NI 9351 Connection Guidelines
•
Make sure that devices you connect to the NI 9351 are
compatible with the module specifications.
•
You must use a two-wire ferrule to create a secure connection
when connecting two wires or stranded wires to a single
terminal.
•
Push a solid wire or ferrule directly into the terminal.
•
When inserting a stranded wire without a ferrule, first open
the terminal by pressing the push button.
•
Verify that all strands of a stranded wire are securely retained.
•
Connect one COM terminal for each DO and each DI
connection until all COM terminals are populated. It is
acceptable but not preferred to populate COM terminals with
jumpers to meet this requirement. This requirement does not
apply to the AI COM terminals.
Caution
After inserting a wire into a spring terminal,
test the connection by gently pulling on the wire to
verify that it is securely retained.
30
|
ni.com
|
NI 9351 Getting Started Guide