background image

products, visit 

ni.com/product-certifications

, search by model number, and click the

appropriate link.

Shock and Vibration

To meet these specifications, you must panel mount the system.

Operating vibration

Random

5 g RMS, 10 Hz to 500 Hz

Sinusoidal

5 g, 10 Hz to 500 Hz

Operating shock

30 g, 11 ms half sine; 50 g, 3 ms half sine; 18 shocks at 6 orientations

Environmental

Refer to the manual for the chassis you are using for more information about

meeting these specifications.

Operating temperature (IEC 60068-2-1, IEC 60068-2-2)

-40 °C to 70 °C

Storage temperature (IEC 60068-2-1, IEC 60068-2-2)

-40 °C to 85 °C

Ingress protection

IP40

Operating humidity (IEC 60068-2-30)

10% RH to 90% RH, noncondensing

Storage humidity (IEC 60068-2-30)

5% RH to 95% RH, noncondensing

Pollution Degree

2

Maximum altitude

2,000 m

Indoor use only.

Environmental Management

NI is committed to designing and manufacturing products in an environmentally

responsible manner. NI recognizes that eliminating certain hazardous substances

from our products is beneficial to the environment and to NI customers.

For additional environmental information, refer to the Engineering a Healthy

Planet web page at 

ni.com/environment

. This page contains the environmental

ni.com

12

NI-9469 Getting Started

Содержание NI 9469

Страница 1: ...NI 9469 Getting Started 2022 07 06...

Страница 2: ...lication 7 Topologies 7 Activity LEDs 8 Sleep Mode 8 NI 9469 Specifications 9 I O Characteristics 9 Cable 10 Power Requirements 10 Physical Characteristics 10 Safety Voltages 10 Safety Compliance and...

Страница 3: ...ons and cautions in the user documentation Using the product in a manner not specified can damage the product and compromise the built in safety protection Attention Suivez toutes les instructions et...

Страница 4: ...uipment under DEMKO ATEX and is IECEx certified Each NI 9469 is marked and is suitable for use in Zone 2 hazardous locations in ambient temperatures of 40 C Ta 70 C If you are using the NI 9469 in Gas...

Страница 5: ...on reception and prevent unacceptable performance degradation install and use this product in strict accordance with the instructions in the product documentation Furthermore any changes or modificati...

Страница 6: ...to drive or receive four differential signals through the cable which are referred to as Line 0 to 3 Each port can carry either four triggers or three triggers and one clock in which Line 3 is dedica...

Страница 7: ...ogical network of NI 9469 modules Refer to the Topologies section for examples of various topological networks Based on user needs you may desire certain topologies over others due to application or t...

Страница 8: ...Daisychain Topology Figure 5 Hybrid Topology Activity LEDs The NI 9469 has four front panel LEDs labeled Trig 0 Trig 1 Trig 2 and Trig 3 Clk The LEDs blink when activity is detected on the correspond...

Страница 9: ...pecifications section for more information about power consumption and thermal dissipation Notice that when the NI 9469 is in sleep mode the clock generation settings if used must be reconfigured when...

Страница 10: ...5e in TIA EIA 568 Standard Power Requirements Power consumption from chassis Active mode 1 W maximum Sleep mode 25 W Thermal dissipation at 70 C Active mode 1 W maximum Sleep mode 25 W Physical Charac...

Страница 11: ...No 60079 0 CSA C22 2 No 60079 7 Note For safety certifications refer to the product label or the Product Certifications and Declarations section Hazardous Locations U S UL Canada C UL Europe DEMKO El...

Страница 12: ...0 C to 70 C Storage temperature IEC 60068 2 1 IEC 60068 2 2 40 C to 85 C Ingress protection IP40 Operating humidity IEC 60068 2 30 10 RH to 90 RH noncondensing Storage humidity IEC 60068 2 30 5 RH to...

Страница 13: ...China RoHS compliance go to ni com environment rohs_china NI Services Visit ni com support to find support resources including documentation downloads and troubleshooting and application development s...

Отзывы: