Appendix A
Specifications for PXI-8320
©
National Instruments Corporation
A-7
MXI-2 Configuration Reference Manual
PXI-8320
This section lists the specifications for the PXI-8320 module.
MXIbus Capability Descriptions
•
Master-mode A32, A24, and A16 addressing
•
Master-mode block transfers and synchronous block transfers
•
Slave-mode A32, A24, and A16 addressing
•
Slave-mode block transfers and synchronous block transfers
•
Master-mode D32, D16, and D08 data sizes
•
Slave-mode D32, D16, and D08 data sizes
•
Optional MXIbus System Controller
•
Can be a fair MXIbus requester
•
Can lock the MXIbus for indivisible transfers
•
Can terminate the MXIbus
•
MXIbus master retry support
•
MXIbus slave retry support
•
Interrupt handler for levels 7 to 1
•
Interrupt requester for levels 7 to 1
•
MXIbus D32, D16, D08(O) interrupt handler
•
MXIbus D32, D16, D08(O) interrupter
•
Release on Acknowledge or Register Access interrupter
•
MXIbus bus timer (programmable limit)
•
Automatic MXIbus System Controller detection
PCI Functionality
PCI initiator (master) capability............. supported
PCI target (slave) capability................... supported
Data path ................................................ 32 bits
Card voltage/type ................................... 5 V only; 32-bit 3U-size card
Parity generation/checking
error reporting ........................................ supported