background image

NI 9375 Pinout

DI8

DI9

DI10

DI11

DI12

DI13

DI14

DI15
NC

DO COM 
DO8

DO9

DO10

DO11

DO12

DO13

DO14

DO15

DI0

DI1

DI2

DI3

DI4

DI5

DI6

DI7

DI COM

NC

DO0

DO1

DO2

DO3

DO4

DO5

DO6

DO7

Vsup

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19

20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37

DI0
DI1

DI3

DI5

DI7

DO0

DO2

DO4

DO6

DO COM

DI2

DI4

DI6

DI COM

DO1

DO3

DO5

DO7

DI9

DI8

DI10

DI12

DI14

NC

DO9

DO11

DO13

DO15

DI11

DI13

DI15

DO8

DO10

DO12

DO14

Vsup

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18

19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Signal

Description

DI

Digital input signal connection

DI COM

Common reference connection for the digital inputs

DO

Digital output signal connection

DO COM

Common reference connection for the digital outputs

NC

No connection

V

sup

Voltage supply connection

Table 1. Signal Descriptions

Sourcing-Output Connections

You can connect 2- and 3-wire sourcing-output devices to the NI 9375.

NI 9375

External

Power

Supply

+

Sourcing-Output

Device

DI COM

DI

© National Instruments

7

NI-9375 Getting Started

Содержание NI 9375

Страница 1: ...NI 9375 Getting Started 2022 07 06...

Страница 2: ...ines 5 Special Conditions for Marine Applications 6 Preparing the Environment 6 NI 9375 Pinout 6 Sourcing Output Connections 7 Connecting Digital Devices 8 Protecting the Digital Outputs from Flyback...

Страница 3: ...ch component in the system to determine the safety and EMC ratings for the entire system Safety Guidelines Caution Observe all instructions and cautions in the user documentation Using the product in...

Страница 4: ...are installing the NI 9375 in a potentially explosive environment Not following these guidelines may result in serious injury or death Caution Do not disconnect I O side wires or connectors unless po...

Страница 5: ...than Pollution Degree 2 as defined in IEC EN 60664 1 Caution The system shall be mounted in an ATEX IECEx certified enclosure with a minimum ingress protection rating of at least IP54 as defined in I...

Страница 6: ...arch by model number and click the appropriate link Notice In order to meet the EMC requirements for marine applications install the product in a shielded enclosure with shielded and or filtered power...

Страница 7: ...I15 DO8 DO10 DO12 DO14 Vsup 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Signal Description DI Digital input signal connection DI COM Common refer...

Страница 8: ...ower Supply Caution Do not install or remove C Series modules from your system if any external power supplies connected to the Vsup and COM pins are powered on Attention Ne pas installer ou retirer le...

Страница 9: ...r Supply DO COM Vsup Inductive Device DO Flyback Diode Connecting to a Spring Terminal Connector What to Use NI 9375 spring terminal connector 0 08 mm2 to 1 0 mm2 28 AWG to 18 AWG copper conductor wir...

Страница 10: ...that protects it from overcurrents resulting from a short circuit or faulty loads Notice Overvoltage and reverse bias voltage conditions can damage the NI 9375 Check the voltage specifications for al...

Страница 11: ...ion downloads and troubleshooting and application development self help such as tutorials and examples Visit ni com services to learn about NI service offerings such as calibration options repair and...

Отзывы: