Appendix B
Troubleshooting
©
National Instruments Corporation
B-7
NI 17xx Smart Camera User Manual
•
You configured the device in MAX or Vision Builder AI to expect a
trigger. Refer to the
, for information about configuring an external trigger.
LED Error Indications
STATUS LED Error Conditions
The NI Smart Camera indicates specific error conditions by flashing the
STATUS
LED a specific number of times. Refer to the
section of Chapter 6,
, for the STATUS
LED
flashing sequences and the corresponding error condition.
POWER LED is Not Lit When the NI Smart Camera is Powered On
If the power supply is properly connected to the smart camera, but the
POWER
LED does not light up, check that the power supply is 24 V
+20%/–15% and within the specifications outlined in Appendix A,
. Verify that the power supply can supply enough current for
the smart camera model in use. Using a power supply that is not within
these specifications might result in an unresponsive or unstable system and
could damage the smart camera.
Caution
The 24 V external lighting strobe is an unregulated output dependent on the range
of the power supply provided to the smart camera. If the power provided to the smart
camera is +20%/–15% with +5% AC ripple, the output could be as high as 30 V. If the
provided power exceeds the input voltage specifications of the third-party lighting
controller, do
not
connect the 24 V lighting strobe output to the controller to prevent
damage to the controller. Use a power supply with tolerances that meet the requirements
of the controller, or use the 5 V external lighting strobe.