NI myDAQ User Guide and Specifications
28
ni.com
Example: Measuring a Signal Using the NI ELVISmx Oscilloscope SFP
with NI myDAQ
Complete the following steps to measure a signal with the NI ELVISmx
Scope SFP.
Note
Before opening a SFP, make sure that the NI myDAQ device is connected to the
system and is ready to use. After the NI myDAQ is connected to the system, the blue LED
lights, indicating the device is ready for use.
1.
Connect the signal(s) you want to measure to the connector(s) on the
side of the NI myDAQ device.
2.
Launch the NI ELVISmx Scope SFP from the NI ELVISmx Instrument
Launcher.
3.
Click
Run
. You should see the signal in the Display Window.
4.
If necessary, adjust the controls to stabilize the signal in the graph. Adjust
the Time/Div, Vertical Position, Scale, and other controls as desired.