AI0 is the reading from Phase A

AI1 is the reading from Phase B

Where to Go Next

NI Services

Visit 

ni.com/support

 to find support resources including documentation,

downloads, and troubleshooting and application development self-help such as

tutorials and examples.
Visit 

ni.com/services

 to learn about NI service offerings such as calibration options,

repair, and replacement.
Visit 

ni.com/register

 to register your NI product. Product registration facilitates

technical support and ensures that you receive important information updates from

NI.
NI corporate headquarters is located at 11500 N Mopac Expwy, Austin, TX,

78759-3504, USA.

© National Instruments

15

NI-9244 Getting Started

© 2022 National Instruments Corporation.

Содержание NI-9244

Страница 1: ...NI 9244 Getting Started 2022 07 06...

Страница 2: ...lications 7 Preparing the Environment 7 NI 9244 Pinout 7 Connecting Phase Measurements 8 Three Phase Measurement Configurations 8 Connecting Single Phase Measurement Configurations 10 Connection Guide...

Страница 3: ...and EMC ratings for the entire system Safety Guidelines Caution Observe all instructions and cautions in the user documentation Using the product in a manner not specified can damage the product and...

Страница 4: ...er than 30 V RMS 42 4 V peak or 60 V DC in DRY LOCATIONS 16 V RMS 22 6 V peak or 35 V DC in WET LOCATIONS Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering...

Страница 5: ...NI 9244 is suitable for use in Class I Division 2 Groups A B C D T4 hazardous locations Class I Zone 2 AEx nA IIC T4 Gc and Ex nA IIC T4 Gc hazardous locations and nonhazardous locations only Follow t...

Страница 6: ...Caution The system shall only be used in an area of not more than Pollution Degree 2 as defined in IEC EN 60664 1 Caution The system shall be mounted in an ATEX IECEx certified enclosure with a minim...

Страница 7: ...om product certifications search by model number and click the appropriate link Notice In order to meet the EMC requirements for marine applications install the product in a shielded enclosure with sh...

Страница 8: ...enced single ended analog input connection Table 1 Signal Descriptions Connecting Phase Measurements The NI 9244 accepts three phase and single phase measurement configuration Three Phase Measurement...

Страница 9: ...a Measurement Configuration NI 9244 AI0 Phase A Phase B Phase C Neutral AI2 AI1 Neutral 3 Wire Delta Measurement Configuration NI 9244 AI0 Phase A Phase B Phase C AI2 AI1 Corner Grounded 2 Wire Delta...

Страница 10: ...Phase Measurement Configurations NI recommends the following single phase connection types 3 Wire Measurement Split Phase Configuration NI 9244 AI0 Neutral AI1 2 Wire Measurement NI 9244 AI0 Neutral C...

Страница 11: ...ibration NI recommends that you follow these guidelines to protect connections to the NI 9244 Use ferrules to terminate wires to the detachable connector Use the NI 9969 connector backshell kit Wiring...

Страница 12: ...ure the smallest strain relief piece and the backshell in place using captive screws Installing the NI 9969 Using 16 AWG Wire What to Use NI 9969 backshell 16 AWG wire Small and large strain relief pi...

Страница 13: ...strain relief piece underneath the wires 2 Secure the strain relief pieces and the backshell in place using captive screws Installing the NI 9969 Using 18 AWG to 24 AWG Wire What to Use NI 9969 backsh...

Страница 14: ...wing equation for an example of converting L N measurements to L Earth Line to Earth AIx Neutral where AIx is the analog input channel reading Neutral is the Neutral channel reading Converting L N Mea...

Страница 15: ...xamples Visit ni com services to learn about NI service offerings such as calibration options repair and replacement Visit ni com register to register your NI product Product registration facilitates...

Отзывы: