![National Instruments 73 Series Скачать руководство пользователя страница 27](http://html2.mh-extra.com/html/national-instruments/73-series/73-series_getting-started_3404966027.webp)
Getting Started with NI Integrated Steppers and NI 73xx Motion Controllers
|
© National Instruments
|
27
Step 6: Connect the NI PS-12/13 Power Supply
Note
Do not plug in or turn on the power supply until after you complete
Power on the Drive and Verify Connections
Complete the following steps to connect the power supply to AC input power and to the NI
integrated stepper. Figure 18 shows the power supply terminals.
Figure 18.
NI PS-12/13 Power Supply Terminals
1.
Connect the an AC input cable to the line, neutral, and ground connectors.
2.
Connect the integrated stepper V+ (red) wire to the power V connector.
3.
Connect the integrated stepper V- (black) wire to the power supply -V connector.
4.
Connect the NI UMI power supply ground/common terminal and NI PS-12/13 power
supply ground connections to ensure a common reference.
1
+24 V (NI PS-12) or +4
8
V (NI PS-13) Output
2
+24 V (NI PS-12) or +4
8
V (NI PS-13) Ground
3
AC Input Ground (Protective Earth)
4
AC Input Neutral
5
AC Input Line
L
N
-V
+V
Made in China
+V ADJ
+
OUTPUT: 48V 6.7A
INPUT: 100-240VAC 5A 50/60Hz
L
N
-V
+V
M
a
de in Chin
a
+V ADJ
+
.
1
2
3
4
5