cRIO-9263 Operating Instructions

20

ni.com

CE Compliance

This product meets the essential requirements of applicable 
European Directives, as amended for CE marking, as follows:

Low-Voltage Directive (safety)......... 73/23/EEC

Electromagnetic Compatibility
Directive (EMC) ............................... 89/336/EEC

Note

Refer to the Declaration of Conformity (DoC) for 

this product for any additional regulatory compliance 
information. To obtain the DoC for this product, visit 

ni.com/hardref.nsf

, search by model number or 

product line, and click the appropriate link in the 
Certification column.

Calibration

You can obtain the calibration certificate for the cRIO-9263 at 

ni.com/calibration

.

Calibration interval ........................... 1 year

Содержание CompactRIO cRIO-9263

Страница 1: ...OPERATING INSTRUCTIONS CompactRIO cRIO 9263 4 Channel 10 V 16 Bit Analog Voltage Output Module ...

Страница 2: ...O 9263 only as described in these operating instructions Hot Surface This icon denotes that the component may be hot Touching this component may result in bodily injury Safety Guidelines for Hazardous Locations The cRIO 9263 is suitable for use in Class I Division 2 Groups A B C and D hazardous locations Class 1 Zone 2 AEx nC IIC T4 and Ex nC IIC T4 hazardous locations and nonhazardous locations o...

Страница 3: ...known to be nonhazardous Caution Substitution of components may impair suitability for Class I Division 2 Caution For Zone 2 applications install the CompactRIO system in an enclosure rated to at least IP 54 as defined by IEC 60529 and EN 60529 Special Conditions for Safe Use in Europe This equipment has been evaluated as EEx nC IIC T4 equipment under DEMKO Certificate No 03 ATEX 0324020X Each mod...

Страница 4: ...s performed only by qualified personnel adhering to local electrical standards Caution Do not mix hazardous voltage circuits and human accessible circuits on the same module Caution Make sure that devices and circuits connected to the module are properly insulated from human contact Caution When module terminals are live with hazardous voltages make sure that the terminals are not accessible You c...

Страница 5: ...onnector that provides connections for four analog output channels Each channel has a terminal to which you can connect the positive lead of a voltage signal AO The cRIO 9263 also has common terminals COM that are internally connected to the isolated ground reference of the module Refer to Table 1 for the terminal assignments for each channel ...

Страница 6: ...3 Operating Instructions 6 ni com Table 1 Terminal Assignments Module Terminal Signal 0 AO0 1 Common COM 2 AO1 3 Common COM 4 AO2 5 Common COM 6 AO3 7 Common COM 8 No Connection 9 Common COM 0 1 2 3 4 5 6 7 8 9 ...

Страница 7: ... Connecting a Load to the cRIO 9263 cRIO 9263 Circuitry The cRIO 9263 channels share a common ground that is isolated from the other modules in the CompactRIO system Each channel has a digital to analog converter DAC that produces a voltage signal You must write binary values to the analog output channels Refer to the CompactRIO Bookshelf for more information about converting and calibrating cRIO ...

Страница 8: ...fications section Figure 2 Output Circuitry for One Channel When the module powers on the output channel drives the power on voltage Refer to the Specifications section for more information about power on voltage Refer to the CompactRIO Bookshelf for more information about configuring initial output values in software AO COM cRIO 9263 Amplifier Isolated DAC Overvoltage Short Circuit Protection ...

Страница 9: ...sumption The system thermal dissipation may decrease Refer to the Specifications section for more information about power consumption and thermal dissipation Refer to the CompactRIO Bookshelf for more information about enabling sleep mode in software Specifications The following specifications are typical for the range 40 to 70 C unless otherwise noted Output Characteristics Number of channels 4 a...

Страница 10: ...drive 1 mA per channel min Output impedance 0 1 Ω Accuracy Stability Offset drift 80 µV C Gain drift 6 ppm C Error Percentage of Reading Percent of Range Calibrated max 40 to 70 C 0 35 0 75 Calibrated typ 25 C 5 C 0 01 0 1 Uncalibrated max 40 to 70 C 2 2 1 7 Uncalibrated typ 25 C 5 C 0 3 0 25 Range equals 10 7 V ...

Страница 11: ...age 30 V Short circuit Indefinitely Power on voltage 0 V Update time Reconfigurable Embedded Chassis One channel 3 µs Two channels 5 µs Three channels 7 5 µs Four channels 9 5 µs R Series Expansion Chassis One channel 3 5 µs Two channels 6 5 µs Three channels 9 µs Four channels 12 µs ...

Страница 12: ...s Slew rate 4 V µs Crosstalk 76 dB Settling time 100 pF load to 1 LSB FS step 20 µs 3 V step 10 µs 0 1 V step 8 µs Glitch energy 0x6FFF to 0x7000 110 mV for 2 µs Capacitive drive 1 500 pF min Monotonicity 16 bits DNL 1 to 2 LSBs max INL endpoint 130 LSBs max ...

Страница 13: ...re MTBF specifications at other temperatures or for MIL HDBK 217F specifications Go to ni com hardref nsf and search by model number or product line for more information about MTBF and other product certifications Power Requirements Power consumption from chassis Active mode 625 mW max Sleep mode 25 µW max Thermal dissipation at 70 C Active mode 625 mW max Sleep mode 25 µW max ...

Страница 14: ...3 lb in Weight Approx 150 g 5 3 oz Safety Safety Voltages Channel to COM 11 V max Installation Category I Installation Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage MAINS is a hazardous live electrical supply system that powers equipment This category is for measurements of voltages from specially prot...

Страница 15: ...tion between channels Channel to earth ground Withstand 2 300 Vrms 1 minute max Continuous 250 Vrms Installation Category II Installation Category II is for measurements performed on circuits directly connected to the electrical distribution system This category refers to local level electrical distribution such as that provided by a standard wall outlet for example 115 V for U S or 230 V for Euro...

Страница 16: ... safety for electrical equipment for measurement control and laboratory use EN 61010 1 IEC 61010 1 UL 3111 1 UL 61010B 1 CAN CSA C22 2 No 1010 1 Note For UL and other safety certifications refer to the product label or visit ni com hardref nsf search by model number or product line and click the appropriate link in the Certification column ...

Страница 17: ...C T4 Europe DEMKO EEx nC IIC T4 Environmental CompactRIO modules are intended for indoor use only For outdoor use mount the CompactRIO system in a suitably rated enclosure Refer to the installation instructions for the chassis you are using for more information about meeting these specifications Operating temperature 40 to 70 C Storage temperature 40 to 85 C Ingress protection IP 40 Operating humi...

Страница 18: ...ration To meet these specifications you must panel mount the CompactRIO system and affix ferrules to the end of the terminal wires Operating vibration random IEC 60068 2 64 5 grms 10 to 500 Hz Operating shock IEC 60068 2 27 30 g 11 ms half sine 50 g 3 ms half sine 18 shocks at 6 orientations Operating vibration sinusoidal IEC 60068 2 6 5 g 10 to 500 Hz ...

Страница 19: ...C Part 15A above 1 GHz Immunity Industrial levels per EN 61326 1 1997 A2 2001 Table A 1 EMC EMI CE C Tick and FCC Part 15 Class A Compliant Note For EMC compliance operate this device with shielded cabling FCC Compliance Go to ni com info and enter rdcriofcc for information on using this product in compliance with FCC regulations ...

Страница 20: ...patibility Directive EMC 89 336 EEC Note Refer to the Declaration of Conformity DoC for this product for any additional regulatory compliance information To obtain the DoC for this product visit ni com hardref nsf search by model number or product line and click the appropriate link in the Certification column Calibration You can obtain the calibration certificate for the cRIO 9263 at ni com calib...

Страница 21: ...nited States contact your local branch office Australia 1800 300 800 Austria 43 0 662 45 79 90 0 Belgium 32 0 2 757 00 20 Brazil 55 11 3262 3599 Canada Calgary 403 274 9391 Canada Ottawa 613 233 5949 Canada Québec 450 510 3055 Canada Toronto 905 785 0085 Canada Vancouver 514 685 7530 China 86 21 6555 7838 Czech Republic 420 224 235 774 Denmark 45 45 76 26 00 Finland 385 0 9 725 725 11 France 33 0 ...

Страница 22: ...gal 351 210 311 210 Russia 7 095 783 68 51 Singapore 65 6226 5886 Slovenia 386 3 425 4200 South Africa 27 0 11 805 8197 Spain 34 91 640 0085 Sweden 46 0 8 587 895 00 Switzerland 41 56 200 51 51 Taiwan 886 2 2528 7227 Thailand 662 992 7519 United Kingdom 44 0 1635 523545 ...

Страница 23: ... com are trademarks of National Instruments Corporation Product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the appropriate location Help Patents in your software the patents txt file on your CD or ni com patents ...

Отзывы: