using the NI 9503 in Gas Group IIC hazardous locations, you
must use the device in an NI chassis that has been evaluated as
Ex nC IIC T4, EEx nC IIC T4, Ex nA IIC T4, or Ex nL IIC T4
equipment.
Caution
You
must
make sure that transient disturbances
do not exceed 140% of the rated voltage.
Caution
The system shall be mounted in an ATEX
certified enclosure with a minimum ingress protection
rating of at least IP54 as defined in IEC/EN 60529 and
used in an environment of not more than Pollution
Degree 2.
Caution
The enclosure must have a door or cover
accessible only by the use of a tool.
Electromagnetic Compatibility Guidelines
This product was tested and complies with the regulatory
requirements and limits for electromagnetic compatibility (EMC)
as stated in the product specifications. These requirements and
limits are designed to provide reasonable protection against