![National Instruments NI 9476E Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/national-instruments/ni-9476e/ni-9476e_operating-instructions-and-specifications_3564721012.webp)
12
|
ni.com
|
NI 9476E Operating Instructions and Specifications
Continuous overvoltage
protection (
V
sup
) ................................ up to 40 V max
Reversed-voltage protection ............. None
Current limiting ................................ None
Short-circuit protection..................... Indefinitely protected when a
channel is shorted to COM or
to a voltage up to
V
sup
Trip current for one channel
With all other channels
at rated current............................ 3 A typ
With all other channels off ......... 5 A typ
V
sup
current consumption .................. 28 mA max
Maximum update rate ....................... 40
μ
s max
Propagation delay ............................. 500