background image

Legal Information

Limited Warranty

This document is provided ‘as is’ and is subject to being changed, without notice, in future editions. For the latest version, 

refer to 

ni.com/manuals

. NI reviews this document carefully for technical accuracy; however, NI MAKES NO EXPRESS 

OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND 

SHALL NOT BE LIABLE FOR ANY ERRORS.
NI warrants that its hardware products will be free of defects in materials and workmanship that cause the product to fail to 

substantially conform to the applicable NI published specifications for one (1) year from the date of invoice.
For a period of ninety (90) days from the date of invoice, NI warrants that (i) its software products will perform substantially 

in accordance with the applicable documentation provided with the software and (ii) the software media will be free from 

defects in materials and workmanship.
If NI receives notice of a defect or non-conformance during the applicable warranty period, NI will, in its discretion: (i) repair 

or replace the affected product, or (ii) refund the fees paid for the affected product. Repaired or replaced Hardware will be 

warranted for the remainder of the original warranty period or ninety (90) days, whichever is longer. If NI elects to repair or 

replace the product, NI may use new or refurbished parts or products that are equivalent to new in performance and reliability 

and are at least functionally equivalent to the original part or product.
You must obtain an RMA number from NI before returning any product to NI. NI reserves the right to charge a fee for 

examining and testing Hardware not covered by the Limited Warranty.
This Limited Warranty does not apply if the defect of the product resulted from improper or inadequate maintenance, 

installation, repair, or calibration (performed by a party other than NI); unauthorized modification; improper environment; 

use of an improper hardware or software key; improper use or operation outside of the specification for the product; improper 

voltages; accident, abuse, or neglect; or a hazard such as lightning, flood, or other act of nature.
THE REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND THE CUSTOMER’S SOLE REMEDIES, AND SHALL 

APPLY EVEN IF SUCH REMEDIES FAIL OF THEIR ESSENTIAL PURPOSE.
EXCEPT AS EXPRESSLY SET FORTH HEREIN, PRODUCTS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF 

ANY KIND AND NI DISCLAIMS ALL WARRANTIES, EXPRESSED OR IMPLIED, WITH RESPECT TO THE 

PRODUCTS, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A 

PARTICULAR PURPOSE, TITLE OR NON-INFRINGEMENT, AND ANY WARRANTIES THAT MAY ARISE FROM 

USAGE OF TRADE OR COURSE OF DEALING. NI DOES NOT WARRANT, GUARANTEE, OR MAKE ANY 

REPRESENTATIONS REGARDING THE USE OF OR THE RESULTS OF THE USE OF THE PRODUCTS IN TERMS 

OF CORRECTNESS, ACCURACY, RELIABILITY, OR OTHERWISE. NI DOES NOT WARRANT THAT THE 

OPERATION OF THE PRODUCTS WILL BE UNINTERRUPTED OR ERROR FREE.
In the event that you and NI have a separate signed written agreement with warranty terms covering the products, then the 

warranty terms in the separate agreement shall control.

Copyright

Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, 

including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the 

prior written consent of National Instruments Corporation.
National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected 

by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials 

belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the 

terms of any applicable license or other legal restriction.

End-User License Agreements and Third-Party Legal Notices

You can find end-user license agreements (EULAs) and third-party legal notices in the following locations:

Notices are located in the 

<National Instruments>\_Legal Information

 and 

<National Instruments>

 

directories.

EULAs are located in the 

<National Instruments>\Shared\MDF\Legal\license

 directory.

Review 

<National Instruments>\_Legal Information.txt

 for information on including legal information in 

installers built with NI products.

U.S. Government Restricted Rights

If you are an agency, department, or other entity of the United States Government (“Government”), the use, duplication, 

reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the 

Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal 

Acquisition Regulation Supplement Section 252.227-7014 and 252.227-7015 for military agencies.

Trademarks

Refer to the 

NI Trademarks and Logo Guidelines

 at 

ni.com/trademarks

 for more information on National Instruments 

trademarks.
ARM, Keil, and µVision are trademarks or registered of ARM Ltd or its subsidiaries.
LEGO, the LEGO logo, WEDO, and MINDSTORMS are trademarks of the LEGO Group.
TETRIX by Pitsco is a trademark of Pitsco, Inc.
FIELDBUS FOUNDATION

 and FOUNDATION

 are trademarks of the Fieldbus Foundation.

Содержание NI PXIe-4300

Страница 1: ...SC Express NI PXIe 4300 User Manual 8 Ch 250 kS s 300 V Ch Ch Isolated Analog Input Module NI PXIe 4300 User Manual July 2015 373024B 01 ...

Страница 2: ...s email addresses and current events National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin Texas 78759 3504 USA Tel 512 683 0100 For further support information refer to the NI Services appendix To comment on National Instruments documentation refer to the National Instruments website at ni com info and enter the Info Code feedback 2010 2015 National Instruments All right...

Страница 3: ...ESS FOR A PARTICULAR PURPOSE TITLE OR NON INFRINGEMENT AND ANY WARRANTIES THAT MAY ARISE FROM USAGE OF TRADE OR COURSE OF DEALING NI DOES NOT WARRANT GUARANTEE OR MAKE ANY REPRESENTATIONS REGARDING THE USE OF OR THE RESULTS OF THE USE OF THE PRODUCTS IN TERMS OF CORRECTNESS ACCURACY RELIABILITY OR OTHERWISE NI DOES NOT WARRANT THAT THE OPERATION OF THE PRODUCTS WILL BE UNINTERRUPTED OR ERROR FREE ...

Страница 4: ...eir respective companies Patents For patents covering National Instruments products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents Export Compliance Information Refer to the Export Compliance Information at ni com legal export compliance for the National Instruments global tra...

Страница 5: ...are Timed Acquisitions 2 7 Hardware Timed Acquisitions 2 7 Analog Input Filter 2 8 Gain 2 8 Analog Input Timing Signals 2 9 Aggregate versus Single Channel Sample Rates 2 10 AI Sample Clock Signal 2 11 AI Sample Clock Timebase Signal 2 12 AI Start Trigger Signal 2 12 AI Reference Trigger Signal 2 14 AI Pause Trigger Signal 2 15 Getting Started with AI Applications in Software 2 16 External Referen...

Страница 6: ...2 Figure 2 7 Retriggerable Analog Input 2 13 Figure 2 8 Reference Trigger Final Buffer 2 14 Figure 2 9 Halt Internal Clock and Free Running External Clock 2 15 Figure 2 10 External Clock Reference 2 17 Figure 2 11 Synchronization Operation 2 19 Figure 2 12 Analog Trigger Level 2 20 Figure 2 13 Analog Edge Triggering with Hysteresis on Rising Slope 2 21 Figure 2 14 Analog Edge Triggering with Hyste...

Страница 7: ...inal Block Specifications for step by step software and hardware installation instructions Module Specifications Refer to the NI PXIe 4300 Device Specifications document for module specifications Module Accessories and Cables Refer to the NI PXIe 4300 and TB 4300 B C User Guide and Terminal Block Specifications for information about supported accessories and cables Module Self Calibration Self cal...

Страница 8: ...aces your module 3 Initiate self calibration using one of the following methods Click Self Calibrate in the upper right corner of MAX Right click the name of the module in the MAX configuration tree and select Self Calibrate from the drop down menu Note You can also programmatically self calibrate the module with NI DAQmx as described in Device Calibration in the NI DAQmx Help or the LabVIEW Help ...

Страница 9: ...to the negative terminal of the source as shown in Figure 2 1 or to an isolated ground of the source as long as the working voltage specification of the NI PXIe 4300 is not violated For best results wire the AI and AI signals as twisted pairs and use the COM as a shield The COM connection should be made as close to the source as possible to take advantage of the differential nature of this device ...

Страница 10: ...ows the pinout of the front connector of the NI PXIe 4300 Refer to the I O Connector Signal Description section for definitions of each signal Refer to the NI PXIe 4300 and TB 4300 B C User Guide and Terminal Block Specifications for signal locations on the terminal block ...

Страница 11: ...erved 32 COM 0 AI 0 0 31 AI 0 30 29 COM 1 AI 1 1 28 AI 1 27 26 COM 2 AI 2 2 25 AI 2 24 23 COM 3 AI 3 3 22 AI 3 21 20 COM 4 AI 4 4 19 AI 4 18 17 COM 5 AI 5 5 16 AI 5 15 14 COM 6 AI 6 6 13 AI 6 12 11 COM 7 AI 7 7 10 AI 7 9 8 COM 7 COM 7 COM 7 No Channel 7 PFI 0 PFI 1 6 5 4 3 2 RSVD COM 7 RSVD 1 RSVD RSVD RSVD Column A B C 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5...

Страница 12: ...r differential analog input measurements AI 0 7 AI 0 7 COM 0 7 Input Analog Input Channels 0 to 7 AI and AI are the positive and negative inputs of differential analog input PFI 0 1 COM 7 Input Programmable Function Interface Channels 0 to 1 Each of these terminals can be individually configured as PFI terminals They can be used to supply a start reference or pause trigger or be used as an externa...

Страница 13: ...n Isolated Digital Communication PXIe Bus PWM Gain Filter Selection ADC Control Selectable Filter ADC AI CH 0 300 Vrms Isolation AI0 AI0 COM AI7 AI7 COM 96 Pin DIN AI CH 7 300 Vrms Isolation Power Channel Power M CAL MUX PGIA Selectable Filter ADC AI CH 6 AI6 AI6 COM Power Channel Power Power Channel Power Terminal Block Power Isolator Isolator Isolator 300 Vrms Isolation Isolator ...

Страница 14: ...e spread fairly evenly across the input range So for an input range of 10 V to 10 V the voltage of each code of a 16 bit ADC is Choose an input range that matches the expected input range of your signal A large input range can accommodate a large signal variation but reduces the voltage resolution Choosing a smaller input range improves the voltage resolution but may result in the input signal goi...

Страница 15: ... sample of data Hardware Timed Acquisitions With hardware timed acquisitions a digital hardware signal AI Sample Clock controls the rate of the acquisition This signal can be generated internally on your device or provided externally Hardware timed acquisitions have several advantages over software timed acquisitions The time between samples can be much shorter The timing between samples is determ...

Страница 16: ...al time control applications HWTSP operations in conjunction with the wait for next sample clock function provide tight synchronization between the software layer and the hardware layer Refer to the whitepaper NI DAQmx Hardware Timed Single Point Lateness Checking for more information To access this document go to ni com info and enter the Info Code daqhwtsp Analog Input Filter The NI PXIe 4300 ha...

Страница 17: ... AI Sample Clock until the value reaches zero and all desired samples have been acquired Figure 2 4 Typical Posttriggered DAQ Sequence An acquisition with pretrigger data allows you to view data that is acquired before the trigger of interest in addition to data acquired after the trigger Figure 2 5 shows a typical pretrigger DAQ sequence The AI Start Trigger signal ai StartTrigger can be either a...

Страница 18: ...Signal AI Pause Trigger Signal Aggregate versus Single Channel Sample Rates NI PXIe 4300 modules have one ADC per channel so the single channel maximum sample rate can be achieved on each channel The maximum single channel rate is the fastest you can acquire data on the device from a single or multiple channels and still achieve accurate results The total aggregate determines the maximum bus bandw...

Страница 19: ... for more information Using an External Source Use one of the following external signals as the source of AI Sample Clock PFI 0 1 PXI_Trig 0 7 PXI_STAR PXIe_DSTAR A B Routing AI Sample Clock Signal to an Output Terminal You can route AI Sample Clock out to any PXI_Trig 0 7 or PXIe_DSTARC terminal This pulse is always active high All PFI terminals are configured as inputs by default Other Timing Re...

Страница 20: ...AI Sample Clock Timebase as either rising or falling edge except on 100 MHz Timebase or 20 MHz Timebase AI Start Trigger Signal Use the AI Start Trigger ai StartTrigger signal to begin a measurement acquisition A measurement acquisition consists of one or more samples If you do not use triggers begin a measurement with a software command by starting a task which sends the software command that beg...

Страница 21: ...Using a Digital Source To use AI Start Trigger with a digital source specify a source and an edge The source can be any of the following signals PFI 0 1 PXI_Trig 0 7 PXI_STAR PXIe_DSTAR A B The source also can be one of several other internal signals on your DAQ device Refer to Device Routing in MAX in the NI DAQmx Help or the LabVIEW Help for more information You also can specify whether the meas...

Страница 22: ...n the buffer to make space for the next sample This data can be accessed with some limitations before the DAQ device discards it Refer to the KnowledgeBase document Can a Pretriggered Acquisition be Continuous for more information To access this KnowledgeBase go to ni com info and enter the Info Code rdcanq When the reference trigger occurs the DAQ device continues to write samples to the buffer u...

Страница 23: ...n the signal is inactive You can program the active level of the pause trigger to be high or low as shown in Figure 2 9 In the figure T represents the period and A represents the unknown time between the clock pulse and the posttrigger Figure 2 9 Halt Internal Clock and Free Running External Clock Using a Digital Source To use AI Pause Trigger specify a source and a polarity The source can be any ...

Страница 24: ... mechanisms Some of the applications also use start and reference pause triggers Note For more information about programming analog input applications and triggers in software refer to the NI DAQmx Help or the LabVIEW Help in version 8 0 or later NI PXIe 4300 modules use the NI DAQmx driver NI DAQmx includes a collection of programming examples to help you get started developing an application You...

Страница 25: ...n Figure 2 10 Figure 2 10 External Clock Reference Caution Do not disconnect an external reference clock once the modules have been synchronized or are used by a task Doing so may cause NI DAQmx to return an error Make sure that all tasks using a reference clock are stopped before disconnecting it Table 2 5 Clock Signal Sourcing Signal Description PXI_Trig 0 7 Bi Directional bus connecting each bo...

Страница 26: ...iple modules depending on your application To synchronize multiple modules to a common timebase choose one module the master to generate the timebase The master module routes its 10 MHz reference clock to one of the PXI_Trig 0 7 signals All modules including the master module receive the 10 MHz reference clock from PXI_Trig This signal becomes the external reference clock A PLL on each module gene...

Страница 27: ...ition capabilities The analog trigger signal can be used as a reference trigger only This restriction is due to the fact that the analog trigger circuit operates on digitized ADC data requiring the acquisition to be running in order for the analog trigger circuit to operate In a reference triggered acquisition you configure the device to acquire a certain number of pre trigger samples and a certai...

Страница 28: ...hen the sample rate is only twice the bandwidth of interest This jitter usually has no effect on data processing and you can decrease this jitter by sampling at a higher rate Sampling at a rate less than twice the bandwidth of interest may cause the trigger signal to not reliably be detected You can use the following analog triggering modes with the NI PXIe 4300 modules rising edge rising edge wit...

Страница 29: ... falls below 2 2 V as shown in Figure 2 13 Figure 2 13 Analog Edge Triggering with Hysteresis on Rising Slope When using hysteresis with a falling slope the trigger is armed when the signal starts above Level plus the hysteresis value and asserts when the signal crosses below Level For example if you add a hysteresis of 1 V to a level of 3 2 V the signal must start at or rise above 4 2 V to arm th...

Страница 30: ...fied around the trigger Pause Acquisition is put on hold when trigger is met level sensitive only In addition the trigger circuit provides a programmable filter to help with noisy trigger signals The filter checks that the trigger condition is met for different time intervals before triggering The filter can select from 90 ns 5 12 μs 2 56 ms or a custom defined time interval For information about ...

Страница 31: ...t connected accessories in your application Refer to the NI DAQmx Help for documentation about programmatically accessing accessory status Select Start All Programs National Instruments NI DAQmx NI DAQmx Help Accessory Power The NI PXIe 4300 provides auxiliary power for accessories connected to the module and has protection in the event of a fault condition If a fault occurs in the form of an over...

Страница 32: ...ndependently to each peripheral slot in a PXI Express chassis For more information refer to the PXI Express Specification at www pxisa org PXI_CLK10 PXI_CLK10 is a common low skew 10 MHz reference clock for synchronization of multiple modules in a PXI measurement or control system The PXI backplane is responsible for generating PXI_CLK10 independently to each peripheral slot in a PXI chassis Note ...

Страница 33: ... each PFI PXI_Trig PXIe_DSTAR or PXI_STAR signal PXIe_DSTAR A C PXI Express devices can provide high quality and high frequency point to point connections between each slot and a system timing slot These connections come in the form of three low voltage differential star triggers that create point to point high frequency connections between a PXI Express system timing module and a peripheral devic...

Страница 34: ...MA the fastest available data transfer method NI uses DMA hardware and software technology to achieve high throughput rates and increase system utilization DMA is the default method of data transfer for PCI Express and PXI Express devices Programmed I O Programmed I O is a data transfer mechanism where the user s program is responsible for transferring data Each read or write call in the program i...

Страница 35: ...s you identify your systems accuracy and reliability requirements and provides warranty sparing and calibration services to help you maintain accuracy and minimize downtime over the life of your system Visit ni com services for more information Warranty and Repair All NI hardware features a one year standard warranty that is extendable up to five years NI offers repair services performed in a time...

Страница 36: ...ations Engineers make sure every question submitted online receives an answer Software Support Service Membership The Standard Service Program SSP is a renewable one year subscription included with almost every NI software product including NI Developer Suite This program entitles members to direct access to NI Applications Engineers through phone and email for one to one technical support as well...

Отзывы: