background image

Restoring the NI Linux Real-Time Operating System

Complete the following steps to restore the NI Linux Real-Time operating system to its factory
default condition. These steps do not restore the BIOS settings to factory default. Use the

Restore Defaults

 option in the 

Save & Exit Menu

 of the BIOS setup utility to restore the BIOS

settings.

Caution

 

Restoring the operating system erases the contents of the hard drive. Back

up any files you want to keep before restoring the hard drive.

1.

Start the IC-3121 in safe mode. To start in safe mode, apply power, turn on the device,
press the RESET button for more than 5 seconds, then release the button.

2.

Launch NI MAX on the development computer.

3.

In the MAX configuration tree, expand 

Remote Systems

.

4.

Right-click the name of the IC-3121 you want to restore and select 

Format Disk

.

5.

Enter the username and password for the device. By default, the username is 

admin

 and

the password field is blank.

6.

Click 

Format

.

7.

After formatting is complete, a confirmation dialog window appears. Click 

Close

.

8.

Refer to the 

IC-3121 Getting Started Guide

 for information about installing software and

configuring the device.

Related Information

Safe Mode

 on page 18

Restoring the Windows Operating System

You can restore the Windows operating system on the hard drive of the IC-3121 from the
reinstallation DVD shipped with device.

Note

 

Restoring the operating system erases the contents of the hard drive. Back up

any files you want to keep before restoring the hard drive.

Creating a Bootable USB Flash Drive

You can create a bootable USB flash drive from the reinstallation DVD if you do not have a
USB DVD drive to connect to the IC-3121. The USB flash drive must be at least 8 GB. Ensure
the USB flash drive appears as a Removable Drive in Windows. Avoid using drives that
appear as Fixed Disk drives. Complete the following steps to prepare the USB flash drive for
recovery.

Note

 

If you have an external USB DVD drive, you can use the external DVD drive

to restore Windows without creating a bootable USB flash drive. Proceed to the next
section if you are using an external DVD drive.

1.

Insert the USB flash drive into a computer with a DVD drive running Windows, and wait
for the flash drive to be recognized.

2.

Open a command prompt as an administrator.

24

  | 

ni.com

  | 

IC-3121 User Manual

Содержание IC-3121

Страница 1: ...struments IC 3121 Manual Get Pricing Availability at ApexWaves com Call Today 1 800 915 6216 Email sales apexwaves com https www apexwaves com modular systems national instruments industrial controlle...

Страница 2: ...ing System 24 Restoring the Windows Operating System 24 Mounting the IC 3121 26 Securing the IC 3121 to a Mount 30 Clearance Requirements 30 Where to Go Next 31 Worldwide Support and Services 32 Hardw...

Страница 3: ...l Port 3 USB 2 0 Ports 4 Gigabit Ethernet Port 5 USB 3 0 Ports 6 44 pin Digital I O Connector Connector Pinouts The IC 3121 provides the following connectors Chassis Grounding Screw Use the grounding...

Страница 4: ...ed outputs The same power supply may be used for both the system power and isolated outputs power if isolation is not required and the power supply meets the voltage and power requirements for both in...

Страница 5: ...lf accordingly A CAT 5e or CAT 6 1000Base T Ethernet cable is required to achieve 1 000 Mbps Gigabit Ethernet performance CAT 5 Ethernet cables are not guaranteed to meet the necessary requirements Wh...

Страница 6: ...A 7 No Connect BI_DD BI_DC 8 No Connect BI_DD BI_DC USB 2 0 Ports The USB ports support common USB peripheral devices such as USB flash drives USB hard drives USB to IDE adapters keyboards mice and US...

Страница 7: ...s a 10 position RJ50 modular jack which can connect to serial devices such as PLCs scanners and lighting devices NI recommends the following serial cables for the IC 3121 Cable Part Number RJ50 10 pos...

Страница 8: ...21 VGA Port Use the VGA port to connect a monitor to the IC 3121 Use any standard 15 pin VGA cable to access the VGA port The VGA port has a maximum resolution of 1920 x 1200 at 60 Hz Figure 7 VGA Por...

Страница 9: ...ral devices such as USB flash drives USB hard drives USB to IDE adapters keyboards mice and USB cameras RT only LabVIEW usually maps USB mass storage devices to the U V W or X drive starting with the...

Страница 10: ...NI recommends the following digital I O cables for the IC 3121 Cable Part Number 44 pin D sub male to pigtail cable 156083 03 for 3 meter cable 44 pin D sub male to 44 position D sub female cable 1560...

Страница 11: ...so Out 4 General purpose isolated output 16 Diff 0 Bidirectional RS 422 I O negative side or quadrature encoder phase A 17 GND Digital ground reference for TTL and differential I O 18 TTL 4 Bidirectio...

Страница 12: ...round reference for isolated inputs and outputs 40 Iso In 6 General purpose isolated input 41 Iso In 7 General purpose isolated input 42 CISO Common ground reference for isolated inputs and outputs 43...

Страница 13: ...ductive load The following image shows an example of an isolated output wired to an external load with a flyback diode installed across the load Caution Do not draw more than 35 mA from each isolated...

Страница 14: ...ff I O 1 3 3 V 10 k 10 k 10 k 10 k EN EN 7 5 k 7 5 k 7 5 k 7 5 k Figure 13 Connecting Differential Line Drivers Diff In 0 Diff In 0 Phase A Phase A Diff In 1 Diff In 1 Phase B Phase B External Device...

Страница 15: ...In 1 Diff In 1 Phase B External Device Industrial Controller TTL I O The following image shows the circuit for a bidirectional TTL I O Figure 15 TTL Input Output Circuit 100 TTL_OUT TTL_OE TTL_IN 10 k...

Страница 16: ...SET DIGITAL I O 10 100 1000 ACT LINK USER1 USER2 PWR FAULT STATUS 0 1 USER1 USER2 PWR FAULT STATUS IC 3121 Industrial Controller The following table describes the LEDs and indications IC 3121 User Man...

Страница 17: ...about the safe mode state 4 blinks RT only The IC 3121 has experienced two consecutive software exceptions The IC 3121 automatically restarts after an exception After the second exception the IC 3121...

Страница 18: ...hat can be controlled using the NI System Configuration API Related Information Safe Mode on page 18 Ethernet LEDs The Gigabit Ethernet port has the following LEDs Figure 17 LEDs for the Gigabit Ether...

Страница 19: ...to enable IP reset which resets the network adapter to its default configuration Safe Mode When you boot the IC 3121 into safe mode it launches only the services necessary for updating its configurat...

Страница 20: ...Drivers include a reconfigurable I O personality that you can use out of the box Install the following software if you need to compile a custom personality for your application LabVIEW 2014 SP1 or lat...

Страница 21: ...default values Press F1 from any root menu to display more information about navigating the BIOS setup program Menu items listed in blue are changeable menu items in gray are not changeable A blue tr...

Страница 22: ...rations to the USB ports Normally you do not need to modify these settings as the factory default settings provide the most compatible and optimal configuration possible Legacy USB Support Specifies w...

Страница 23: ...figuration options To select a boot device press Enter on the desired configuration on the desired configuration option and select a boot device from the resulting menu You can also disable certain bo...

Страница 24: ...hen exits and reboots the controller Discard Changes and Reset Any changes made to BIOS settings during this session of the BIOS setup utility since the last save are discarded The setup utility then...

Страница 25: ...1 Getting Started Guide for information about installing software and configuring the device Related Information Safe Mode on page 18 Restoring the Windows Operating System You can restore the Windows...

Страница 26: ...ree volume letter where free volume letter is a letter not currently associated with any disk drives For example assign letter K 12 Copy the contents of the reinstallation DVD to the root of the USB f...

Страница 27: ...mount for the IC 3121 If you do not want to create a custom mount a panel and DIN rail mount kit for the IC 3121 is available from National Instruments part number 781740 01 Caution If you choose not...

Страница 28: ...mm 0 667 in 17 11 mm 0 674 in 26 78 mm 1 054 in 27 56 mm 1 085 in 21 19 mm 0 834 in 15 07 mm 0 593 in 38 75 mm 1 526 in 9 51 mm 0 374 in 40 77 mm 1 605 in 26 7 mm 1 051 in 24 17 mm 0 951 in 17 21 mm 0...

Страница 29: ...iew with Dimensions in inches millimeters 23 46 mm 0 924 in 54 48 mm 2 145 in 23 24 mm 0 915 in 37 50 mm 1 476 in 19 41 mm 0 764 in 24 46 mm 0 963 in 25 92 mm 1 020 in 10 58 mm 0 417 in 28 ni com IC 3...

Страница 30: ...Figure 21 Side View with Dimensions in inches millimeters 130 38 mm 5 133 in 108 47 mm 4 270 in 3 80 mm 0 150 in 104 67 mm 4 121 in IC 3121 User Manual National Instruments 29...

Страница 31: ...t two 6 32 screws and tighten them until they are secure 3 5 in lb Make sure the heads of the screws are flush with the mounting bracket Clearance Requirements The IC 3121 installation must meet the f...

Страница 32: ...121 in an application Refer to the National Instruments Product Manuals Library at ni com manuals for the most recent versions of product documentation IC 3121 Specifications Contains detailed specifi...

Страница 33: ...MYNI 275 6964 For telephone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information...

Отзывы: