background image

 

 

 

 

 

 

 

 

 

MULTIPLE INPUT UNIT

  

User Guide 

 

 

 

For Technical Assistance

 

Please Phone: (07) 5596 5128

 

 

 

 

 

 

 

 

Содержание MULTIPLE INPUT UNIT

Страница 1: ...MULTIPLE INPUT UNIT User Guide For Technical Assistance Please Phone 07 5596 5128 ...

Страница 2: ...red will cause Message 006 to play Switch 7 when triggered will cause Message 007 to play Switch 8 when triggered will cause Message 008 to play Switch 9 when triggered will cause Message 009 to play Switch 10 when triggered will cause Message 010 to play Switch 11 when triggered will cause Message 011 to play Switch 12 when triggered will cause Message 012 to play Each Switch Trigger will cause t...

Страница 3: ... INTERRUPT an existing Message In this situation a trigger during Message Play will cause the existing Message to STOP and the NEW MESSAGE WILL PLAY The appropriate MIU Triggering Mode is set by REMOVING JUMPER CONNECTORS which are linking PINS that are accessed through a small hole located on the underside of MIU see below Note The Jumpers are not in order To Set MODE 1 Leave all 3 JUMPERS in pla...

Страница 4: ...ESSAGE DETAILS Messages used with MIU should be in MP3 format and written to a 2GB Flash Card supplied with TDU Important Note When a TDU is used with an MIU all messages loaded onto the SD card should have a filename that begins with 3 numbers 001 012 This way TDU knows to play Message Filename 003xxxx when Switch 3 connected to the MIU is triggered Similarly TDU knows to play Message Filename 00...

Страница 5: ...tch must close for a minimum of 100mS to cause MIU to respond Switches can be located up to 100m from the MIU unit or greater than 100m from the MIU if low resistance wiring is used Communication Between the MIU and TDU is achieved via a standard 6 Wire telephone cable A short 6 Wire telephone cable is supplied with the MIU to allow for connection to TDU This cable can be substituted if necessary ...

Страница 6: ...Use this supplied connector to connect to your switches Connections are made by soldering the wires from the switch to the pin positions as indicated on the next 2 pages Note Pins 14 25 are all wired in COMMON to 12V within the MIU This means that if each remote switch has 1 leg wired in common to each other then only 1 switch need have both wires connected back to MIU ...

Страница 7: ...ed Pin 2 Switch 1 Pin 14 Switch 1 Pin 3 Switch 2 Pin 15 Switch 2 Pin 4 Switch 3 Pin 16 Switch 3 Pin 5 Switch 4 Pin 17 Switch 4 Pin 6 Switch 5 Pin 18 Switch 5 Pin 7 Switch 6 Pin 19 Switch 6 Pin 8 Switch 7 Pin 20 Switch 7 Pin 9 Switch 8 Pin 21 Switch 8 Pin 10 Switch 9 Pin 22 Switch 9 Pin 11 Switch 10 Pin 23 Switch 10 Pin 12 Switch 11 Pin 24 Switch 11 Pin 13 Switch 12 Pin 25 Switch 12 ...

Страница 8: ...bligation is solely to repair or replace the product The warrantor is not liable for any incidental or consequential damages due to such defects This Warranty shall not apply to any unit which has been subject to alteration modification abuse negligence accident external voltage lightning surge or used in any manner contrary to these instructions The user is responsible for freight costs to the re...

Отзывы: