Scale to the appropriate Arms V value based on the following equation Scale Motor cont...

Страница 32: ...gure 23 shows the analog input scaling setting Figure 23 AKD WorkBench Analog Input Scale Setting 7 Configure the software enable signal a Click the Parameters tree icon to list all configurable drive...

Страница 33: ...de refer to Using an EtherCAT AKD Drive in Analog Mode in the Tips and Troubleshooting section for additional settings you may need to apply 8 Activate the software enable on the drive by clicking the...

Страница 34: ...e your motion system setup by connecting and configuring additional I O such as limits as required by your application If using the UMI 7764 use the available screw terminal connections on the same ax...

Страница 35: ...ommunicate With the Drive Using Ethernet Confirm that the link LEDs on the drive and PC are both illuminated Figure 16 shows the location of the link LED on the drive UMI 7772 74 Does Not Turn On Conf...

Страница 36: ...rea Connection x where x corresponds to the number of the connection c Click Properties to open the Local Area Connection Properties dialog box d Select Internet Protocol Version 4 TCP IPv4 from the l...

Страница 37: ...ftware Manually enter the drive IP address by enabling the Specify Address checkbox on the AKD WorkBench software Start Page shown in Figure 18 To obtain the drive IP address either press the B1 butto...

Страница 38: ...GITAL OUT2 DIGITAL OUT2 DIGITAL OUT1 DIGITAL IN6 NSTOP AGND DGND DGND Fault Feedback Thermal Control Included Reference Safety Instructions and Use As Directed Br RB DC L1 L2 L3 PE 24V STO GND RB DC B...

Страница 39: ...an Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your produ...

Страница 40: ...ted States and other countries Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technolog...

Отзывы: