background image

NI corporate headquarters is located at
11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI
also has offices located around the world. For telephone support
in the United States, create your service request at 

ni.com/support

or dial 1 866 ASK MYNI (275 6964). For telephone support
outside the United States, visit the 

Worldwide Offices

 section of 

ni.com/niglobal

 to access the branch office websites, which

provide up-to-date contact information, support phone numbers,
email addresses, and current events.

Refer to the NI Trademarks and Logo Guidelines at 

ni.com/trademarks

 for information on NI

trademarks. Other product and company names mentioned herein are trademarks or trade names
of their respective companies. For patents covering NI products/technology, refer to the
appropriate location: 

Help

»

Patents in your software, the 

patents.txt

 file on your media, or the

National Instruments Patent Notice at 

ni.com/patents

. You can find information about end-user

license agreements (EULAs) and third-party legal notices in the readme file for your NI product.
Refer to the Export Compliance Information at 

ni.com/legal/export-compliance

 for the NI

global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/
export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF
THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS.
U.S. Government Customers: The data contained in this manual was developed at private
expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR
52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

© 2009—2016 National Instruments. All rights reserved.

375206D-01

Sep16

Содержание NI-9207

Страница 1: ...GETTING STARTED GUIDE NI 9207 16 AI 20 mA 10 V 24 Bit 500 S s Aggregate...

Страница 2: ...o the NI 9207 The other components in the system might not meet the same safety ratings Refer to the documentation for each component in the system to determine the safety and EMC ratings for the enti...

Страница 3: ...0 Vrms verified by a 5 s dielectric withstand test Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system This category refers to lo...

Страница 4: ...thstand test Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage MAINS is a hazardous live electr...

Страница 5: ...for Hazardous Locations The NI 9207 is suitable for use in Class I Division 2 Groups A B C D T4 hazardous locations Class I Zone 2 AEx nA IIC T4 and Ex nA IIC T4 hazardous locations and nonhazardous l...

Страница 6: ...minal has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 12 ATEX 1202658X and is IECEx UL 14 0089X certified The NI 9207 with DSUB has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO...

Страница 7: ...as defined in IEC EN 60079 15 Caution The enclosure must have a door or cover accessible only by the use of a tool Electromagnetic Compatibility Guidelines This product was tested and complies with th...

Страница 8: ...re any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules Caution To ensure the specified...

Страница 9: ...icate or look for the Lloyd s Register mark on the product Caution In order to meet the EMC requirements for marine applications install the product in a shielded enclosure with shielded and or filter...

Страница 10: ...ications Operating temperature IEC 60068 2 1 IEC 60068 2 2 40 C to 70 C Operating humidity IEC 60068 2 78 10 RH to 90 RH noncondensing Pollution Degree 2 Maximum altitude 5 000 m Indoor use only Note...

Страница 11: ...1 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 COM AI14 AI12 AI10 AI8 AI6 AI4 AI2 AI0 COM AI15 AI13 AI11 AI9 AI7 AI5 AI3 AI1 Vsup Vsup Vsup Vsup Vsup AI6 AI4 AI2 AI0 V...

Страница 12: ...n AI Positive analog input voltage connection AI Negative analog input signal connection AI Analog input current connection Vsup Voltage supply connection COM Common reference connection to isolated g...

Страница 13: ...Floating Differential Connections 1 M Resistor NI 9207 AI0 AI0 COM Voltage Source Grounded Connections Voltage Source AI0 AI0 COM NI 9207 NI 9207 Getting Started Guide National Instruments 13...

Страница 14: ...th a 0 to 30 V voltage range to the NI 9207 This power supply provides the current for the devices you connect to the module You can connect only one external voltage supply to the NI 9207 1 Connect t...

Страница 15: ...nal power supply connected to the Vsup and COM pins is powered on Connecting a Loop Powered Current Transducer NI 9207 AI0 External Power Supply Loop Powered Current Transducer Vsup COM Vsup 2 A Max N...

Страница 16: ...Connecting a Three Wire Current Transducer Three Wire Current Transducer NI 9207 COM AI8 External Power Supply Vsup COM Vsup 2 A Max OUT 16 ni com NI 9207 Getting Started Guide...

Страница 17: ...ire with a ferrule Open the terminal by pressing the push button when using stranded wire without a ferrule High Vibration Application Connections If your application is subject to high vibration NI r...

Страница 18: ...Series Documentation Resources ni com info cseriesdoc Services ni com services NI 9207 Datasheet NI RIO Help LabVIEW FPGA Help NI 9207 Datasheet NI DAQmx Help LabVIEW Help Installs with the software L...

Страница 19: ...duct Product registration facilitates technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council o...

Страница 20: ...cts technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find information a...

Отзывы: