![National Instruments NI Vision CVS-1450 Series Скачать руководство пользователя страница 39](http://html2.mh-extra.com/html/national-instruments/ni-vision-cvs-1450-series/ni-vision-cvs-1450-series_user-manual_3378143039.webp)
Chapter 3
LEDs, DIP Switches, and Connectors
©
National Instruments Corporation
3-7
NI CVS-1450 Series User Manual
Figure 3-4 shows the power connector on the CVS-1450 device. Table 3-2
lists and describes each terminal on the power connector.
Figure 3-4.
Power Connector
Earth Ground Connection
Some system setups may require using the grounding lug on the CVS-1450
device to connect the chassis to earth ground. Connecting the grounding
lug, shown in Figure 3-5, to earth ground connects the common-mode
signal of the main power to earth ground through the CVS-1450 device
chassis.
Note
An earth ground connection does
not
connect Ciso to earth ground.
Table 3-2.
Power Connector Terminals
Terminal
Description
V
Main power (24 VDC ±10%)
C
Common-mode signal
Viso
Isolated power (5 to 30 VDC)
Ciso
Isolated common-mode signal
V
iso
(5-30 VDC)
C
C
iso
POWER
V
(24 VDC ±10%)
Viso
(5-30 VDC)
C
V
(24 VDC ±10%)
Ciso
POWER