Chapter 2
Installation and Configuration
PC/104-GPIB for Windows 95
2-16
©
National Instruments Corporation
2. Remove the jumper and place it across only one of the jumper pins,
as shown in Figure 2-13.
Figure 2-13. PC/104-GPIB Ground Configuration Jumper Settings
3. Record the jumper setting on the
Hardware and Software
Configuration Form
in Appendix D,
Customer Communication
.
Now that you have properly configured the hardware, proceed to the
section for installation instructions.
Install the PC/104-GPIB
The PC/104-GPIB is available in two versions: stackthrough 16-bit and
stackthrough 8-bit. 16-bit modules have two PC/104 connectors and
8-bit modules have one PC/104 connector. Verify that you have the
correct version for your system.
Perform the following steps to install the PC/104-GPIB. In this section,
the term parent module generically refers to either the parent system or
the adjacent PC/104 module you stack the PC/104-GPIB onto.
1. Shut down Windows 95 and turn off your computer. Keep the
computer plugged in so that it remains grounded while you install
the PC/104-GPIB.
2. Mount the provided standoffs to the parent module before installing
the PC/104-GPIB. You might need to install the provided hex nuts
on the bottom side of the parent module to secure the standoffs in
place. Notice that the parent module might have only two mounting
holes for the standoffs instead of four; in this case, you need only
two standoffs.
a. Logic Ground Connected to Shield Ground (Default)
b. Logic Ground Disconnected from Shield Ground
W5