34
|
ni.com | Getting Started with NI 9512 Modules and AKD Servo Drives
21. In the
eth0 (Primary)
section click
More Settings
and change
Packet Detection
to
Polling
. Leave the
Polling Interval
at 1 ms.
When you have completed these steps the
Network Settings
tab will look similar to
Figure 24.
Figure 24.
Network Settings Ta
b
22. Click
Save
.
23. Close MAX.
24. Continue with
Step 2: Create a Project in Scan Interface Mode
.
Adding the EtherCAT Master Device to the La
b
VIEW
Project
If you are using the NI 9144 chassis, complete the following steps to add the EtherCAT master
device and detect the C Series modules.
1.
In the LabVIEW
Project Explorer
window, right-click the master controller and select
New»Targets and Devices
.
2.
In the
Add Targets and Devices
dialog window shown in Figure 25, select
Existing target
or device
and expand the category EtherCAT Master Device to auto-discover the EtherCAT
port on the master controller. An EtherCAT master device and modules can be added
manually at any time.
Содержание NI 9512 C Series