6
ni.com
Clocks
Pixel clock frequency range...................................20 KHz to 50 MHz
PCI Interface
Theoretical max PCI bandwidth ............................133 MB/s
Serial Interface
Signaling standard..................................................RS-232
Baud rates supported..............................................300, 600, 1200, 1800, 2000, 2400, 3600, 4800, 7200,
or 9600 bps; 19.2, 38.4, or 56 kbps
Data bits .................................................................5, 6, 7, or 8 bits
Parity ......................................................................Odd, even, or disabled
Stop bit ...................................................................Enabled or disabled
Data transmit ready polarity ..................................Active high or active low
Ready-to-send polarity...........................................Active high or active low
Power Requirements
Voltage ...................................................................+ 5 V (2.135 A)
+12 V (250 mA)
–12 V (100 mA)
Physical
Dimensions ............................................................106.68 cm
×
312 cm (4.2 in.
×
12.283 in.)
Weight ....................................................................1.1 kg (0.5 lb)
Environment
The NI 1424 device is intended for indoor use only.
Operating temperature ...........................................0 °C to 55 °C
Storage temperature ...............................................–20 °C to 70 °C
Relative humidity...................................................5% to 90%, noncondensing
Pollution Degree ....................................................2
Approved at altitudes up to 2,000 m.
Safety
This product is designed to meet the requirements of the following standards of safety for electrical
equipment for measurement, control, and laboratory use:
•
IEC 61010-1, EN-61010-1
•
UL 61010-1, CSA 61010-1
Note
For UL and other safety certifications, refer to the product label or visit
ni.com/
certification
, search by model number or product line, and click the appropriate link
in the Certification column.