National Instruments 8234 Скачать руководство пользователя страница 4

©

 National Instruments Corporation

3

Getting Started with the NI 8234

in electrical distribution systems. The following is a description of Measurement (Installation

1

Categories:

Measurement Category I is for measurements performed on circuits 

not

 directly connected to the 

electrical distribution system referred to as MAINS

2

 voltage. This category is for measurements of 

voltages from specially protected secondary circuits. Such voltage measurements include signal 
levels, special equipment, limited-energy parts of equipment, circuits powered by regulated 
low-voltage sources, and electronics.

Measurement Category II is for measurements performed on circuits directly connected to the 
electrical distribution system. This category refers to local-level electrical distribution, such as that 
provided by a standard wall outlet (e.g., 115 V for U.S. or 230 V for Europe). Examples of 
Measurement Category II are measurements performed on household appliances, portable tools, 
and similar products.

Measurement Category III is for measurements performed in the building installation at the 
distribution level. This category refers to measurements on hard-wired equipment such as 
equipment in fixed installations, distribution boards, and circuit breakers. Other examples are 
wiring, including cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation, 
and stationary motors with permanent connections to fixed installations.

Measurement Category IV is for measurements performed at the primary electrical supply 
installation (<1,000 V). Examples include electricity meters and measurements on primary 
overcurrent protection devices and on ripple control units.

Unpacking

The NI 8234 ships in an antistatic package to prevent electrostatic discharge from damaging device 
components. To avoid such damage in handling the device, take the following precautions:

1.

Ground yourself using a grounding strap or by touching a grounded object, such as the computer 
chassis.

2.

Touch the antistatic package to a metal part of the chassis before removing the device from the 
package.

Caution

Never

 touch the exposed pins of connectors.

3.

Remove the device

 

from the package and inspect the device

 

for loose components or any sign of 

damage. Notify NI if the device

 

appears damaged in any way. Do 

not

 install a damaged device

 

into 

the PXIe/cPCIe chassis.

Store the NI 8234 in the antistatic package when not in use.

Installation

The following instructions are for general installation. Refer to the documentation provided by your 
computer manufacturer for specific instructions and warnings. Refer to the 

Specifications

 section for a 

list of the typical power requirements for the NI 8234.

1.

Install the NI Vision Acquisition Software before installing the NI 8234. Refer to the 

NI Vision 

Acquisition Software Release Notes

 for specific installation instructions.

2.

Power off and unplug the PXIe/cPCIe chassis.

1   

Measurement Category is also referred to as Installation Category.

2   

MAINS is defined as the (hazardous live) electrical supply system to which equipment is designed to be connected for the 
purpose of powering the equipment. Suitably rated measuring circuits may be connected to the MAINS for measuring 
purposes.

Содержание 8234

Страница 1: ...erutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In st...

Страница 2: ...later Note Visit ni com info and enter rdvisionvista for more information about National Instruments image acquisition device compatibility with Windows Vista NI Vision Acquisition Software 8 2 1 or...

Страница 3: ...elow the pollution degree stated in the specifications Pollution consists of any foreign matter solid liquid or gas that may reduce dielectric strength or surface resistivity The following is a descri...

Страница 4: ...electrical supply installation 1 000 V Examples include electricity meters and measurements on primary overcurrent protection devices and on ripple control units Unpacking The NI 8234 ships in an anti...

Страница 5: ...unless the handle is in its downward position so that it does not interfere with the injector ejector rail on the chassis as shown in Figure 1 5 Hold the handle as you slowly slide the module into the...

Страница 6: ...34 for acquisition Refer to the Measurement and Automation Explorer Help for NI IMAQdx for more information about how to configure the NI 8234 Note Before configuring the device in MAX ensure that you...

Страница 7: ...ned to meet the requirements of the following standards of EMC for electrical equipment for measurement control and laboratory use EN 61326 EMC requirements Minimum Immunity EN 55011 Emissions Group 1...

Страница 8: ...he FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that m...

Страница 9: ...supports calibration you can obtain the calibration certificate for your product at ni com calibration National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Te...

Страница 10: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: