1. STOP MODULE Introduction 

 

STOP MODULE (SM) for NERA solar pumps allows to: 

 

Connect PV panels to NERA pump by MC4 PV connectors. 

 

Connect earth protection wires. 

 

Start and stop NERA pump by a push-button. 

 

Start and stop NERA pump by float switch or any other voltage free contact. 

 

Protect NERA pump from voltage spikes. 

 2. Safety Instructions 

The manufacturer strongly suggests to read carefully this operation manual before using and installing its products. Any 
operation (installation, maintenance and repair) must be carried out by trained, skilled  and qualified personnel.  Failure to 
observe and follow the instructions in this manual may result in dangerous and potentially lethal electric shock. 
Pay attention to all standard safety and accident prevention regulations. 
 

 

 

 
 

 

Ensure the complete disconnection from the power supply before any operation 
on the SM itself (including visual inspection) and/or on the NERA PUMP and/or on 
any other device (float switch or pressure switch) connected to the SM. 
Disconnect the SM from the PV panels by removing the PV connectors before 
commencing any work. 
 
Do not remove, for any reason, the cover and the cable plate without having first 
disconnected the device from the power supply and having waited at least 5 
minutes. 
 
SM, PV panels and pumping system must be grounded properly before operation. 
For the entire period SM is power supplied, high voltage is present on the output 
terminals whether or not the pump is running. 
 
Tightening all 4 screws on the cover and cable glands to ensure the ingress 
protection degree. 

 
Avoid any shock or significant impact during transport.  
Check the product immediately upon delivery and check for damage and/or missing parts.  If either occurs, immediately 
notify the supplier. 
Damages due to transport, incorrect installation, or improper use of the device will null and void the warranty.  
Tampering or disassembly of any component will automatically void the warranty. 
The manufacturer cannot be held responsible for any damages to people and/or property due to improper use of its 
products. 
 
 
 

 

Содержание NERA STOP MODULE

Страница 1: ...Installation and operation manual NERA solar pumps STOP MODULE manSM_eng_02 ...

Страница 2: ...2 Index 1 STOP MODULE Introduction 3 2 Safety Instructions 3 3 Technical characteristics 4 4 Electric wiring 5 ...

Страница 3: ...ny other device float switch or pressure switch connected to the SM Disconnect the SM from the PV panels by removing the PV connectors before commencing any work Do not remove for any reason the cover and the cable plate without having first disconnected the device from the power supply and having waited at least 5 minutes SM PV panels and pumping system must be grounded properly before operation ...

Страница 4: ...on degree IP65 NEMA 4 Max Ambient Temperature 50 C 122 F Certifications CE IP65 protection grade is granted with perfect tightness of the cover screws and cable glands It is recommended anyway to protect the SM from the direct exposure to weather and direct sunlight ...

Страница 5: ...5 4 Electric wiring NERA pump output WARNING Respect polarity PV panels input WARNING Not exceed 190 VDC PV panels and NERA pump protection earth ...

Страница 6: ...6 Rocker switch connections Digital input Normally Closed or Normally Open for float switch or pressure switch connection WARNING Use only voltage free contacts ...

Страница 7: ...rl Nastec reserves the right to modify without notice the technical features contained in this manual Nastec srl Via della Tecnica 8 36024 Mossano Vicenza Italy Tel 39 0444 886289 Fax 39 0444 776099 www nastec eu info nastec eu ...

Отзывы: