background image

USER MANUAL

NI 9154

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1)

This document describes the features of the NI 9154 and contains information about mounting
and operating the device.

NI 9154

Hardware
Data

Xilinx

Virtex-5 LX50

MXI-Express

Switch

Downstream

Connection

Upstream

Connection

C Ser

ies

Module

C Ser

ies

Module

Configuring the NI 9154

You can connect the NI 9154 to a MXI-Express host system and configure the powerup
options using a MXI-Express cable.

Connecting One or More NI 9154 Chassis to the MXI-
Express Host System or a Target

Complete the following steps to connect one or more NI 9154 chassis to a MXI-Express host
system or a target.
1.

Make sure the MXI-Express host system is set up and configured as described in the

MXI-Express (x1) Series User Manual

.

2.

If the MXI-Express host system is powered up, power it down.

3.

If the NI 9154 is powered up, power it down.

Содержание 9154

Страница 1: ...g the NI 9154 You can connect the NI 9154 to a MXI Express host system and configure the powerup options using a MXI Express cable Connecting One or More NI 9154 Chassis to the MXI Express Host System...

Страница 2: ...must detect all bus segments on the chassis side in order to configure the PCI hierarchy Powering connected chassis up or down while the host system is running can cause system hangs and data corrupt...

Страница 3: ...OWER USER FPGA1 USER FPGA2 USER FPGA3 LINK LINK UPSTREAM DOWNSTREAM DO NOT SEPARATE CABLES WHEN ENERGIZED IN HAZARDOUS LOCATIONS MXI Express RIO NI 9154 OFF 1 2 1 Power Connector 2 MXI Express Upstrea...

Страница 4: ...ower supplies and accessories are available for the NI 9154 Table 2 Power Accessories Accessory Part Number NI PS 15 Power Supply 24 VDC 5 A 100 120 200 240 VAC Input 781093 01 NI PS 10 Desktop Power...

Страница 5: ...OWNSTREAM DO NOT SEPARATE CABLES WHEN ENERGIZED IN HAZARDOUS LOCATIONS 1 1 CMOS Reset Button CMOS Reset Button The NI 9154 has a CMOS reset button that you can use to reset the CMOS and the BIOS LEDs...

Страница 6: ...f the electrode system of the facility Caution If you use shielded cabling to connect to a C Series module with a plastic connector you must attach the cable shield to the chassis grounding terminal u...

Страница 7: ...that no C Series modules are in the NI 9154 before mounting it Dimensions The following figures show the front and side dimensions of the NI 9154 For detailed dimensional drawings and 3D models visit...

Страница 8: ...top and the bottom of the NI 9154 for air circulation as shown in the following figure Figure 5 NI 9154 Cooling Dimensions 7 6 5 4 3 2 1 8 Cooling Outline 50 8 mm 2 00 in Cooling Outline 50 8 mm 2 00...

Страница 9: ...ent temperature at each side of the NI 9154 63 5 mm 2 50 in from the side and 50 8 mm 2 00 in forward from the rear of the NI 9154 as shown in the following figure Figure 7 NI 9154 Ambient Temperature...

Страница 10: ...unting kit because they are the correct depth and thread for the DIN rail clip Clipping the Device on a DIN Rail Complete the following steps to clip the NI 9154 on a DIN rail 1 2 1 Insert one edge of...

Страница 11: ...ews with the panel mounting kit Tighten the screws to a maximum torque of 1 3 N m 11 5 lb in Note You must use the screws provided with the NI panel mounting kit because they are the correct depth and...

Страница 12: ...ly on a flat rigid surface using the mounting holes in the NI 9154 What to Use NI 9154 M4 screw x2 user provided which must not exceed 8 mm of insertion into the NI 9154 What to Do Complete the follow...

Страница 13: ...rer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certificatio...

Страница 14: ...party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain rel...

Отзывы: