background image

© 

National Instruments Corporation

29

NI Digital Waveform Generator/Analyzer Guide

your service request at 

ni.com/support

 and follow the calling instructions 

or dial 512 795 8248. For telephone support outside the United States, 
contact your local branch office: 

Australia 1800 300 800, Austria 43 0 662 45 79 90 0, 
Belgium 32 0 2 757 00 20, Brazil 55 11 3262 3599, 
Canada (Calgary) 403 274 9391, Canada (Ottawa) 613 233 5949, 
Canada (Québec) 450 510 3055, Canada (Toronto) 905 785 0085, 
Canada (Vancouver) 604 685 7530, China 86 21 6555 7838, 
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, 
Finland 385 0 9 725 725 11, France 33 0 1 48 14 24 24, 
Germany 49 0 89 741 31 30, India 91 80 51190000, Israel 972 0 3 6393737, 
Italy 39 02 413091, Japan 81 3 5472 2970, Korea 82 02 3451 3400, 
Malaysia 603 9131 0918, Mexico 01 800 010 0793, 
Netherlands 31 0 348 433 466, New Zealand 0800 553 322, 
Norway 47 0 66 90 76 60, Poland 48 22 3390150, 
Portugal 351 210 311 210, Russia 7 095 783 68 51, 
Singapore 65 6226 5886, Slovenia 386 3 425 4200, 
South Africa 27 0 11 805 8197, Spain 34 91 640 0085, 
Sweden 46 0 8 587 895 00, Switzerland 41 56 200 51 51, 
Taiwan 886 2 2528 7227, Thailand 662 992 7519, 
United Kingdom 44 0 1635 523545

Содержание NI PCI-6542

Страница 1: ...r Help at Start Programs National Instruments NI HSDIO Documentation NI Digital Waveform Generator Analyzer Help Refer to the specifications document that ships with your device for detailed specifica...

Страница 2: ...ues associated with a bit or signal name for example DIO 3 0 The symbol leads you through nested menu items and dialog box options to a final action The sequence File Page Setup Options directs you to...

Страница 3: ...responses that the computer automatically prints to the screen This font also emphasizes lines of code that are different from the other examples monospace italic Italic text in this font denotes tex...

Страница 4: ...A PXI chassis and controller or desktop computer 1 8 in flathead screwdriver Number 1 Phillips screwdriver Microsoft Internet Explorer 5 5 or later Measurement Automation Explorer MAX 3 1 or later A...

Страница 5: ...llowing precautions Ground yourself with a grounding strap or by touching a grounded object Touch the antistatic package to a metal part of your computer chassis before removing the device from the pa...

Страница 6: ...you should install the gasket Refer to step 5 Installing the Hardware for more information about the gasket 4 Installing the Software This section describes the software installation process for the...

Страница 7: ...CD and is installed when you install the driver The NI Script Editor provides an intuitive interface to help you develop linking and looping pattern generation operations NI Script Editor Help contai...

Страница 8: ...speed to low or turn the fan off 3 Position the chassis so that you allow plenty of space between the chassis fan intake and exhaust vents Blocking the fans affects the air flow needed for cooling For...

Страница 9: ...ot clean the module with any solvents or liquids For more information about module cooling refer to the guidelines in the Maintain Forced Air Cooling Note to Users included with your NI digital wavefo...

Страница 10: ...recommends either leaving the slot adjacent to the fan side of the device empty or using lower profile devices in the slot adjacent to the fan side 5 Secure the device with the screw provided in the...

Страница 11: ...igure and test the digital waveform generator analyzer MAX should automatically detect the device you installed 2 Expand Devices and Interfaces If you are using an NI digital waveform generator analyz...

Страница 12: ...igned to the digital device You need this information when you program the device Using the Test Panel to Generate and Acquire Data To verify your device configuration use the device test panel in MAX...

