background image

© 2006–2013 National Instruments. All rights reserved. 

372137B-01

Mar13

Refer to the 

NI Trademarks and Logo Guidelines 

at 

ni.com/trademarks

 for more information on National Instruments trademarks. Other 

product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National 
Instruments products/technology, refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on your media, or the 

National Instruments Patents Notice

 at 

ni.com/patents

. You can find information about end-user license agreements (EULAs) and third-party 

legal notices in the readme file for your NI product. Refer to the 

Export Compliance Information 

at 

ni.com/legal/export-compliance

 

for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data.

Where to Go for Support

The National Instruments Web site is your complete resource for technical support. At 

ni.com/support

 you have access to everything from troubleshooting and application 

development self-help resources to email and phone assistance from NI Application Engineers.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway, 
Austin, Texas, 78759-3504. National Instruments also has offices located around the world to 
help address your support needs. For telephone support in the United States, create your service 
request at 

ni.com/support

 and follow the calling instructions or dial 512 795 8248. For 

telephone support outside the United States, visit the Worldwide Offices section of 

ni.com/niglobal

 to access the branch office Web sites, which provide up-to-date contact 

information, support phone numbers, email addresses, and current events.

Содержание 9211

Страница 1: ...erification 3 Accuracy Verification 4 Adjustment 5 Accuracy Adjustment 5 EEPROM Update 6 Re Verification 6 Accuracy Under Calibration Conditions 6 Where to Go for Support 7 Software Calibrating the NI...

Страница 2: ...c information specifications and calibration interval NI DAQmx Readme Operating system and application software support in NI DAQmx LabVIEW Help LabVIEW programming concepts and reference information...

Страница 3: ...set up the NI 9211 1 Install NI DAQmx 2 Make sure the NI cDAQ 9178 power source is not connected 3 Connect the NI cDAQ 9178 to the system safety ground a Attach a ring lug to a 14 AWG 1 6 mm wire b C...

Страница 4: ...and average samples a Create and configure an AI voltage channel according to Table 2 b Configure the AI voltage channel timing according to Table 3 c Start the task d Read samples from the NI 9211 e...

Страница 5: ...of the NI 9211 1 Set the calibrator to Standby mode STBY 2 Connect the NI 9211 to the calibrator as shown in Figure 1 3 Set the calibrator output to 0 07 V 4 Set the calibrator to Operate mode OPR 5 A...

Страница 6: ...adjustment verify that you have met the Test Conditions before returning your device to NI Refer to Where to Go for Support for assistance in returning the device to NI Accuracy Under Calibration Cond...

Страница 7: ...de compliance policy and how to obtain relevant HTS codes ECCNs and other import export data Where to Go for Support The National Instruments Web site is your complete resource for technical support A...

Отзывы: