![National Instruments NI 9403 Скачать руководство пользователя страница 12](http://html2.mh-extra.com/html/national-instruments/ni-9403/ni-9403_operating-instructions-manual_3484753012.webp)
NI 9403 Operating Instructions and Specifications
12
ni.com
Timing
Inp
u
t
Set
u
p time
1
........................... 10 ns min
Hold time
2
............................ 60 ns min
O
u
tp
u
t
Propagation delay
3
............... 330 ns max
Channel-to-channel skew
4
... 265 ns max
1
Setup time
is the amo
u
nt of time inp
u
t signals m
u
st be stable before reading from the
mod
u
le.
2
Hold time
is the amo
u
nt of time inp
u
t signals m
u
st be stable after initiating a read
from the mod
u
le.
3
Propagation delay
is the amo
u
nt of time after writing to the mod
u
le that the o
u
tp
u
t
signals become valid.
4
Channel-to-channel skew
is the amo
u
nt of time between the first o
u
tp
u
t signal
u
pdating and the last o
u
tp
u
t signal
u