C. Disinfecting the Airway

To disinfect, repeat the standard cleaning procedure with a

bleach solution, as specified by the Centers for Disease Control.

1.

Fill the system with the solution until it reaches the corners

of the mouth. Remember to start filling with the head flat

and finish with the neck slightly elevated to ensure that the

solution completely fills all airway passages.

2.

Once completely filled with the bleach solution, allow the

head to sit for at least 10 minutes.

3.

Drain as previously described and repeat the rinsing

process to flush out all of the bleach solution. Set the head

aside and allow it to air dry completely prior to next use or

storage.

CAUTIONS

Do not place simulator in contact with any printed paper

or plastic. The ink will transfer and cause an indelible

stain. Similar inks, such as ballpoint pen, will also cause an

indelible stain.

Do not use Nasco Cleaner (LF09919U) around the nose

or mouth of the simulator. The cleaner may be toxic if

ingested.

Properly lubricate the Airway Management head and

intubation appliances.

Use only Nasco Pump Spray Lubricant (LF03644U) with

this simulator. Other lubricants, such as silicone oil, may

cause damage to the airway of the simulator.

Ensure intubation appliances are used accordingly.

Improper use of intubation appliances could damage the

airway of the simulator. Damage to the airway will require

the product to be returned to Nasco for repair.

Ensure trainer and all of the supplies are thoroughly

cleaned and dry prior to storage.

SUPPLIES/REPLACEMENT PARTS

LF03505U

  Tubing Replacement Kit (two 3-ft. lengths 

of clear vinyl tubing, tubing coupling,  

5 pinch clamps, 2 open red caps with  

white adapter, 3 closed red caps with 

2 white adapters)

LF03667U

  “Airway Larry” Airway Management 

Trainer Head

LF03501U

  Rigid Suction Catheter

LF03502U

  Suction Canister

LF03503U

  Gallon Container w/Hand Pump

LF03504U

  Replacement Lungs, set of 2

LF03644U

  Pump Spray Lubricant, 8 oz.

LF03774U

 Thickener

SB52301U

  SSCOR VX2 2310V Variable Regulation Pump

SB52300U

  Universal Power Supply for SSCOR 

Pump 110V-220V

8

Actual product may vary slightly from photo. Nasco Healthcare reserves the right to change product color, materials, supplies, or 
function as needed.

HC190001INM43.indd   8

5/14/19   8:51 AM

Содержание LF03500U

Страница 1: ...HEALTHCARE AdultAirway DecontaminationSimulator LF03500U INSTRUCTION MANUAL WARNING Products may contain dry natural rubber 5 Year Warranty HC190001INM43 indd 1 5 14 19 8 50 AM ...

Страница 2: ...HC190001INM43 indd 2 5 14 19 8 50 AM ...

Страница 3: ...Luke s Medical Center in Milwaukee WI uses suction to enhance first pass success laryngoscopy FPS L with a non anesthetized patient in active emesis FEATURES Airway Larry simulates a non anesthetized patient for practicing intubation ventilation and suction Anatomy and landmarks including teeth tongue oral and nasal pharynx larynx epiglottis arytenoids false cords true vocal cords trachea esophagu...

Страница 4: ...the top of the torso See Figure 1 5 Rotate the head until it is facing up See Figure 2 6 Ensure the squeeze bulb and tubing for manual carotid pulse feature is accessible outside of the case See Figure 3 B Preparing the Fluid System 1 Locate the 3 ft tubing section with the male insert coupling letters G and K in the components list 2 Connect this tubing section to the esophagus with the female bo...

Страница 5: ...the white fitting inside the trachea tubes D Preparing the Simulated Emesis Using the provided gallon container mix the desired amount according to the ratios below 1 quart liter of water to 3 tbsp 45 ml of cellulose 2 quarts liters of water to 6 tbsp 90 ml of cellulose 3 quarts liters of water to 9 tbsp 135 ml of cellulose Note Nasco recommends using distilled water for the mixing procedures Whit...

Страница 6: ...nsure the hand pump is fastened securely 10 Connect the free end of the clear vinyl tubing from the esophagus to the spout end of the hand pump See Figure 6 11 Secure the clear vinyl tubing to the spout end of the hand pump with a small pinch clamp Note Depressing the hand pump allows for approxi mately 1 tbsp 15 ml of simulated emesis per pump E Preparing the Suction System Note This system is de...

Страница 7: ...uth area if stu dents will be applying direct mouth to mouth resuscitation techniques as the cleaner may be toxic if ingested B Cleaning the Airway Management Trainer 1 Disconnect the fluid system 2 Suction any remaining simulated emesis from the Airway Larry head Note Simulated emesis can be reused and stored in the gallon container if desired During storage ensure the cap is on securely Do not s...

Страница 8: ...t head and intubation appliances Use only Nasco Pump Spray Lubricant LF03644U with this simulator Other lubricants such as silicone oil may cause damage to the airway of the simulator Ensure intubation appliances are used accordingly Improper use of intubation appliances could damage the airway of the simulator Damage to the airway will require the product to be returned to Nasco for repair Ensure...

Страница 9: ...nections LF03685U Advanced Airway Larry Airway Management Trainer with Stand LF03830U Adult Intraosseous Infusion Simulator LF03685U LF03672U LF03633U LF03623U Other Available Simulators Copyright 2016 HC190001INM43 ONLINE NascoHealthcare com EMAIL lifeform enasco com PHONE 1 800 431 4310 ADDRESS 901 Janesville Ave Fort Atkinson WI 53538 HC190001INM43 indd 10 5 14 19 8 51 AM ...

Отзывы: