background image

LED Pattern

Indication

by enabling safe mode in MAX. Refer to the Measurement & Automation

Explorer (MAX) Help for information about safe mode.

Blinks four times

and pauses

The NI-9147 is in safe mode. The software has crashed twice without

rebooting or cycling power between crashes.

Continuously blinks The NI-9147 has detected an unrecoverable error. Contact NI for support.
On momentarily

The NI-9147 is booting. No action required.

Off

The NI-9147 is in run mode. Software is installed and the operating system is

running.

Table 3. STATUS LED Indicators

Where to Go Next

APPLICATION

SUPPORT

NI Community

ni.com/community

NI CompactRIO
Developer’s Guide
ni.com/compactriodevguide

Software Support

ni.com/info swsupport

Support

ni.com/support

SOFTWARE

CompactRIO Sample
Projects
LabVIEW Create Project

HARDWARE

NI 9147
Specifications
ni.com/manuals

NI 9147
User Manual
ni.com/manuals

C Series Getting
Started Guides
ni.com/manuals

Configuring a Project
NI-RIO Help

Learn LabVIEW Basics
ni.com/gettingstarted

CompactRIO Examples
NI Example Finder

Services

ni.com/services

NI Services

Visit 

ni.com/support

 to find support resources including documentation,

downloads, and troubleshooting and application development self-help such as

tutorials and examples.

© National Instruments

17

NI-9147 Getting Started

Содержание NI 9147

Страница 1: ...NI 9147 Getting Started 2022 07 06...

Страница 2: ...ies Modules 7 Removing C Series Modules 8 Connecting the NI 9147 8 Connecting the NI 9147 to Ground 8 Connecting the NI 9147 to Power 9 Connecting the NI 9147 to the Host Computer 11 Configuring the S...

Страница 3: ...s en garde de la documentation utilisateur L utilisation d un mod le de toute autre fa on que celle sp cifi e risque de l endommager et de compromettre la protection de s curit int gr e Renvoyez les m...

Страница 4: ...vision 2 or Zone 2 Caution The system must be installed in an enclosure certified for the intended hazardous classified location having a tool secured cover door where a minimum protection of at least...

Страница 5: ...This product is intended for use in industrial locations However harmful interference may occur in some installations when the product is connected to a peripheral device or test object or if the pro...

Страница 6: ...C 60068 2 2 40 C to 70 C Operating humidity IEC 60068 2 78 10 RH to 90 RH noncondensing Pollution Degree 2 Maximum altitude 5 000 m Indoor use only Note Refer to the device specifications on ni com ma...

Страница 7: ...following application software and device drivers on the host computer in this order 1 LabVIEW 2014 SP1 or later 2 LabVIEW FPGA Module 2014 SP1 or later 3 NI RIO Device Drivers 14 5 or later For minim...

Страница 8: ...hes lock in place Removing C Series Modules Verify that power is not connected to the I O connector s on the C Series module before you remove a module from the NI 9147 If the system is in a nonhazard...

Страница 9: ...module with a plastic connector you must attach the cable shield to the chassis grounding terminal using 2 1 mm2 14 AWG or larger wire Attach a ring lug to the wire and attach the wire to the chassis...

Страница 10: ...PS 15 Industrial Power Supply 24 V DC 5 A 100 V AC to 120 V AC 200 V AC to 240 V AC input 781093 01 Table 2 NI Power Supplies What to Do Complete the following steps to connect a power supply to the...

Страница 11: ...wice every few seconds Related reference STATUS LED Indicators Connecting the NI 9147 to the Host Computer Complete the following steps to connect the NI 9147 to the host computer using the USB device...

Страница 12: ...the model number followed by the serial number such as NI cRIO 9147 1856AAA Setting a System Password Complete the following steps to set a system password Note The default username for the NI 9147 i...

Страница 13: ...following steps to install software on the NI 9147 1 In MAX expand your system under Remote Systems 2 Right click Software 3 Select Add Remove Software to launch the LabVIEW Real Time Software Wizard...

Страница 14: ...computer The USB driver creates a virtual network interface card and assigns an IP address to the NI 9147 in the format of 172 22 11 x 2 In MAX expand your system under Remote Systems 3 Select the Ne...

Страница 15: ...three times every few seconds 2 Set a new DHCP connection by holding the RESET button down for 5 seconds The STATUS LED repeats the same behavior from Step 1 If the NI 9147 fails to set a new DHCP ad...

Страница 16: ...afe Mode STATUS LED Indicators The following table describes the STATUS LED indicators LED Pattern Indication Blinks twice and pauses The NI 9147 is in safe mode Software is not installed which is the...

Страница 17: ...Where to Go Next APPLICATION SUPPORT NI Community ni com community NI CompactRIO Developer s Guide ni com compactriodevguide Software Support ni com info swsupport Support ni com support SOFTWARE Comp...

Страница 18: ...com register to register your NI product Product registration facilitates technical support and ensures that you receive important information updates from NI NI corporate headquarters is located at...