National Instruments FieldPoint cFP-RTD-122 Скачать руководство пользователя страница 15

© 

National Instruments Corp.

15

FP-RTD-122 and cFP-RTD-122

Go to 

ni.com/support

 for the most current manuals, examples, 

and troubleshooting information. 

For telephone support in the United States, create your service 
request at 

ni.com/ask

 and follow the calling instructions or dial 

512 795 8248. For telephone support outside the United States, 
contact your local branch office: 

Australia 61 2 9672 8846,  Austria 43 0 662 45 79 90 0, 
Belgium 32 0 2 757 00 20,  Brazil 55 11 3262 3599, 
Canada (Calgary) 403 274 9391, 
Canada (Montreal) 514 288 5722, 
Canada (Ottawa) 613 233 5949, Canada (Québec) 514 694 8521, 
Canada (Toronto) 905 785 0085, 
Canada (Vancouver) 514 685 7530, China 86 21 6555 7838, 
Czech Republic 420 2 2423 5774, Denmark 45 45 76 26 00, 
Finland 385 0 9 725 725 11, France 33 0 1 48 14 24 24, 
Germany 49 0 89 741 31 30, Greece 30 2 10 42 96 427, 
Hong Kong 2645 3186, India 91 80 51190000, 
Israel 972 0 3 6393737, Italy 39 02 413091, 
Japan 81 3 5472 2970, Korea 82 02 3451 3400, 
Malaysia 603 9059 6711, Mexico 001 800 010 0793, 
Netherlands 31 0 348 433 466, New Zealand 64 09 914 0488, 
Norway 47 0 32 27 73 00,  Poland 48 0 22 3390 150, 
Portugal 351 210 311 210, Russia 7 095 238 7139, 
Singapore 65 6 226 5886, Slovenia 386 3 425 4200, South 
Africa 27 0 11 805 8197,  Spain 34 91 640 0085, 
Sweden 46 0 8 587 895 00, Switzerland 41 56 200 51 51, 
Taiwan 886 2 2528 7227, United Kingdom 44 0 1635 523545

Содержание FieldPoint cFP-RTD-122

Страница 1: ...how to install and use the National Instruments FP RTD 122 and cFP RTD 122 three wire RTD and resistance input modules referred to inclusively as the c FP RTD 122 For details on configuring and acces...

Страница 2: ...r position 1 used for the FP RTD 122 module 2 Align the FP RTD 122 alignment slots with the guide rails on the terminal base 3 Press firmly to seat the FP RTD 122 on the terminal base When the module...

Страница 3: ...he cFP RTD 122 prevent backward insertion 2 Press firmly to seat the cFP RTD 122 on the backplane 3 Using a number 2 Phillips screwdriver with a shank of at least 64 mm 2 5 in length tighten the capti...

Страница 4: ...ield to the COM terminal Do not connect the shield to any of the wires at the signal end Taking RTD Measurements with the c FP RTD 122 The c FP RTD 122 has eight input channels All eight channels shar...

Страница 5: ...xcitation wire to the EX terminal of the module and connect the other two wires to the SENSE and COM terminals Figure 4 Three Wire RTD Connections on One Channel Taking Measurements from Four Wire RTD...

Страница 6: ...re resistance in ohms In this way you can take measurements from RTDs of types that the c FP RTD 122 does not directly support such as 120 nickel RTDs and from resistive devices other than RTDs You ca...

Страница 7: ...RTD types are specified by material composition nominal resistance at 0 C and TCR The c FP RTD 122 can directly measure the temperature of platinum RTDs of either 100 or 1 000 nominal resistance These...

Страница 8: ...arization curves measure the resistance with the c FP RTD 122 and convert the resistance to temperature in the manner suggested by the RTD vendor Three Wire Compensation of Lead Resistance Errors The...

Страница 9: ...00 RTDs and 0 3 C per of mismatch in the lead resistance for 1 000 RTDs For example for 2 leads matched to 5 of each other the lead resistance mismatch is 5 2 0 1 which would cause 0 3 C of error in m...

Страница 10: ...d the inter module communication bus There is no isolation between channels unless otherwise noted If any of the channels on a module are wired at a hazardous potential make sure that all other device...

Страница 11: ...ble gases or fumes Specifications These specifications are typical for the range 40 to 70 C unless otherwise noted Gain error is calculated as a percentage of input signal value Input Characteristics...

Страница 12: ...hannel is updated every 1 08 s Physical Characteristics Indicators Green POWER and READY indicators Weight FP RTD 122 140 g 4 8 oz cFP RTD 122 110 g 3 7 oz Power Requirements Power from network module...

Страница 13: ...2 27 50 g 3 ms half sine 18 shocks at 6 orientations 30 g 11 ms half sine 18 shocks at 6 orientations Safety This product is designed to meet the requirements of the following standards of safety for...

Страница 14: ...ref nsf Mechanical Dimensions Figure 7 shows the mechanical dimensions of the FP RTD 122 installed on a terminal base If you are using the cFP RTD 122 refer to the Compact FieldPoint controller user m...

Страница 15: ...4 8521 Canada Toronto 905 785 0085 Canada Vancouver 514 685 7530 China 86 21 6555 7838 Czech Republic 420 2 2423 5774 Denmark 45 45 76 26 00 Finland 385 0 9 725 725 11 France 33 0 1 48 14 24 24 German...