 National Instruments Corporation

5

NI PXIe-1082 Power Supply Shuttle User Guide

Configuration

The fan-speed selector switch is on the rear panel of the power supply 
shuttle. Refer to Figure 1 to locate the fan-speed selector. Select HIGH for 
maximum cooling performance (recommended) or AUTO for quieter 
operation. When set to AUTO, air-intake temperature determines the fan 
speed.

Connecting Safety Ground

Caution

The power supply shuttle is designed with a three-position NEMA 5-15 

(IEC 60320) jack that connects the ground line to the chassis ground. To minimize 
shock hazard, make sure the electrical power outlet you use to power the chassis has 
an appropriate earth safety ground.

If your power outlet does not have an appropriate ground connection, you 
must connect the premise safety ground to the chassis grounding screw. 
Refer to Figure 1 to locate the chassis grounding screw. To connect the 
safety ground, complete the following steps:

1.

Connect a 16 AWG (1.3 mm) wire to the chassis grounding screw 
using a grounding lug. The wire must have green insulation with a 
yellow stripe or must be noninsulated (bare).

2.

Attach the opposite end of the wire to permanent earth ground using 
toothed washers or a toothed lug.

Specifications

AC Input

Input voltage range................................. 100 to 240 VAC

Operating voltage range

1

........................ 90 to 264 VAC

Input frequency ...................................... 50/60 Hz

Operating frequency range

1

................... 47 to 63 Hz

Input current rating................................. 8–4 A

Over-current protection.......................... 10 A circuit breaker

1   

The operating range is guaranteed by design.

Содержание NI PXIe-1082

Страница 1: ...er supply shuttle This power supply shuttle includes the chassis power supply cooling fans and fan control circuitry Key features of the power supply shuttle include Universal AC input with automatic voltage and frequency ranging Over current protection via push reset circuit breaker Remote power monitoring and inhibit via a rear panel connector Temperature sensing module that can adjust fan speed...

Страница 2: ...he shuttle for any possible damage debris or detached components If damage appears to have been caused during shipment file a claim with the carrier Retain the packing material for possible inspection and or reshipment What You Need to Get Started NI PXIe 1082 chassis the unit being repaired NI PXIe 1082 power supply shuttle Read Me First Safety and Electromagnetic Compatibility NI PXIe 1082 User ...

Страница 3: ...Supply Shuttle 2 Push Reset Circuit Breaker 3 Universal AC Input 4 Chassis Ground Screw 5 10 MHz REF OUT BNC 6 10 MHz REF IN BNC 7 Remote Inhibit and Voltage Monitoring Connector 8 Air Filter Retainer 9 Air Filter Retainer Screw 10 Power Supply Shuttle ID Label 11 Fan Speed Selector Switch 12 Inhibit Mode Selector Switch 13 Power Supply Shuttle Handle 2x 14 Power Supply Shuttle Mounting Screws 8x ...

Страница 4: ...PXIe 1082 User Manual contains all of the most up to date chassis service procedures including removal and replacement of power supply shuttles The chassis includes a hardcopy of the NI PXIe 1082 User Manual additionally you can download a softcopy from ni com support Removal Before attempting to replace the power supply shuttle verify that there is adequate clearance behind the chassis With the c...

Страница 5: ...an appropriate earth safety ground If your power outlet does not have an appropriate ground connection you must connect the premise safety ground to the chassis grounding screw Refer to Figure 1 to locate the chassis grounding screw To connect the safety ground complete the following steps 1 Connect a 16 AWG 1 3 mm wire to the chassis grounding screw using a grounding lug The wire must have green ...

Страница 6: ...ide DC power to the CompactPCI PXI Express backplane You also can use the rear panel D SUB 9 pin connector and power mode switch to control the internal chassis power supply DC Output DC current capacity IMP Notes Maximum total power is 507 W The maximum power dissipated in the system slot should not exceed 140 W The maximum power dissipated in a peripheral slot should not exceed 38 W Voltage Maxi...

Страница 7: ...ove nominal output voltage Power supply shuttle MTTR Replacement in under 5 minutes Slot 5 V V I O 3 3 V 12 V 12 V 5 VAUX System Controller Slot 9 A 0 A 9 A 11 A 0 A 1 A System Timing Slot 0 A 0 A 3 A 2 A 0 A 1 A Hybrid Peripheral Slot with PXI 1 Peripheral 6 A 5 A 6 A 1 A 1 A 0 A Hybrid Peripheral Slot with PXI 5 Peripheral 0 A 0 A 3 A 2 A 0 A 1 A PXI 1 Peripheral Slot 6 A 11 A 6 A 1 A 1 A 0 A Vo...

Страница 8: ...Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents 2009 National Instruments Corporation All rights reserved 373026A 01 N...

Отзывы: