CARE AND MAINTENANCE

• 

 Clean torso when needed using Nasco Cleaner (LF09919U).

• 

 Store in hard carry case in a temperature controlled environment, 

avoiding extreme hot or cold temperatures.

• 

 Replace batteries regularly for optimum working condition.

• 

 It is recommended that batteries are removed when not in use.

• 

 Avoid getting ink on torso simulator or practice boards. Ink will 

transfer indelible stains.

TROUBLESHOOTING

• 

 When preparing to use your SmartScope™ and remote, use 

batteries that are fully charged and installed correctly. 

(See Figure 3.) 

The SmartScope™ is not equipped with a power 

button; this may drain the useful life of your batteries.

• 

 Due to frequency changes, Adult Auscultation Trainer SmartScopes™ with serial numbers 0 to 4999 are only 

compatible with remotes with serial numbers 0 to 4999. SmartScopes™ with serial numbers 5000 and up will 

only work with remotes with serial numbers 5000 and up. The serial numbers are located on the back of the 

device and are handwritten in ink. 

(See Figure 4.)

Figure 3

Figure 4

COMMON CAUSES OF NO SOUNDS

•  Incorrect SmartScope™ placement.

 Move the SmartScope™ slowly over the torso to locate sensors. 

See diagrams on page 5 for placement of sensors. You may apply color-coded dots on the heart and lung sites to 

assist with training.  

•  Ear tips facing the wrong way.

 Verify that the ear tips of the SmartScope™ are facing forward in your ear canal.

•  Battery replacement. 

After installing new batteries, make sure to turn the remote off and back on. This allows 

the remote and SmartScope™ to reset.

Note:

SmartScope™ does not turn off.

•  Battery saver mode. 

The remote will go into battery saver mode if left on the same setting for 8 minutes. 

Sounds will not be heard if the remote is off.

•  Using multiple remotes. 

One remote will operate all SmartScopes™ within 100 ft. simultaneously as long as 

the serial numbers are compatible. Using multiple remotes can cause interference. 

(See Figure 5.)

•  Interference. 

Wireless communication from another transmitter 

using 433 MHz may cause sound selection issues or existing sounds 

to stop or restart. Reset the remote by turning it off briefly, then on again 

and select a different Heart or Lung sound.

•  Connecting an external speaker. 

Insert the jack end of the speaker cord into the top of 

the SmartScope™. 

(See Figure 2.)

•  Using an external speaker. 

When using an amplifier/speaker, no sounds will be heard 

through the SmartScope™ ear tips.

•  Check volume. 

Make sure the volume on the amplifier/speaker is turned up.

Figure 5

AVAILABLE SUPPLIES

LF01144U

  Additional SmartScope™ 

LF01148U

  Replacement Remote Control

LF09919U

  Nasco Cleaner

SB20146U

  Amplified Speaker

First right 

intercostal space

Second left 

intercostal space 

(pulmonic)

Third left 

intercostal space 

(Erb’s point)

Fourth left 

intercostal space

Apex

First left 

intercostal space

Tracheal Site

POSTERIOR LUNG SITES

ANTERIOR HEART AND LUNG SITES

(lower left 

sternum)

Second right 

intercostal space 

(aortic)

Midaxillary

Lower anterior

Actual product may vary slightly from photo. Nasco Healthcare reserves the right to change product 

color, materials, supplies, or function as needed.

HC190001INM47.indd   7-8

6/10/19   1:07 PM

Содержание Life/form LF01142U

Страница 1: ...andSmartScope LF01142U LF01172U INSTRUCTION MANUAL Other Available Simulators LF01220U LF01200U LF03968U LF01220U LF01192U Anterior Auscultation Practice Board with Case and SmartScope LF01200U Deluxe Auscultation Training Station LF01220U Adult Infant Auscultation Training Set LF03968U Deluxe Plus CRiSis Auscultation Manikin LF01992U HC190001INM47 indd 1 2 6 10 19 1 06 PM ...

Страница 2: ...chi Ronchi Ronchi 8 Stridor Stridor Stridor Stridor Lower Volume Stridor Lower Volume 9 Cavernous Cavernous Cavernous Cavernous Cavernous 10 Bronchovesicular Tracheal Bronchovesicular Normal Vesicular Normal Vesicular 11 Bronchial Bronchial Bronchial Normal Vesicular Normal Vesicular 12 Pulmonary Edema Pulmonary Edema Pulmonary Edema Pulmonary Edema Pulmonary Edema 13 Infant Infant Infant Infant I...

Страница 3: ... See diagram on pages 4 5 5 As an alternative an amplified speaker LF01189U included with LF01172U can be used allowing an entire classroom to hear at the same time To connect the speaker plug the speaker cord into the speaker jack on the top of the Smart Scope box See Figure 2 When a speaker is connected to the SmartScope the ear pieces will not work Place the diaphragm of the SmartScope over the...

Страница 4: ...n the remote off and back on This allows the remote and SmartScope to reset Note SmartScope does not turn off Battery saver mode The remote will go into battery saver mode if left on the same setting for 8 minutes Sounds will not be heard if the remote is off Using multiple remotes One remote will operate all SmartScopes within 100 ft simultaneously as long as the serial numbers are compatible Usi...

Страница 5: ...n the remote off and back on This allows the remote and SmartScope to reset Note SmartScope does not turn off Battery saver mode The remote will go into battery saver mode if left on the same setting for 8 minutes Sounds will not be heard if the remote is off Using multiple remotes One remote will operate all SmartScopes within 100 ft simultaneously as long as the serial numbers are compatible Usi...

Страница 6: ... See diagram on pages 4 5 5 As an alternative an amplified speaker LF01189U included with LF01172U can be used allowing an entire classroom to hear at the same time To connect the speaker plug the speaker cord into the speaker jack on the top of the Smart Scope box See Figure 2 When a speaker is connected to the SmartScope the ear pieces will not work Place the diaphragm of the SmartScope over the...

Страница 7: ...chi Ronchi Ronchi 8 Stridor Stridor Stridor Stridor Lower Volume Stridor Lower Volume 9 Cavernous Cavernous Cavernous Cavernous Cavernous 10 Bronchovesicular Tracheal Bronchovesicular Normal Vesicular Normal Vesicular 11 Bronchial Bronchial Bronchial Normal Vesicular Normal Vesicular 12 Pulmonary Edema Pulmonary Edema Pulmonary Edema Pulmonary Edema Pulmonary Edema 13 Infant Infant Infant Infant I...

Страница 8: ...andSmartScope LF01142U LF01172U INSTRUCTION MANUAL Other Available Simulators LF01220U LF01200U LF03968U LF01220U LF01192U Anterior Auscultation Practice Board with Case and SmartScope LF01200U Deluxe Auscultation Training Station LF01220U Adult Infant Auscultation Training Set LF03968U Deluxe Plus CRiSis Auscultation Manikin LF01992U HC190001INM47 indd 1 2 6 10 19 1 06 PM ...

Отзывы: