NATCOMM USA LLC

 

Responsible Supplier Code :NC

 

 

DS-SIP

 

SIP INTERCOM CONTROLLER

 

  For Technical Assistance call  

the Manufacturers direct

 

ph 800 530 8645

 

8AM - 5PM

 

West Coast Pacific Time

Содержание DS-SIP

Страница 1: ...NATCOMM USA LLC Responsible Supplier Code NC DS SIP SIP INTERCOM CONTROLLER For Technical Assistance call the Manufacturers direct ph 800 530 8645 8AM 5PM West Coast Pacific Time...

Страница 2: ...plied as a complete kit ready for quick and easy installation by a technician or an end user with some IT experience Description Qty DS SIP Intercom Switch 1 12VDC Power Adaptor 1 CAT5 Network Cable R...

Страница 3: ...a BNC output Marine Grade Stainless Steel face plate Touch Switch operation Blue LED Night illumination Supplied with in wall Wall Mount Box to assist installation Optional Surface Mounting Kit is ava...

Страница 4: ...hones Model DPC3 for DP4 DP5 Door Phones You can alternatively use one of our Surface Mounting Kits which provides a Rain deflector See below SURFACE MOUNTING KITS Stainless Steel 304 Surface Mounting...

Страница 5: ...one detection circuit will automatically terminate the Intercom call after the user hangs up If you have a LOCK MECHANISM fitted you can open a gate or door lock during a call to allow your visitor to...

Страница 6: ...designed for use on PC running Windows 7 or later on your same network Install the program by double clicking the supplied Program file The program will install and a Natcomm Icon will be installed o...

Страница 7: ...The Port Number if different to the default port number 5060 A Different Audio Codec if different to the default codecs Set up a to Static IP address The PBX Network Administrator may advise you to ch...

Страница 8: ...ction Connect Pins 4 5 the center 2 pins of the 8 pin RJ45 socket of DS SIP to the center 2 inputs of the supplied 4 position Phoenix Plug Polarity is not important This is the Audio Pair Also connect...

Страница 9: ...OPENED at any time by calling the DS SIP Extension Number and pressing The Door Gate Lock will remain UNLOCKED for 15 seconds can be 01 99 secs You do not need to receive a call from the Door Phone fi...

Страница 10: ...ated at 12V 1A The polarity of the Relay connection wires is not important Lock 1 should connect to the Brown and Orange terminals Lock 2 or Device 2 should connect to the Blue and White terminals NOT...

Страница 11: ...speech can only be heard in 1 direction Should you encounter one of these problems you will need to make slow careful adjustments in one direction or the other until speech can be heard in both direc...

Страница 12: ...ouncement Note and cannot be used to terminate a call 2 AFTER A FIXED PERIOD OF TIME DS SIP will terminate an Intercom call after a programmable length of time The default connection time for DS SIP i...

Страница 13: ...by Closing as soon as the Intercom is Triggered then you should enter a value of 01 99 in this area this value is the time in seconds that the Relay will remain closed AFTER HANG UP This facility wil...

Страница 14: ...DS SIP switch is connected DS SIP switch will Answer after 1 ring you should hear 1 beep After the beep press you should hear 3 beeps This will take you into program mode 2 Change the settings as per...

Страница 15: ...and IC limits If not installed and used in accordance with these instructions it may be possible that it causes interference to radio communications However there is no guarantee that the interference...

Страница 16: ...ut the nature of the problem The Manufacturers obligation is solely to repair or replace the product The product may be replaced at the discretion of the Manufacturer The warrantor is not liable for a...