SPECIFICATIONS

 

Dimensions (inches) 

4.2  (W)  x 4.2  (D) x 1.7 (H)  

Dimensions (mm) 

106 (W)  x 106 (D) x  43 (H) 

Weight 

6 ounce  or 170g

 

Power Supply 

12V AC or 12V DC Power  

Power Consumption 

Idle -  0.5 W;  Call – 0.75W 

 

Line IN Connector 

RJ 11 6 pin (2  center)

 

Line OUT Connector 

RJ 11 6 pin (2  center)

 

Door Phone Connector 

RJ 45 8 pin (4  center)

 

Power Connector 

2.5mm barrel connector  

FCC & IC COMPLIANT 

Supplier Number NC 

Ringer Equivalence Number  

0.1 REN

 

WARRANTY

 

This device is guaranteed against defects from workmanship for a period of two 
years (24 months) from the date of purchase.  

In the event of a problem, please call ph 800 530 8645 for assistance and if 
necessary, a Return Authorization. You should then return your unit, along with 
the proof of purchase date, and a written statement about the nature of the 
problem.

 

 

The Manufacturers obligation is solely to repair or the product. The product 
may be replaced at the discretion of the Manufacturer. The warrantor is not 
liable for any incidental or consequential damages due to such defects.

 

 

This Warranty shall not apply to any unit which has been subject to alteration, 
modification, abuse, negligence, accident, external voltage/ lightning surge or 
used in any manner contrary to these instructions.

 

 

The user is responsible for freight costs to the repair point. The warrantor will 
be responsible for freight costs in returning this unit back to the user.

 

 

Damage caused to this device or attached equipment by lightning strikes or 
over voltage surge is not covered under this warranty.

 

 

THE CASE IS SEALED AT THE FACTORY. 

 

OPENING THE CASE WILL VOID THE WARRANTY. 

 

Содержание DS1

Страница 1: ...DS1 USER GUIDE For Technical Assistance call the Manufacturers direct ph 0800 530 8645 9AM 5PM West Coast Pacific Time NATCOMM USA LLC Responsible Supplier Code NC ...

Страница 2: ...Page 8 Installation Instructions Pages 9 10 Door Phone Connection Page 11 USA and Canada Compliance Page 12 ADSL Security Alarm Information Page 12 Balance POT Adjustment Page 13 PBX Installation and User Info Pages 14 15 Programming Options and Information Page 16 Programming Procedure Page 17 Troubleshooting Audio Problems Page 18 19 Specifications Pages 20 Warranty Information Pages 20 ...

Страница 3: ...o the DS1 unit They must be connected in parallel with each other Either Door Phone can trigger a Door Phone call If you use TWO Door Phones connected in parallel then Audio will be present at both Door Phones at the same time If you wish to operate 2 completely separate Door Phone zones when using 2 Door Phones you can do so by fitting an additional DS1 Controller on the same telephone line Each ...

Страница 4: ...ory that is available from most retail outlets that sell telephones CORDED TELEPHONES will ALWAYS RING and will alert users of CORDLESS PHONES that do not ring that there is an incoming Door Phone call You can still ANSWER COMMUNICATE and CONTROL LOCKS with CORDLESS PHONES that do not ring Alternative Controllers are available which provide the following features DS1 PSTN connection no lock contro...

Страница 5: ... MOUNT Standard Size 1 Flush mounting door phone standard size 2 Incorporates a low light high resolution CCD colour camera 3 High Quality 316 marine grade stainless steel fascia 4 4 Wire connectivity for Premium audio clarity and volume 5 Capacitive touch switch activation 6 DP4 Dimensions are H 10 4 W 5 2 D 1 4 H 10 4 W 5 2 D 1 4 7 Wall Mount Box WMB3 is supplied to speed up Flush Mount installa...

Страница 6: ...s Model DPC3 for DP4 DP5 Door Phones You can alternatively use one of our Surface Mounting Kits which provides a Rain deflector See below SURFACE MOUNTING KITS Stainless Steel 304 Surface Mounting Kits are available for all Model DP2 to DP5 Door Phones so that your Door Phone can be mounted ONTO a wall surface rather than into it Two separate surface mounting kits are available to cater for the di...

Страница 7: ...DS2 Controller as it has a Call Advise facility This facility alerts you of a Door Phone Intercom call during a real Telephone Line call with Beeps injected into the telephone line With DS2 you can place the real Telephone Call On Hold by pressing on your telephone converse with the visitor at the Door Phone and even open an Electric Door or Gate by pressing You can then return to the real Telepho...

Страница 8: ...Page 8 Natcomm MODEL DS1 INSTALLATION Telephone Line In ADSL Filter if using ADSL Telephone Line Out To All Telephones ...

Страница 9: ...e socket an approved installation technician will need to fit your DS1 direct onto your incoming telephone line immediately ahead of your first telephone socket so that your telephone line connects to all of your telephone sockets through it DS1 has been designed so that it will not interfere with the normal use of your telephone line in any way In the event of a malfunction or power cut your tele...

Страница 10: ...this you should remove the cable from the LINE IN port of DS1 and connect this cable direct to the new LINE OUT socket you will need to remove the existing cable connected to the LINE OUT socket first This will re connect your telephone service 3 Now connect the LINE INPUT port of DS1 to the LINE IN socket using the supplied RJ to RJ telephone cable 4 Connect the LINE OUTPUT port of DS1 to the LIN...

Страница 11: ... Door Phone with the securing screw Model DP2 DP4 or DP5 DOOR PHONES Audio Connection Connect Pins 4 5 the center 2 pins of the 8 pin RJ45 socket of DS1 to the center 2 inputs of the supplied 4 position Phoenix Plug Polarity is not important If you plan to use the interface unit then the terminals for the GREEN and RED wires should be connected to the center 2 positions of the 4 position Phoenix P...

Страница 12: ... Please Note Basic ADSL FILTERS designed for separate connection to each telephone on your line as usually supplied with ADSL modems are not suitable If you are using FIBRE SATELLITE or CABLE for your Internet you will NOT need an ADSL filter USERS WITH DIAL OUT ALARMS DS1 can be used with a DIAL OUT SECURITY ALARM on the same telephone line However to avoid conflict it is ESSENTIAL to fit the DIA...

Страница 13: ...e problems you will need to make slow careful adjustments in one direction or the other until speech can be heard in both directions and without distortion The balance POT is accessed via a small hole on the back of the DOOR PHONE You will need to use a small flat blade screwdriver to adjust it On Models DP 2 5 the balance POT is located under a small plastic sealing plug which will need to be tem...

Страница 14: ...hen be connected to the system controller Once fitted the system will operate exactly as described previously for operation on the selected line 2 ON AN UNUSED TRUNK LINE See Diagram 2 on page 15 Connecting to an UNUSED Trunk of a PBX system DS1 can also be fitted to an UNUSED TRUNK PORT or UNUSED LINE PORT of ANY Multi Line Telephone System This means that this particular line WILL ONLY RING when...

Страница 15: ...of a PBX system Last Line passes through the DS1 Last Line passes through our DS Controller Diagram 2 Connecting to an UNUSED Trunk of a PBX system Important Note Line Input is not required for our DS Controller It outputs Line like conditions for the PBX ...

Страница 16: ...disconnected One user settings is provided to allow NUMBER OF RINGS Allowable Range 01 to 99 rings Default Setting is 10 rings PROGRAMMING NOTES 1 To enter PROGRAMMING MODE you must turn OFF POWER to your unit and then switch POWER ON AGAIN 2 Using ANY TELEPHONE connected to DS1 PRESS within 30 Seconds Note DS1 must be connected to a telephone line 3 You will hear 3 short beeps to confirm you are ...

Страница 17: ... start 1 6 To enter the NUMBER OF RINGS press 1xx where xx number of rings and can be 01 99 for example press 105 for 5 rings for example press 115 for 15 rings 7 TO EXIT PROGRAMMING MODE HANG UP IMPORTANT NOTE After each power up DS1 will prepare to enter programming mode for 30 seconds During this time dial tone is not available You can cancel out of this mode before the 30 second limit and achi...

Страница 18: ...oor Phone may need adjusting as described on page 13 3 If you are still having audio quality problems they can be caused by EMI Electro Magnetic Interference from some Switch Mode Power Supplies and some low end UPS units Uninterruptable Power Supplies Switch Mode Power Supplies can be easily identified because they are very light due to the fact that they do not use a transformer Many brands of t...

Страница 19: ...ser to the DS1 unit so that you can connect it using a temporary new CAT5 cable Please ensure this temporary test cable is no less than 15ft away from your DS1 unit in order to prevent Audio Feedback If satisfactory operation can be achieved you should fault find your problem in the wiring leading to the DOOR PHONE unit 7 If satisfactory operation cannot be achieved you should disconnect the telep...

Страница 20: ...eturn your unit along with the proof of purchase date and a written statement about the nature of the problem The Manufacturers obligation is solely to repair or the product The product may be replaced at the discretion of the Manufacturer The warrantor is not liable for any incidental or consequential damages due to such defects This Warranty shall not apply to any unit which has been subject to ...

Отзывы: