12
Set Up
Intubatable Head
Intubatable Head
There are individual inflatable lung bags for both
left and right lungs and a separate stomach
bag. Each bag will cause visual chest rise in the
correct anatomical location to indicate effective
and ineffective intubation styles. Jaw thrust is
supported. A manual pulse bulb is included to
simulate a carotid pulse. Features included with
LF04301, LF04302, and LF04302EX.
The unit is not designed for use with mouth-to-
mouth techniques and may contaminate the mouth
and airway. Airway devices are recommended and
the supported devices are listed.
Before using the
simulator for airway
management, lubricate
both the simulator and
supplies being used
with the Pump Spray
Lubricant provided. (See
Figures 21 & 22).
Extreme care should
be exercised when
using a laryngoscope
blade. As with a real
human, (See Figure 23),
damage can be caused
if improper forces and
techniques are used. It
is not recommended to
intubate with dentures
installed. Damaged
caused by improper use
will void the warranty
Note: There is no cricoid.
Laryngoscope Blades
Miller Blades: Size 3
Macintosh Blades: Size 4
BVM – Bag Valve Mask
Adult Size
Oropharyngeal Airway
110 Preferred
100 Smallest acceptable
Endotracheal Tube
7.0mm Preferred
6.5mm Supported
7.5mm Supported
Combitube
37FR Preferred
41FR Supported
LMA Supreme and iGel
Size 3 Supported
Size 4 Preferred
Size 5 Supported
Nasal Trumpet
Size 6 (24FR) Preferred
Size 7 (28FR) Supported
King Airway
Size 3 Supported
Size 4 Preferred
Size 5 Supported
NG Tube, Nasal
Size 16FR Preferred
NG Tube, Oral
Size 16 Preferred
Size 14 Supported
Size 18 Supported
Trachesotomy
Intubation
Uncuffed 6.0mm Preferred
7.0mm Preferred
Cuffed
6.0mm Preferred
7.0mm Preferred
Fig 21.
Fig 22.
Fig 23.
NG Tube, Nasal
Size 16FR
Preferred
Note: Use Nasco Healthcare’s Pump Spray
Lubricant to lubricate airway devices before use.