Configuring the Device in NI Vision Builder AI

Complete the following steps to configure the device in Vision Builder AI.
1. Launch Vision Builder AI by navigating to 

Start»All Programs»National Instruments»

Vision Builder AI

.

2. Select the NI CVS-1458RT from the list of available targets.
3. Select the 

Configure Target

 icon.

4. Complete the configuration wizard. At step 3, select 

Update Target Software

 to install 

Vision Builder AI on the device.

Configuring the Device in NI MAX

Complete the following steps to configure the device in MAX.
1. Launch MAX by navigating to 

Start»All Programs»National Instruments»NI MAX 

or 

by double-clicking the NI MAX desktop icon.

2. In the Configuration pane, expand 

Remote Systems

 to see a list of devices on the same 

subnet.

3. Locate and expand the NI CVS-1458RT. The default name for each device is 

NI-CVS-1458RT-XXXXXXXX

, where 

XXXXXXXX

 is the eight digit serial number.

4. Right-click 

Software

 and select 

Add/Remove Software

.

5. Select 

NI-IMAQdx

,

 NI Vision-RIO

,

 NI Vision RT

,

 LabVIEW Real-Time

, and 

NI-RIO

Some features will automatically select required dependencies.

6. Complete the installation wizard.

Acquiring an Image

To ensure the NI CVS-1458RT is functioning properly, acquire a test image.

Acquiring an Image in Vision Builder AI

Complete the following steps to acquire an image in Vision Builder AI.
1. Launch Vision Builder AI.
2. Select the NI CVS-1458RT from the list of available targets.
3. In the Configure Inspection section, select 

New Inspection from Template

.

4. Select 

Acquire Image Template

 from the Compact Vision System tree.

5. Click the 

Run Inspection Once

 icon to acquire an image.

Acquiring an Image in MAX

Complete the following steps to acquire an image in MAX.
1. Launch MAX.
2. In the Configuration Pane, expand 

Remote Systems 

to see a list of devices on the same 

subnet.

Содержание NI CVS-1458RT

Страница 1: ...5 Installing the Vision Development Module 6 Configuring the Hardware 7 Connecting the System Power Supply 8 Connecting the Isolated Outputs Power Supply and PoE Power Supply 9 Connecting GigE Vision...

Страница 2: ...1 000 Mbps CAT 5 cables are likely to cause bit errors resulting in degraded network performance Development computer running Microsoft Windows Refer to the driver or application development software...

Страница 3: ...tion Software August 2014 One of the following options for developing machine vision applications NI Vision Builder for Automated Inspection Vision Builder AI 2014 or later LabVIEW 2014 or later LabVI...

Страница 4: ...ation instructions All covers and filler panels must be installed while operating the device This is a Pollution Degree 2 device Do not operate the device in an explosive atmosphere or where flammable...

Страница 5: ...y National Instruments could void your authority to operate it under your local regulatory rules Caution To ensure the specified EMC performance operate this product only with shielded cables and acce...

Страница 6: ...ms National Instruments LabVIEW 4 NI Vision Development Module Refer to the NI Vision Development Module Readme on the NI Vision Development Module installation media for system requirements and insta...

Страница 7: ...in or unplugging any connector Ground the unit to minimize the possibility of static electricity damage Complete the following sections to wire power to the NI CVS 1458RT connect cameras and connect t...

Страница 8: ...egative and positive leads of the power source approximately 50 to 75 mm 2 to 3 in from the end of the power input wires as shown in Figure 3 Figure 3 Installing a Ferrite on the Power Leads 1 VGA Con...

Страница 9: ...tor plug and tighten the terminal screw to 0 2 to 0 25 N m 1 8 to 2 2 lb in of torque 6 Install the power connector plug into the SYSTEM power receptacle on the NI CVS 1458RT chassis and tighten the c...

Страница 10: ...torque 5 Connect the negative lead of the isolated outputs power source to the CISO terminal of the power connector plug and tighten the terminal screw to 0 2 to 0 25 N m 1 8 to 2 2 lb in of torque 6...

Страница 11: ...to the development computer 1 Verify the that the development computer is powered on and connected to the network 2 Connect one end of an Ethernet cable to the network port on the device 3 Connect the...

Страница 12: ...CVS 1458RT The default name for each device is NI CVS 1458RT XXXXXXXX where XXXXXXXX is the eight digit serial number 4 Right click Software and select Add Remove Software 5 Select NI IMAQdx NI Vision...

Страница 13: ...ate and expand the NI CVS 1458RT The default name for each device is NI CVS 1458RT XXXXXXXX where XXXXXXXX is the eight digit serial number 4 Expand NI CVS 1458RT XXXXXXXX Devices and Interfaces 5 Sel...

Страница 14: ...TTL 1 Bidirectional TTL I O 5 GND Digital ground reference for TTL and differential I O 6 TTL 2 Bidirectional TTL I O 7 TTL 3 Bidirectional TTL I O 8 GND Digital ground reference for TTL and differen...

Страница 15: ...ral purpose isolated input 33 CISO Common ground reference for isolated inputs and outputs 34 Iso In 2 General purpose isolated input 35 Iso In 3 General purpose isolated input 36 CISO Common ground r...

Страница 16: ...n Builder AI inspections are installed to the Vision Builder AI Examples directory where Vision Builder AI is the location Vision Builder AI is installed Additional Resources for LabVIEW Users Documen...

Страница 17: ...ncil of the European Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the...

Страница 18: ...s You can find information about end user license agreements EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal expor...

Отзывы: