NI FlexRIO FPGA Module Installation Guide

Environmental Management

National Instruments is committed to designing and manufacturing products in an 
environmentally responsible manner. NI recognizes that eliminating certain hazardous 
substances from our products is beneficial not only to the environment but also to NI customers.

For additional environmental information, refer to the 

NI and the Environment

 Web page at 

ni.com/environment

. This page contains the environmental regulations and directives with 

which NI complies, as well as other environmental information not included in this document.

Waste Electrical and Electronic Equipment (WEEE)

EU Customers

At the end of the product life cycle, all products 

must

 be sent to a 

WEEE recycling center. For more information about WEEE recycling centers, 
National Instruments WEEE initiatives, and compliance with WEEE Directive 
2002/96/EC on Waste and Electronic Equipment, 
visit

ni.com/environment/weee

.

Where to Go for Support

The National Instruments Web site is your complete resource for technical support. At 

ni.com/support

 you have access to everything from troubleshooting and application 

development self-help resources to email and phone assistance from NI Application Engineers.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway, 
Austin, Texas, 78759-3504. National Instruments also has offices located around the world to 
help address your support needs. For telephone support in the United States, create your service 
request at 

ni.com/support

 and follow the calling instructions or dial 512 795 8248. For 

telephone support outside the United States, visit the Worldwide Offices section of 

ni.com/

niglobal

 to access the branch office Web sites, which provide up-to-date contact information, 

support phone numbers, email addresses, and current events.

⬉ᄤֵᙃѻક∵ᶧ᥻ࠊㅵ⧚ࡲ⊩ ˄Ё೑

RoHS

˅

Ё೑ᅶ᠋

National Instruments

ヺড়Ё೑⬉ᄤֵᙃѻકЁ䰤ࠊՓ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ

 

(RoHS)

DŽ݇Ѣ

National Instruments

Ё೑

RoHS

ড়㾘ᗻֵᙃˈ䇋ⱏᔩ

ni.com/

environment/rohs_china

DŽ

(For information about China RoHS compliance, 

go to 

ni.com/environment/rohs_china

.)

Содержание NI PXIe-7961R

Страница 1: ...PXIe 7961R ...

Страница 2: ...NI PXIe 7961R Manual Get Pricing Availability at ApexWaves com Call Today 1 800 915 6216 Email sales apexwaves com https www apexwaves com modular systems national instruments r series PXIe 7961R ...

Страница 3: ...I FlexRIO FPGA Module Signals 8 Specifications 10 Where to Go for Support 15 How to Use Your NI FlexRIO Documentation Set Refer to the Figure 1 and Table 1 for information about how to use your NI FlexRIO documentation set Figure 1 How to Use Your NI FlexRIO Documentation Set LabVIEW FPGA Module Help NI FlexRIO Help LabVIEW Examples INSTALL Hardware and Software CONNECT Signals and Learn About You...

Страница 4: ... Start Menu Contains installation instructions for your NI FlexRIO system and specifications for your FPGA module NI FlexRIO Adapter Module User Guide and Specifications Available from the Start Menu Contains signal information examples and specifications for your adapter module LabVIEW FPGA Module Help Embedded in LabVIEW Help Contains information about the basic functionality of LabVIEW FPGA Mod...

Страница 5: ...ecent version of NI FlexRIO Adapter Module Support is available at ni com Visit ni com info and enter famsoftware as the Info Code to download the latest version of NI FlexRIO Adapter Module Support You do not need this software if you are not using an adapter module Optional LabVIEW Real Time Module 1 The NI 1483 adapter module requires the NI IMAQ instrument driver instead of NI FlexRIO Adapter ...

Страница 6: ...e following order 1 LabVIEW Refer to the LabVIEW Release Notes for installation instructions for LabVIEW and system requirements for the LabVIEW software Refer to the LabVIEW Upgrade Notes for additional information about upgrading to the most recent version of LabVIEW for Windows Documentation for LabVIEW is available by selecting Start All Programs National Instruments LabVIEW LabVIEW Manuals 2 ...

Страница 7: ...ing the hardware For software installation information refer to Step 1 Install the Application Software and Driver Unpacking The NI FlexRIO FPGA module and the NI FlexRIO adapter module are shipped in antistatic packages to prevent electrostatic discharge from damaging device components To prevent such damage when handling the device take the following precautions Ground yourself using a grounding...

Страница 8: ...ure the chassis 2 Identify a supported PXI PXI Express slot in the chassis Figure 4 shows the symbols that indicate the slot types in a PXI PXI Express chassis Figure 4 Symbols for PXI Express PXI Express Hybrid PXI Slots If you are using a PXI Express chassis you can place PXI devices in the PXI slots If a PXI device is hybrid slot compatible you can use the PXI Express Hybrid slots PXI Express d...

Страница 9: ...g screws 6 Plug in and power on the PXI PXI Express chassis Confirming That the Device Is Recognized in Measurement Automation Explorer MAX To confirm that your device is recognized complete the following additional steps 1 Select Start All Programs National Instruments Measurement Automation 2 Expand Devices and Interfaces 3 Verify that the device appears under Devices and Interfaces RIO Devices ...

Страница 10: ...g the NI FlexRIO Adapter Module 2 Tighten the captive screws on the NI FlexRIO adapter module to secure it to the NI FlexRIO FPGA module 3 Launch LabVIEW to begin configuring your NI FlexRIO system Note MAX only recognizes which FPGA modules are in the chassis Your adapter module will not appear in MAX NI FlexRIO FPGA Module Signals Figure 8 shows the available signals on the NI FlexRIO FPGA modul...

Страница 11: ...IO_26_CC GPIO_26_n_CC GND GPIO_27 GPIO_27_n GND GPIO_28 GPIO_28_n GND GPIO_29 GPIO_29_n GND GND PCB Secondary Side Bank 0 PCB Primary Side GND GND GClk_SE GND GPIO_14 GPIO_14_n GND GPIO_15 GPIO_15_n GND GPIO_49 GPIO_49_n GND GPIO_50 GPIO_50_n GND GPIO_51 GPIO_51_n GND GPIO_52 GPIO_52_n GND GPIO_53 GPIO_53_n GND GPIO_54 GPIO_54_n GND GPIO_55 GPIO_55_n GND GPIO_56_CC GPIO_56_n_CC GND GPIO_57_CC GPIO...

Страница 12: ...MHz Timebase reference sources NI PXI 795xR PXI 10 MHz PXI_CLK10 NI PXIe 796xR PXI Express 100 MHz PXIe_CLK100 Device FPGA LUTs Flip Flops DSP48 Slices 25 18 Multiplier Embedded Block RAM kbits NI PXI 7951R Virtex 5 LX30 19 200 32 1 152 NI PXI 7952R Virtex 5 LX50 28 800 48 1 728 NI PXI 7953R Virtex 5 LX85 51 840 48 3 456 NI PXI 7954R Virtex 5 LX110 69 120 64 4 608 NI PXIe 7961R Virtex 5 SX50T 32 6...

Страница 13: ...ank 1 Bank 3 34 single ended per bank Compatibility Configured through the FPGA and based on the attached adapter module 1 2 V 1 5 V 1 8 V 2 5 V 3 3 V I O standards refer to www xilinx com Protection Refer to www xilinx com Current Refer to www xilinx com Maximum I O data rates Single ended 400 Mb s for LVDCI25 Differential 1 Gb s for LVDS Global clock inputs 1 LVTTL 1 LVDS Connection resources NI...

Страница 14: ...XI Express or PXI Express hybrid slots Maximum Power Requirements2 NI PXI 795xR 5 VDC 5 2 A 3 3 VDC 5 2 A 12 V 0 5 A 12 V 0 A NI PXIe 796xR 3 3 VDC 5 3 A 12 V 2 A Physical Dimensions not including connectors NI PXI 795xR 18 8 cm 12 9 cm 7 4 in 5 1 in NI PXIe 796xR 16 1 cm 10 8 cm 6 3 in 4 3 in Weight NI PXI 795xR 190 g 6 7 oz NI PXIe 796xR 213 g 7 5 oz I O connector High density card edge 1 The NI...

Страница 15: ...nment Ambient temperature range 20 C to 70 C tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Relative humidity range 5 to 95 noncondensing tested in accordance with IEC 60068 2 56 Note Clean the device with a soft non metallic brush Make sure that the device is completely dry and free from contaminants before returning it to service Shock and Vibration Operational shock 30 g peak half si...

Страница 16: ...missions Note For the standards applied to assess the EMC of this product refer to the Online Product Certification section Note EMC compliance evaluated with a wrapback adapter module and general purpose I O GPIO signals configured to LVTTL I O standard slew rate set to slow and drive strength set to 6 mA EMC compliance of other I O standards faster slew rates and greater drive strength is not gu...

Страница 17: ...uipment visit ni com environment weee Where to Go for Support The National Instruments Web site is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Application Engineers National Instruments corporate headquarters is located at 11500 North Mopac Exp...

Страница 18: ... product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patents Notice at ni com patents Refer to the Export Compliance Information at ni com legal export complian...