National Instruments Corporation
25
nuDrive Accessory User Guide
Note
If you set R
CR
equal to R
CL
, then the current reduction will be 50% (I
red
will be equal
to one-half of I
peak
).
Table 4.
Output Current versus R
CL
Value
Output Current (per Phase)
R
CL
Value (5%, 1/4 W)
RMS
Peak
0.26 A
0.36 A
180
Ω
(minimum value)
0.31 A
0.44 A
220
Ω
0.38 A
0.54 A
270
Ω
0.47 A
0.66 A
330
Ω
0.55 A
0.78 A
390
Ω
0.65 A
0.95 A
470
Ω
0.8 A
1.1 A
560
Ω
1.0 A
1.4 A
680
Ω
(factory default)
1.2 A
1.6 A
820
Ω
1.4 A
2.0 A
1.0 k
Ω
1.7 A
2.4 A
1.2 k
Ω
2.1 A
3.0 A
1.5 k
Ω
2.5 A
3.6 A
1.8 k
Ω
2.8 A
4.0 A
2.0 k
Ω
(maximum value)