background image

 

Important Information

Warranty

The NI PCIe-836

x

 and NI PXI-8360 is warranted against defects in materials and workmanship for a period of one year from the date of 

shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to 
be defective during the warranty period. This warranty includes parts and labor. 

The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in 
materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments 
will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects 
during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free.

A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before any 
equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are covered by 
warranty.

National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical accuracy. In 
the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent editions of this document 
without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected. In no event shall National 
Instruments be liable for any damages arising out of or related to this document or the information contained in it.

E

XCEPT

 

AS

 

SPECIFIED

 

HEREIN

, N

ATIONAL

 I

NSTRUMENTS

 

MAKES

 

NO

 

WARRANTIES

EXPRESS

 

OR

 

IMPLIED

AND

 

SPECIFICALLY

 

DISCLAIMS

 

ANY

 

WARRANTY

 

OF

 

MERCHANTABILITY

 

OR

 

FITNESS

 

FOR

 

A

 

PARTICULAR

 

PURPOSE

. C

USTOMER

S

 

RIGHT

 

TO

 

RECOVER

 

DAMAGES

 

CAUSED

 

BY

 

FAULT

 

OR

 

NEGLIGENCE

 

ON

 

THE

 

PART

 

OF

 N

ATIONAL

 

I

NSTRUMENTS

 

SHALL

 

BE

 

LIMITED

 

TO

 

THE

 

AMOUNT

 

THERETOFORE

 

PAID

 

BY

 

THE

 

CUSTOMER

. N

ATIONAL

 I

NSTRUMENTS

 

WILL

 

NOT

 

BE

 

LIABLE

 

FOR

 

DAMAGES

 

RESULTING

 

FROM

 

LOSS

 

OF

 

DATA

PROFITS

USE

 

OF

 

PRODUCTS

OR

 

INCIDENTAL

 

OR

 

CONSEQUENTIAL

 

DAMAGES

EVEN

 

IF

 

ADVISED

 

OF

 

THE

 

POSSIBILITY

 

THEREOF

. This limitation of 

the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including negligence. Any action against 
National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in 
performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service 
failures caused by owner’s failure to follow the National Instruments installation, operation, or maintenance instructions; owner’s modification of the 
product; owner’s abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside 
reasonable control.

Copyright

Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, 
recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National 
Instruments Corporation.

National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other 
intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only 
to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.

Trademarks

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the 

Terms of Use

 section 

on

ni.com/legal

 for more information about National Instruments trademarks.

Other product and company names mentioned herein are trademarks or trade names of their respective companies.

Members of the National Instruments Alliance Partner Program are business entities independent from National Instruments and have no agency, 
partnership, or joint-venture relationship with National Instruments.

Patents

For patents covering National Instruments products, refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file 

on your CD, or 

ni.com/patents

.

WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS

(1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF 
RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN 
ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT 
INJURY TO A HUMAN.

(2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE 
IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY, 
COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS 
AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND HARDWARE 
COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL DEVICES, 
TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR MISUSES, OR 
ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE HEREAFTER 
COLLECTIVELY TERMED “SYSTEM FAILURES”). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD CREATE A RISK OF 
HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD NOT BE RELIANT SOLELY 
UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID DAMAGE, INJURY, OR DEATH, 
THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO PROTECT AGAINST SYSTEM FAILURES, 
INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS. BECAUSE EACH END-USER SYSTEM IS 
CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION 
DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT 
EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY 
RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER 
NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT 
LIMITATION, THE APPROPRIATE DESIGN, PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.

Содержание Multisystem eXtension Interface NI PCIe-836x

Страница 1: ...M MXI Express Series User Manual MXI Express Multisystem eXtension Interface for PCI Express Compact PCI and PXI Bus Computers NI PCIe 836x NI PXI 8360 MXI Express Series User Manual March 2008 371452...

Страница 2: ...ebanon 961 0 1 33 28 28 Malaysia 1800 887710 Mexico 01 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway 47 0 66 90 76 60 Poland 48 22 3390150 Portugal 351 210 311 210 Russia 7...

Страница 3: ...cal including photocopying recording storing in an information retrieval system or translating in whole or in part without the prior written consent of National Instruments Corporation National Instru...

Страница 4: ...t Started 1 4 Unpacking 1 4 Chapter 2 Hardware Installation Hardware Installation 2 1 Installing an NI PCIe 836x 2 1 Installing an NI PXI 8360 2 3 Cabling 2 4 Powering Up the MXI Express System 2 5 Po...

Страница 5: ...Contents MXI Express Series User Manual vi ni com Appendix A Specifications Appendix B Common Questions Appendix C Technical Support and Professional Services Glossary Index...

Страница 6: ...ications for information about precautions to take bold Bold text denotes items that you must select or click in the software such as menu items and dialog box options Bold text also denotes parameter...

Страница 7: ...helpful as you read this manual Set Up Your MXI Express System Your computer or chassis documentation PXI Hardware Specification Revision 2 1 PXI Software Specification Revision 2 1 PCI Specification...

Страница 8: ...the remainder of this manual the term MXI Express card refers to any product in the MXI Express series About the MXI Express Series Description and Features MXI Express functions as a cabled PCI Expr...

Страница 9: ...om Basic MXI Express System The simplest MXI Express system consists of an NI PCIe 836x in a PC connected to an NI PXI 8360 in the controller slot of a PXI CompactPCI chassis as shown in Figure 1 1 Fi...

Страница 10: ...PXI CompactPCI chassis If multiple PCI Express slots are available in the host PC additional PXI chassis can be connected by installing an NI PCIe 836x in any available PCI Express slot Figure 1 2 sho...

Страница 11: ...the PCI Express Specification Revision 1 0a or later Unpacking Your MXI Express cards are shipped in antistatic packages to prevent electrostatic damage ESD to the devices ESD can damage several comp...

Страница 12: ...6x The power cord grounds the chassis and protects it from electrical damage while you install the card Caution To protect both yourself and the computer from electrical hazards your computer should r...

Страница 13: ...t might be on your clothes or body 6 Line up the NI PCIe 836x with the slot on the back panel Slowly push down on the top of the NI PCIe 836x until its card edge connector is resting on the expansion...

Страница 14: ...city that might be on your clothes or body 5 Make sure the injector ejector handle is in its downward position Be sure to remove all connector packaging and protective caps from retaining screws on th...

Страница 15: ...ds The cables have no polarity so either end may be connected to either card Caution Do not remove the cable after the system is powered on Doing so can hang or cause errors in applications communicat...

Страница 16: ...ans that all of the expansion chassis must be turned on before the host PC for the BIOS and OS to correctly configure a MXI Express system Note There are no requirements on how MXI Express expansion c...

Страница 17: ...nsparent to device drivers so no additional software is needed to support using PXI and CompactPCI devices in a chassis connected using MXI Express The link between the PC and the chassis is a x1 cabl...

Страница 18: ...ed PCI Express connector The PXI 8360 architecture is the same as in Figure 3 1 Figure 3 2 MXI Express Block Diagram with NI PCIe 8361 NI PCIe 8362 PCI Express Switch Cabled PCI Express Connector PXI...

Страница 19: ...cted to the two cabled PCI Express connectors Cabled PCI Express Connector The cabled PCI Express connector provides all necessary signals to connect an NI PCIe 836x and an NI PXI 8360 These signals i...

Страница 20: ...nstruments Color Meaning Off Power is off Red Power is out of spec Amber Power is within spec no link to chassis Green Power is within spec link established LED Color Meaning PWR Off No power Red Powe...

Страница 21: ...CIe 8361 6 7 7 1 cm 2 6 2 8 in NI PCIe 8362 10 7 17 5 cm 4 4 6 9 in Maximum cable length 7 m Slot requirements NI PXI 8360 One system slot NI PCIe 8361 One slot PCI Express standard height or low prof...

Страница 22: ...ing Environment Ambient temperature range 0 to 55 C tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Power Rail Typical Current Maximum Current 3 3 V 1 500 A 1 750 A 5 V 5 mA 20 mA 12 V 5 mA...

Страница 23: ...h IEC 60068 2 56 Shock and Vibration Operational shock 30 g peak half sine 11 ms pulse Tested in accordance with IEC 60068 2 27 Test profile developed in accordance with MIL PRF 28800F Random Vibratio...

Страница 24: ...rs and filler panels must be installed Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement control and laboratory use...

Страница 25: ...cts in an environmentally responsible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial not only to the environment but also to NI customers For additi...

Страница 26: ...o 255 bus segments MXI Express does not limit this number but the maximum number of bus segments allowed can be BIOS or operating system dependent Also a computer may already have several PCI bus segm...

Страница 27: ...and the operating system will provide a mechanism for you to ignore the MXI Express configuration device that is built into the MXI Express hardware MXI 3 required optimization software Does MXI Expre...

Страница 28: ...ard be used together directly No MXI 3 MXI 4 and MXI Express boards use different cable connectors and cannot be connected together Additionally the board to board communication protocols differ Can I...

Страница 29: ...with MXI Express multiple chassis are connected in parallel and can be powered on in any order except that you need to ensure that the last component powered on is the host PC For more details refer...

Страница 30: ...rd Service Program Membership This program entitles members to direct access to NI Applications Engineers via phone and email for one to one technical support as well as exclusive access to on demand...

Страница 31: ...oduct by visiting ni com certification Calibration Certificate If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration If you searched ni...

Страница 32: ...dividual circuitry in a computer Typically a bus is the expansion vehicle to which I O or other devices are connected Examples of PC buses are the AT bus NuBus Micro Channel and EISA bus bus master A...

Страница 33: ...s manufactured I IEEE Institute of Electrical and Electronics Engineers P PCI Peripheral Component Interconnect A high performance expansion bus architecture originally developed by Intel to replace I...

Страница 34: ...Glossary National Instruments Corporation G 3 MXI Express Series User Manual X x1 A link or port with one physical lane...

Страница 35: ...software B 2 MXI 3 to MXI Express B 3 configuration additional star figure 1 3 configuration basic figure 1 2 conventions used in the manual vii D Declaration of Conformity NI resources C 2 diagnosti...

Страница 36: ...on 1 1 getting started 1 4 N National Instruments support and services C 1 NI PCIe 836x installation 2 1 figure 2 2 NI PXI 8360 installation 2 3 figure 2 4 NI support and services C 1 O operating envi...

Страница 37: ...A 3 NI PXI 8360 A 2 environmental management A 5 physical A 1 safety A 4 waste electrical and electronic equipment A 5 storage environment specifications NI PCIe 836x A 4 NI PXI 8360 A 3 T technical...

Отзывы: