D-2
|
ni.com
Appendix D
Specifications
Operational Characteristics
Architecture ......................................................Point-to-point (not multi-drop) transmission
Operating modes ...............................................Buffered or unbuffered (interlocked) mode
HS488 modes....................................................Enabled HS488 or disabled HS488 mode
Parallel Poll Response modes ...........................Immediate Parallel Poll Response mode or
latched Parallel Poll Response mode
Electrical Characteristics
Transmission interface unit
GPIB-140A ...............................................Optical transmitter and receiver
(HFBR1414, HFBR2416, or equivalent) with
ST-style optical cable connectors
GPIB-140A/2 ............................................Optical transmitter and receiver
(HFBR1312, HFBR1316, or equivalent) with
ST-style optical cable connectors
GPIB interface load ..........................................Two standard loads, AC and DC
Power supply unit
100-120 VAC ............................................50-60 Hz
220-240 VAC ............................................50-60 Hz
Maximum current requirement
100-120 VAC ............................................135 mA
220-240 VAC ............................................100 mA
Fuse rating and type
100-120 VAC ............................................T 0.5A 250V
220-240 VAC ............................................T 0.3A 350V
Environmental Characteristics
Operating temperature ......................................0 to 40 °C
Storage temperature ..........................................-20 to 70 °C