National Instruments 9148 Скачать руководство пользователя страница 21

Waste Electrical and Electronic Equipment (WEEE)

EU Customers

 

At the end of the product life cycle, all NI products must be

disposed of according to local laws and regulations. For more information about
how to recycle NI products in your region, visit 

ni.com/environment/weee

.

Battery Replacement and Disposal

Cd/Hg/Pb

Battery Directive

 

This device contains a long-life coin cell battery. If you need to

replace it, use the Return Material Authorization (RMA) process or contact an
authorized National Instruments service representative. For more information about
compliance with the EU Battery Directive 2006/66/EC about Batteries and
Accumulators and Waste Batteries and Accumulators, visit 

ni.com/environment/

batterydirective

.

电子信息产品污染控制管理办法(中国

RoHS

中国客户

 

National Instruments

符合中国电子信息产品中限制使用某些有害物

质指令(

RoHS

)。关于

National Instruments

中国

RoHS

合规性信息,请登录

ni.com/environment/rohs_china

。(

For information about China RoHS

compliance, go to 

ni.com/environment/rohs_china

.

)

Worldwide Support and Services

The NI website is your complete resource for technical support. At 

ni.com/support

, you have

access to everything from troubleshooting and application development self-help resources to
email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and

other services.

Visit 

ni.com/register

 to register your NI product. Product registration facilitates technical

support and ensures that you receive important information updates from NI.

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the
European Communities using the manufacturer’s declaration of conformity. This system
affords the user protection for electromagnetic compatibility (EMC) and product safety. You
can obtain the DoC for your product by visiting 

ni.com/certification

. If your product supports

calibration, you can obtain the calibration certificate for your product at 

ni.com/calibration

.

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas,
78759-3504. NI also has offices located around the world. For telephone support in the United
States, create your service request at 

ni.com/support

 or dial 1 866 ASK MYNI (275 6964). For

telephone support outside the United States, visit the 

Worldwide Offices

 section of 

ni.com/

niglobal

 to access the branch office websites, which provide up-to-date contact information,

support phone numbers, email addresses, and current events.

20

  | 

ni.com

  | 

NI 9148 User Manual

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание 9148

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...the NI 9148 Figure 1 NI 9148 Front Panel NI 9148 POWER USER FPGA1 STATUS SAFE MODE IP RESET INPUT 19 30 V 20 W MAX LINK 10 100 V C NC C DO NOT SEPARATE CABLES WHEN ENERGIZED IN HAZARDOUS LOCATIONS 2...

Страница 3: ...hed off or the area is known to be nonhazardous Caution Substitution of components may impair suitability for Class I Division 2 Caution For Division 2 and Zone 2 applications install the system in an...

Страница 4: ...e Approved for marine shipboard applications To verify Lloyd s Register certification for a product visit ni com certification and search for the LR certificate or look for the Lloyd s Register mark o...

Страница 5: ...n any orientation on a 35 mm DIN rail or on a panel Use the DIN rail mounting method if you already have a DIN rail configuration or if you need to be able to quickly remove the chassis Use the panel...

Страница 6: ...he serial number from the back of the chassis You will be unable to read the serial number after you have mounted the chassis Caution Make sure that no I O modules are in the chassis before mounting i...

Страница 7: ...PUT 19 30 V 20 W MAX LINK 10 100 V C NC C 2 Fasten the NI 9905 panel to the wall using the screwdriver and screws that are appropriate for the wall surface The maximum screw size is M4 or number 8 Cau...

Страница 8: ...ing of the DIN rail clip Figure 8 One Edge of the DIN Rail Inserted in a Clip 3 2 1 1 DIN Rail Clip 2 DIN Rail 3 DIN Rail Spring 3 Press down firmly on the chassis to compress the spring until the cli...

Страница 9: ...n 1 Make sure that no I O side power is connected to the I O module If the system is in a nonhazardous location the chassis power can be on when you install I O modules 2 Align the I O module with an...

Страница 10: ...a C Series I O module from the chassis 1 Make sure that no I O side power is connected to the I O module 2 Squeeze the latches on both sides of the module and pull the module out of the chassis Conne...

Страница 11: ...the subnet where you want it to be and physically move it to the other subnet Wiring Power to the Chassis The NI 9148 requires an external power supply that meets the specifications in the Power Requi...

Страница 12: ...m flash memory to the FPGA when the chassis powers on Autoload VI on device reboot Loads the FPGA bit stream from flash to the FPGA when you reboot the chassis either with or without cycling power Con...

Страница 13: ...e Notes Configuring DIP Switches Both DIP switches are in the OFF position when the chassis is shipped from National Instruments Figure 12 DIP Switches 1 2 OFF SAFE MODE IP RESET SAFE MODE Switch Safe...

Страница 14: ...define the USER FPGA1 LED to meet the needs of your application The following table lists the USER FPGA1 LED indicators Table 3 User LEDs LED LED Color Description USER FPGA1 Green Yellow Use the LabV...

Страница 15: ...ce may be configured for DHCP but unable to get an IP address because of a problem with the DHCP server Check the network connection and try again If the problem persists contact National Instruments...

Страница 16: ...ion built into the product if the product is damaged in any way If the product is damaged return it to NI for repair Network Network interface 10BaseT and 100BaseTX Ethernet Compatibility IEEE 802 3 C...

Страница 17: ...ry is for measurements of voltages from specially protected secondary circuits Such voltage measurements include signal levels special equipment limited energy parts of equipment circuits powered by r...

Страница 18: ...cations Note Group 1 equipment per CISPR 11 is any industrial scientific or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection an...

Страница 19: ...ndensing Storage humidity IEC 60068 2 56 5 RH to 95 RH noncondensing Pollution Degree IEC 60664 2 Maximum altitude 2 000 m Indoor use only 1 Shock and Vibration To meet these specifications you must p...

Страница 20: ...I is committed to designing and manufacturing products in an environmentally responsible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial to the envir...

Страница 21: ...ngineers Visit ni com services for NI Factory Installation Services repairs extended warranty and other services Visit ni com register to register your NI product Product registration facilitates tech...

Страница 22: ...NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export da...

Страница 23: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: