Chapter 2
Installation and Configuration
2-10
©
National Instruments Corporation
Configure the Slide Switch
Your GPIB-ENET has two network interface connectors: a 15-pin AUI
connector, and either a 10Base-T Ethernet connector or a coax Ethernet
connector. Use the slide switch to select the connector the GPIB-ENET
uses. The default switch setting is either 10Base-T or coax. Figure 2-9
depicts the default setting for the different types of GPIB-ENET boxes.
Figure 2-9. Default Switch Setting for Ethernet Port Configuration
If you want to use the AUI connector, change the switch setting to
match the appropriate setting, as shown in Figure 2-10.
Figure 2-10. Switch Setting for AUI Ethernet Port Configuration
Configure the 8-Bit DIP Switch
The 8-bit DIP switch selects the operating mode of the GPIB-ENET.
The GPIB-ENET is shipped to you with the DIP switches set for normal
operation mode. In normal operation mode, all the switches are in the
OFF position. Most customers use the GPIB-ENET in normal operating
mode. Do not change the DIP switch settings unless you run a
GPIB-ENET utility that prompts you to change them. For information
about the 8-bit DIP switch, refer to Appendix B,
10Base-T
COAX
OR
AUI
AUI
10Base-T
COAX
OR
AUI