Signal Connections
Chapter 3
Lab-PC+ User Manual
3-20
© National Instruments Corporation
Mode 2 Bidirectional Timing
The timing specifications for bidirectional transfers in Mode 2 are as follows:
T1
T6
T7
T3
T4
T10
T2
T5
T8
T9
WR *
OBF *
INTR
ACK *
STB *
IBF
RD *
DATA
Name
Description
Minimum
Maximum
T1
WR* = 1 to OBF* = 0
–
650
T2
Data before STB* = 1
0
–
T3
STB* pulse width
500
–
T4
STB* = 0 to IBF = 1
–
300
T5
Data after STB* = 1
180
–
T6
ACK* = 0 to OBF = 1
–
350
T7
ACK* pulse width
300
–
T8
ACK* = 0 to output
–
300
T9
ACK* = 1 to output float
20
250
T10
RD* = 1 to IBF = 0
–
300
All timing values are in nanoseconds.