Installation Guide for Comfort Pack (CPE) Units

ENGINEERING SPECIFICATION GUIDE    

      

1.  Product Name

  

National Comfort Products 

 Comfort Pack

2.   Manufacturer 

 National Comfort Products

 

539 Dunksferry Road, Bensalem, PA 19020

 

Phone: (800) 523-7138: 

 

Fax: (215) 639-1674

 

Email:

 [email protected] 

 

Website:

 www.NationalComfortProducts.com

3.   Product  Description

 

Comfort Pack is a SPVU heating and cooling unit designed 

for the multi-family industry. It is self-contained heating and 

cooling thru the wall packaged unit available with gas or 

electric heat. Thru the wall operation saves money and time 

with simple and easy installation, and removes the need for 

long line sets or electrical runs.

  

Models 

CPG – Gas Heat (Natural or LP) w/ Electric Cooling 

 

CPE

 

– Electric Heat w/ Electric Cooling

 

Capacities 

natural gas is not available we offer heating 

packages of 5, 7.5, 10 and 15 KW.

 

Materials 

Cabinet to be constructed of Pre-Painted Galvanized Steel 

Color –

 Neutral tone finish of Tan

  

Voltage  

Factory wired for 230 Volts 1 Phase 60 Hertz and can be 

field adjusted for 208 Volts. Operating voltages are from 

197 to 253 Volts. All CPE ratings are based at 230 Volts.

 

Indoor Air Flow 

Top Supply (outlet), Bottom Return (inlet) (Approved for 

front/open return if local codes apply)(Optional return boot 

available for top return designs) 

 

Filter 

Factory filter easily accessed by thumb screw mounted 

panel w/ filter retainer rod.

 

Slide Out Chassis  

Serviceable slide out cooling section with Coremax 

refrigeration service ports. 5 Speed DC blower motor. 

Evaporator and Condenser Coils shall be fabricated of 

raised lanced aluminum fins mechanically bonded to 

seamless rifled copper tubes.

 

Secondary Drain 

Secondary condensate drain with trap piped to outdoor 

section of unit for drainage thru exterior weep holes 

providing extra protection and indication of primary drain 

blockages. 

Slide Out Furnace (Gas)  

Serviceable slide out gas furnace assembly with stainless 

steel heat exchanger.

 

Sequencing Control (Electric)  

Two stage heat sequencing triac control board.

4.  Technical Data Limitations  

All installations should factor a proper building heat loss/

gain, along with appropriate duct sizing, gas mains and 

riser sizing, and electrical supply wiring to be figured by a 

professional engineer familiar with local and national codes.

5.   Standard Controls & Components 

Equipped to operate with a standard (1H/1C or 2H/1C) low 

voltage thermostat. Factory mounted junction box provided 

for field wiring. 16x25x1 washable air filter. Gas units 

equipped with dual LED diagnostic light. ¾” o.d. primary 
drain connection with flexible tubing provided.

6.   Install 

Recommended installation with CPWS wall sleeve for clean 

finish and future service accessibility. A 29” wide by 29” 

deep open area must be provided unobstructed in front of 

the access panels for chassis and furnace service removal. 

7.  Sales 

Comfort Pack is available thru a variety of wholesalers. 

Contact the factory to help locate a nearby distributor for 

price and availability. 

8.  Warranty 

5 Year warranty on all parts, 5 year warranty on compressor 

and 10 year warranty of the heat exchanger (gas only). 90 

day labor warranty.

9.  Service 

The Comfort Pack is equipped with a slide out cooling 

chassis and a slide out furnace for simple maintenance and 

service. All standard maintenance instructions can be found 

in the installation guides. 

10.  Technical Support 

Factory technical assistance is available to help with any 

concerns or situations regarding the Comfort Pack.

 

Содержание Comfort Pack CPE U Series

Страница 1: ...al Comfort Products A Division of National Refrigeration Air Conditioning Products Inc 539 Dunksferry Road Bensalem PA 19020 215 244 1400 1 800 523 7138 Fax 215 639 1674 CPE U Models Electric Heating...

Страница 2: ...essor page 18 U 11 Wiring Schematic Electric Heat 5 7 10 kw page 19 U 11 Wiring Schematic Electric Heat 15 kw page 20 U 12 Wiring Schematic Electric Heat 5 7 10 kw page 21 U 12 Wiring Schematic Electr...

Страница 3: ...ified by National Codes Attempting to install or repair this unit without such background may result in product damage personal injury or death WARNING Use care when handling scroll compressors Some t...

Страница 4: ...ons are intended as an aid to qualified licensed service personnel for proper installation adjustment and operation of this unit Read these instructions throughly before attempting installation or ope...

Страница 5: ...000Btu 18 18 000Btu 24 24 000Btu 30 30 000Btu A No Grille B Slotted Filter Door C No Grille with Slotted Filter Door Heating Capacity Electric 05 5 Kilowat Kilowatt t 07 7 10 10 Kilowatt 15 15 Kilowa...

Страница 6: ...with the blower The 2nd contactor will be powered after an adjustable time entry factory set for 30 seconds elapses When a call for heat is terminated both all contactors will be de energized U12 Mode...

Страница 7: ...is installed level Masonry walls must have a lintel to support the wall The grille side must be kept free of any obstructions that will reduce or alter the air flow pattern If an optional architectur...

Страница 8: ...AND TURN OFF POWER TO THE UNIT TEMPORARILY SECURE THE CHASSIS POWER AND CONTROL WIRING AND CONNECTORS TO THE TOP OF THE INDOOR COIL COVER TO PREVENT DAMAGE DURING CHASSIS INSTALLATION PLACE THE OUTDOO...

Страница 9: ...e the load imposed by the unit IMPORTANT This Document is customer property and is to remain with this unit Please refer to service information pack upon completion of work to register the unit s warr...

Страница 10: ...e area of the return air opening The support should be high enough to allow for return air provisions to the unit To reduce the possible transmission of sound and vibration a resilient material such a...

Страница 11: ...the secondary drain system This may be done prior to installation of the trap or after 3 Position the trap as shown below and slide the 3 piece of clear flexible about 1 1 2 onto the top end of the tr...

Страница 12: ...s Units installed on the bottom floor should be mounted at least 8 off of the ground The unit is designed and approved for thru the wall installation only The unit must be installed a minimum of 8 abo...

Страница 13: ...duced with the use of these decorative grilles The less resistive these grilles are to air flow the better the units performance will be Outdoor louvers provided by others must be approved by NCP to m...

Страница 14: ...tion drafts from windows doors or other openings leading to the outside exposure to air currents from warm or cold air registers or to exposure where the natural circulation of the air is cut off such...

Страница 15: ...of low voltage wiring from the outdoor unit to the indoor unit and to the thermostat Electrical Low Voltagenit 24 VOLTS WIRE SIZE MAX WIRE LENGTH 18 AWG 150 Ft 16 AWG 225 Ft 14 AWG 300 Ft 13 THERMOSTA...

Страница 16: ...comply with national state and local codes Follow instructions on unit wiring diagram located on the inside of the access door or cabinet and in the wiring diagrams included with the unit LIVE ELECTRI...

Страница 17: ...Installation Guide for Comfort Pack CPE Units High Voltage Diagramsnit 15KW Fuse Box Fuse Sizes 60 Amp 30 Amp Fuse Sizes 5KW 30 Amp 7KW 50 Amp 10KW 60 Amp 5 7 10KW Fuse Box UNIT GROUND UNIT GROUND 15...

Страница 18: ...ended so that extensive servicing can be performed outside the living space This will prevent introducing dirt or doing damage in the living area and could help to eliminate significant disruption of...

Страница 19: ...Installation Guide for Comfort Pack CPE Units Comfort Pack CPE Dimensional Drawing 15 13 16 11 1 16 3 9 16 1 25 32 43 28 1 17 32 7 8 7 11 16 31 7 16 24 OPENING 23 9 16 7 15 16 OPENING 15 16 17...

Страница 20: ...ding between Terminals C R __________ 5 Compressor Winding OHM Reading between Terminals R S __________ 6 Compressor Winding OHM Reading between Terminals C Ground __________ 7 Compressor Winding OHM...

Страница 21: ...Installation Guide for Comfort Pack CPE Units 19 U 11 Wiring Schematic Electric Heat 5 7 10Kw...

Страница 22: ...Installation Guide for Comfort Pack CPE Units 20 U 11 Wiring Schematic Electric Heat 15Kw...

Страница 23: ...Installation Guide for Comfort Pack CPE Units 21 U 12 Wiring Schematic Electric Heat 5 7 10Kw...

Страница 24: ...Installation Guide for Comfort Pack CPE Units 22 U 12 Wiring Schematic Electric Heat 15Kw...

Страница 25: ...34 0 42 5 45 CPE41210 U 208 230 60 1 5 5 26 0 1 3 3 0 1 4 1 8 3 6 47 2 59 0 60 CPE41805 U 208 230 60 1 8 3 44 0 1 3 3 0 1 4 1 8 3 6 25 1 31 4 35 CPE41807 U 208 230 60 1 8 3 44 0 1 3 3 0 1 4 1 8 3 6 3...

Страница 26: ...9 770 45 5 760 46 1 725 48 3 680 51 5 Yellow 2 715 49 0 690 50 7 660 53 0 620 56 5 560 62 5 Blue 3 620 56 5 580 60 4 520 67 3 450 77 8 380 92 1 Black 4 550 63 6 500 70 0 430 81 4 340 103 0 240 145 9 C...

Страница 27: ...41 2 770 41 8 760 42 3 725 44 3 680 47 3 Yellow 2 715 45 0 690 46 6 660 48 7 620 51 9 560 57 4 Blue 3 620 51 9 580 55 4 520 61 8 450 71 4 380 84 6 Black 4 550 58 5 500 64 3 430 74 8 340 94 6 240 134 0...

Страница 28: ...37 7 770 38 2 760 38 7 725 40 6 680 43 3 Yellow 2 715 41 1 690 42 6 660 44 6 620 47 4 560 52 5 Blue 3 620 47 4 580 50 7 520 56 6 450 65 4 380 77 4 Black 4 550 53 5 500 58 8 430 68 4 340 86 5 240 122...

Страница 29: ...780 33 7 770 34 1 760 34 6 725 36 3 680 38 7 Yellow 2 715 36 8 690 38 1 660 39 8 620 42 4 560 47 0 Blue 3 620 42 4 580 45 3 520 50 6 450 58 4 380 69 2 Black 4 550 47 8 500 52 6 430 61 1 340 77 3 240...

Страница 30: ...Orange 5 415 325 225 X X CPE418 Red 1 780 770 760 725 680 Yellow 2 715 690 660 620 560 Blue 3 620 580 520 450 380 Black 4 550 500 430 340 240 Orange 5 415 325 225 X X CPE424 Red 1 780 770 740 705 660...

Страница 31: ...256102 14256103 14256412 14256609 14256600 14256605 14256606 14256140V 14256160 01 14256814 14256811 14256017 14256018 14256159 14256127 14256123 01 14256145 14231012 14231013 14231014 14295022 142300...

Страница 32: ...apacitor 40 5 TXV 14256642 14208305 14208354 14210225 14265026 14225372 14275939 18 18 18 18 18 18 18 CP42 0 U1 0 1 2 3 4 5 6 7 Base Indoor Coil Outdoor Coil Compressor Low Pressure Switch Dual Run Ca...

Страница 33: ...the goods and are in lieu of and exclude all other warranties express or implied arising by operation of law or otherwise including without limitation merchantability and fitness for a particular purp...

Страница 34: ...shall render the warranty void B Compressors In addition to the above referenced requirements Customer is also required to purchase a replacement compressor and return the original compressor to Nati...

Страница 35: ...rifled copper tubes Secondary Drain Secondary condensate drain with trap piped to outdoor section of unit for drainage thru exterior weep holes providing extra protection and indication of primary dr...

Страница 36: ...6 HEATING A C EQUIPMENT NATIONAL COMFORT PRODUCTS National Comfort Products A Division of National Refrigeration and Air Conditioning Products Inc 539 Dunksferry Road Bensalem PA 19020 5908 800 523 71...

Отзывы: