This document describes how to begin using the NI cRIO-9064.

Safety Guidelines

Caution

 

Do not operate the cRIO-9064 in a manner not specified in this document.

Product misuse can result in a hazard. You can compromise the safety protection
built into the product if the product is damaged in any way. If the product is
damaged, return it to NI for repair.

Safety Guidelines for Hazardous Locations

The cRIO-9064 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous
locations; Class I, Zone 2, AEx nA IIC T4 and Ex nA IIC T4 hazardous locations; and
nonhazardous locations only. Follow these guidelines if you are installing the cRIO-9064 in a
potentially explosive environment. Not following these guidelines may result in serious injury
or death.

Содержание cRIO-9064

Страница 1: ...afety protection built into the product if the product is damaged in any way If the product is damaged return it to NI for repair Safety Guidelines for Hazardous Locations The cRIO 9064 is suitable fo...

Страница 2: ...own to be nonhazardous Table 1 Hazardous Location Retention Accessories Port Required Accessory Part Number USB Device Port NI Locking USB Cable 157788 01 USB Host Port NI Industrial USB Extender Cabl...

Страница 3: ...authority to operate it under your local regulatory rules Caution To ensure the specified EMC performance operate this product only with shielded cables and accessories Special Conditions for Marine...

Страница 4: ...nectors Note Do not install a device if it appears damaged in any way 3 Unpack any other items and documentation from the kit Store the device in the antistatic package when the device is not in use V...

Страница 5: ...on the C Series module 3 Align the C Series module with a slot and seat it in the slot until the latches lock in place Removing C Series Modules Verify that power is not connected to the I O connecto...

Страница 6: ...Use Ring lug Wire 2 1 mm2 14 AWG or larger Screwdriver Phillips 2 What to Do Complete the following steps to ground the cRIO 9064 1 Attach the ring lug to the wire 2 Remove the grounding screw from th...

Страница 7: ...s the POWER LED indicators Table 2 POWER LED Indicators LED Color LED Pattern Indication Green Solid The cRIO 9064 is powered on and the connected power supply is adequate Off The cRIO 9064 is powered...

Страница 8: ...eps to connect the cRIO 9064 to the host computer using the USB device port 1 Power on the host computer 2 Connect the cRIO 9064 to the host computer using the USB A to B cable Caution NI requires the...

Страница 9: ...ring prompts you to do so 2 Enter a unique name for your system in the Hostname field 3 Click the Security Configuration icon 4 Click Login 5 In the Login dialog box enter the username admin and leave...

Страница 10: ...rmat of 172 22 11 x 2 In MAX expand your system under Remote Systems 3 Select the Network Settings tab to configure the IP and other network settings 4 Optional Use the RJ 45 Ethernet port 1 to reconn...

Страница 11: ...ul and appropriate for your application skip to Step 6 4 In MAX expand your system under Remote Systems 5 Select the Network Settings tab to configure the IP and other network settings 6 Reboot the cR...

Страница 12: ...are has been improperly installed on the cRIO 9064 An error can occur when an attempt to upgrade the software is interrupted Reinstall software on the cRIO 9064 Refer to the Measurement Automation Exp...

Страница 13: ...actriodevguide Software Support ni com info swsupport Support ni com support SOFTWARE CompactRIO Sample Projects LabVIEW Create Project HARDWARE NI cRIO 9064 Specifications ni com manuals NI cRIO 9064...

Страница 14: ...nch office websites which provide up to date contact information support phone numbers email addresses and current events Refer to the NI Trademarks and Logo Guidelines at ni com trademarks for inform...