Safety Guidelines

Caution

Do not operate this module in a manner not specified in these operating 

instructions. Do not exceed the 60VDC rating. Product misuse can result in a hazard. 
You can compromise the safety protection built into the product if the product is 
damaged in any way. If the product is damaged, return it to National Instruments for 
repair.

Compliance and Certifications

Safety

This product meets the requirements of the following standards of safety for electrical equipment 
for measurement, control, and laboratory use:

IEC 61010-1, EN 61010-1

UL 61010-1, CSA 61010-1

Electromagnetic Compatibility

This product meets the requirements of the following EMC standards for electrical equipment 
for measurement, control, and laboratory use:

EN 61326-1 (IEC 61326-1): Class A emissions; Industrial immunity

EN 55011 (CISPR 11): Group 1, Class A emissions

AS/NZS CISPR 11: Group 1, Class A emissions

FCC 47 CFR Part 15B: Class A emissions

ICES-001: Class A emissions

Caution

When operating this product, use shielded cables and accessories.

CE Compliance

This product meets the essential requirements of applicable European Directives as follows:

2006/95/EC; Low-Voltage Directive (safety)

2004/108/EC; Electromagnetic Compatibility Directive (EMC)

Environmental Management

NI is committed to designing and manufacturing products in an environmentally responsible 
manner. NI recognizes that eliminating certain hazardous substances from our products is 
beneficial to the environment and to NI customers.

For additional environmental information, refer to the 

Minimize Our Environmental Impact 

web 

page at 

ni.com/environment

. This page contains the environmental regulations and 

directives with which NI complies, as well as other environmental information not included in 
this document.

Содержание NI 9760

Страница 1: ...Hardware 2 Powering the Module 2 Platform Compatibility 3 Input Channels Used for VR Sensor Inputs 3 Input Channels Used for Hall Effect Sensor Inputs 5 Custom Configuration 6 Physical Specifications...

Страница 2: ...ut Features 6 channels software configured as VR sensor or Hall Effect sensor inputs 600 kHz lowpass filter VR sensor inputs 60 V input range Adaptive manually programmable arming thresholds Hall effe...

Страница 3: ...is properly powered You can power the NI 9760 only at the HD15 connector by plugging it into a CompactRIO or R Series Expansion Chassis Do not connect the HD15 connector to any other device If the 5V...

Страница 4: ...8 68 RDIO cable MXI Express Ethernet and EtherCAT expansion chassis Note NI Powertrain Control modules are not compatible with the National Instruments CompactDAQ chassis Note NI Powertrain Control mo...

Страница 5: ...s a positive physical tooth polarity and Figure 3 demonstrates a negative physical tooth polarity Assuming the lead polarity of a sensor remained the same one of the configurations would generate the...

Страница 6: ...s directly proportional to the speed of the trigger wheel For example if the VR amplitude at 1000 RPM is 10 V then the amplitude at 2000 RPM will be 20 V By using an oscilloscope to measure the VR amp...

Страница 7: ...tions and Characteristics External Power Input Range 5 to 30 VDC Max Reverse Polarity Protection 30 V 5 V Regulated Output Voltage Tolerance 5 V 3 Vsup 6 V Current 200 mA Short circuit Protection 400...

Страница 8: ...Class A emissions Industrial immunity EN 55011 CISPR 11 Group 1 Class A emissions AS NZS CISPR 11 Group 1 Class A emissions FCC 47 CFR Part 15B Class A emissions ICES 001 Class A emissions Caution Whe...

Страница 9: ...e data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52 227 14 DFAR 252 227 7014 and DFAR 252...

Отзывы: