C. Disinfecting the Airway
To disinfect, repeat the standard cleaning procedure with a
bleach solution, as specified by the Centers for Disease Control.
1.
Fill the system with the solution until it reaches the corners
of the mouth. Remember to start filling with the head flat
and finish with the neck slightly elevated to ensure that the
solution completely fills all airway passages.
2.
Once completely filled with the bleach solution, allow the
head to sit for at least 10 minutes.
3.
Drain as previously described and repeat the rinsing
process to flush out all of the bleach solution. Set the head
aside and allow it to air dry completely prior to next use or
storage.
CAUTIONS
•
Do not place simulator in contact with any printed paper
or plastic. The ink will transfer and cause an indelible
stain. Similar inks, such as ballpoint pen, will also cause an
indelible stain.
•
Do not use Nasco Cleaner (LF09919U) around the nose
or mouth of the simulator. The cleaner may be toxic if
ingested.
•
Properly lubricate the Airway Management head and
intubation appliances.
•
Use only Nasco Pump Spray Lubricant (LF03644U) with
this simulator. Other lubricants, such as silicone oil, may
cause damage to the airway of the simulator.
•
Ensure intubation appliances are used accordingly.
Improper use of intubation appliances could damage the
airway of the simulator. Damage to the airway will require
the product to be returned to Nasco for repair.
•
Ensure trainer and all of the supplies are thoroughly
cleaned and dry prior to storage.
SUPPLIES/REPLACEMENT PARTS
LF03505U
Tubing Replacement Kit (two 3-ft. lengths
of clear vinyl tubing, tubing coupling,
5 pinch clamps, 2 open red caps with
white adapter, 3 closed red caps with
2 white adapters)
LF03667U
“Airway Larry” Airway Management
Trainer Head
LF03501U
Rigid Suction Catheter
LF03502U
Suction Canister
LF03503U
Gallon Container w/Hand Pump
LF03504U
Replacement Lungs, set of 2
LF03644U
Pump Spray Lubricant, 8 oz.
LF03774U
Thickener
SB52301U
SSCOR VX2 2310V Variable Regulation Pump
SB52300U
Universal Power Supply for SSCOR
Pump 110V-220V
8
Actual product may vary slightly from photo. Nasco Healthcare reserves the right to change product color, materials, supplies, or
function as needed.
HC190001INM43.indd 8
5/14/19 8:51 AM
Содержание LF03500U
Страница 2: ...HC190001INM43 indd 2 5 14 19 8 50 AM ...