© National Instruments
|
B-11
MXI-Express x1 Series User Manual
Power Requirements
Environment
Maximum altitude
2,000 m
Pollution Degree
2
Indoor use only.
Operating Environment
Ambient temperature range
0 to 55 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Operating relative humidity
10 to 90%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
Storage Environment
Ambient temperature range
-40 to 70 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Storage relative humidity
5 to 95%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
Safety
This product is designed to meet the requirements of the following standards of safety for
electrical equipment for measurement, control, and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 61010-1, CSA 61010-1
Note
For UL and other safety certifications, refer to the product label or the
section.
Power Rail
Typical Current
Maximum Current
+3.3 V
580 mA
1.040 A
+3.3 VAux
10 mA
50 mA
+12 V
0 A
0 A