Chapter 10
Electronic Gearing and Camming
10-18
ni.com
Figure 10-17.
Camming Profile Starts when First Material Passes
Figure 10-18 shows the camming profile used for the application portrayed
in Figure 10-16 and Figure 10-17.
Figure 10-18.
Camming Profiles with and without Master Offset
Camming starts
here at position 50
Master cycle begins
at position 50.
0
500
1000
1500
2000
2500
0
2000
4000
6000
8000
10000
Master
S
lave
Without Master Offset
With Master Offset
Master Offset