Страница 13: ...tons are shown in the following figure Because the data channels on the NI digital waveform generator analyzer are bidirectional while the data is being continuously generated on all of the channels a...

Страница 14: ...for differential high speed digital signal transmission Using Accessories NI 654X 655X Only NI recommends using the NI CB 2162 single ended digital I O accessory to access the signals on the 68 pin DD...

Страница 15: ...tal Waveform Generator Analyzer 2 SHC68 C68 D2 Cable 3 NI CB 2162 Accessory 1 PXI Chassis with NI Digital Waveform Generator Analyzer 2 NI SMB 2163 Accessory 3 SHC68 C68 D2 Cable NI PXI 6551 50 MHz Di...

Страница 16: ...igital waveform generator analyzers This section provides information on the general wiring considerations for each type of application Both examples use the NI CB 2162 for signal termination Dynamic...

Страница 17: ...gure 7 Dynamic Acquisition Functional Diagram Note NI digital waveform generator analyzers have various input impedance settings as shown in the following table Refer to the NI Digital Waveform Genera...

Страница 18: ...The NI HSDIO examples demonstrate some of the functionality of the NI digital waveform generator analyzers that you can use or integrate into your applications For the location of example programs tha...

Страница 19: ...1 22 23 24 25 26 27 28 29 30 31 32 33 34 DIO 31 GND DIO 29 GND DIO 27 GND DIO 25 RESERVED DIO 23 GND DIO 21 GND DIO 19 GND DIO 17 GND DIO 15 GND DIO 13 GND DIO 11 GND DIO 9 GND DIO 7 PFI 1 DIO 5 GND D...

Страница 20: ...uisition 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 DIO 0 31 Data Bidirectional digital I O data channels 0 through 31 26 30 64 PFI 1 3 Control Input te...

Страница 21: ...3 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 RESERVED GND RESERVED GND RESERVED GND RESERVED RESERVED RES...

Страница 22: ...01 the NI 656X pinout is reversed at the end connector For example the signal shown on pin 1 shown in the previous figure would map to pin 73 at the end connector Table 5 NI 655X DDC Connector Pins P...

Страница 23: ...DIO 9 GND DIO 10 GND DIO 11 GND DIO 12 GND DIO 13 GND DIO 14 GND DIO 15 GND STROBE GND DDC CLK OUT LVDS GND RESERVED NC GND DDC CLK OUT LVPECL GND PFI_1 PFI_2 PFI_3 GND RESERVED NC DIO 0 DIO 1 DIO 2 D...

Страница 24: ...orted Sample clock 72 DDC CLK OUT LVPECL Control Complementary terminal for the LVPECL exported Sample clock 62 STROBE Control Positive external Sample clock source which can be used for dynamic acqui...

Страница 25: ...L or for the external Sample clock used for pattern generation and or acquisition PFI 0 Programmable Function Interface PFI 0 Control Input terminal to the device for external triggers or output termi...

Страница 26: ...s from the PXI module front panel 3 Remove the PXI module and inspect for signs of damage Do not reinstall a damaged device 4 Reinstall the PXI module using the procedure described in step 5 Installin...

Страница 27: ...ll fails the self test proceed to step 3 3 Uninstall and reinstall NI HSDIO 4 If the device still fails the self test contact NI support at ni com support I Received a Thermal Shutdown Error I receive...

Страница 28: ...e issues refer to the MXI documentation at Start Programs National Instruments MXI or visit NI Technical Support at ni com support Technical Support Resources NI Web Support The National Instruments W...

Страница 29: ...85 7530 China 86 21 6555 7838 Czech Republic 420 224 235 774 Denmark 45 45 76 26 00 Finland 385 0 9 725 725 11 France 33 0 1 48 14 24 24 Germany 49 0 89 741 31 30 India 91 80 51190000 Israel 972 0 3 6...

Страница 30: ......

Страница 31: ......

Страница 32: ...bout National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products ref...

Отзывы: